Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Peavey, modell PV 500

Hersteller: Peavey
Dateigröße: 625.25 kb
Dateiname: df1bc8f4-ec01-4b32-803f-5ff07610145b.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


This is particularly critical for sustained high power applications. If the socket used does not have a ground pin, a suitable ground lift adaptor should be used and the third wire grounded properly. Never break off the ground pin on any equipment. It is provided for your safety. The use of extension cords should be avoided but, if necessary, always use a three-wire type with at least a #14 AWG wire size. The use of lighter wire will severely limit the power capability of this power amplifier. Always use a qualified electrician to install any new electrical equipment. To prevent the risk of shock or fire hazard, always be sure that the amplifier is properly grounded. INSTALLATION AND CONNECTION The PV professional series of power amplifiers is designed for durability in commercial installations and has the quality of performance required in studio and home applications. These units are a standard rack-mount configuration height, and each is cooled by an automatic two-speed internal fan. All input and output connections are on the back panel. Additionally, the level controls and selector switches are on the back panel. The front panel contains LED indicators for power & DDT activation, the mains power switch, and the resetable circuit breaker(s). INDUSTRIAL AND COMMERCIAL INSTALLATIONS For commercial and other installations where sustained high power operation is required, the amplifiers should be mounted in a standard 19" rack. It is not necessary to leave a rack space between each amplifier in the stack since each fan pulls air in from the rear and exhausts the hot air out the front. However, an adequate “COOL” air supply must be provided for the amplifier when rack-mounted. The internal fan must have a source of air that is not preheated by other equipment. The amplifier will start up in low speed fan operation and will normally stay at low speed operation unless sustained high power operating levels occur. Then, as the amplifier “heat sinks” heat up, the automatic thermal sensing circuitry will cause high speed operation to occur. Depending upon signal conditions and amp loading, high speed fan operation may continue or it may cycle continuously between high and low. This situation is quite normal. If cooling is inadequate due to preheated air or a reduction of air flow occurs due to blockage of the amplifier inlet/outlet ports, or if the amplifier is severely overloaded or short circuited, the amplifier thermal sensing system may cause temporary shutdown of the unit. This is indicated by the power LED on the front panel ceasing to illuminate. Depending upon the available cooling air, operation should be restored relatively quickly, and the power LED will be illuminated. In any event, corrective action should be taken to determine the cause of the thermal shutdown. If the amplifier is not severely overloaded or shorted and air flow is normal in and out of the amplifier, then steps should be taken to provide a cooler environment for all the amplifiers. As a general rule, the cooler electronic equipment is operated, the longer its useful service life. STUDIO AND HOME INSTALLATION In most low to medium power applications, the power amplifier can be mounted in any configuration. It is desirable that, if at all possible, the power amplifier be located at the top of an equipment stack. This will prevent possible overheating of sensitive equipment by the hot air rising from the power amplifier. As a general rule, most home and studio requirements will never cause high speed fan operation. However, if they do, this may indicate that you have not taken the necessary steps to provide adequate cooling. Remember, closed up in a cabinet, a PV Series power amplifier will have severe cooling problems, even at low power levels. Again, inadvertent short circuit or sustained overload usage could also cause temporary thermal shutdown and/or tripping of the mains power breaker. Also, most home wiring and electrical circuits are only 15 amps. BRIDGE MODE The Bridge mode on stereo amplifiers is often misunderstood as to the actual operation and usage. In basic terms, when a two-channel amplifier is operated in the Bridge mode, it is converted into a single-channel unit with a Power Rating equal to the sum of both channels’ power ratings at a Load Rating of twice that of the single channel rating. For example, the PV 500 is rated at 250 watts RMS per channel into 2 ohms. The Bridge Ratings are 500 watts RMS into 4 ohms (minimum load). Bridge mode operation is accomplished by placing the mode switch in the “BRIDGE” position, connecting the positive speaker lead to Channel A red binding post, negative 5 speaker lead to Channel B red binding post, and using Channel A as the input channel. All Channel B input functions are defeated, and they serve no purpose now. Another application for Bridge mode operation is to drive sound distribution systems in very large public address applications. In this mode, the PV 500 power ...

Dieses Handbuch ist für folgende Modelle:
Musikinstrumente - PV 500 (625.25 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien