Anleitung Gemini, modell XL-500 II
Hersteller: Gemini Dateigröße: 171.42 kb Dateiname: GMN041.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Congratulations on purchasing a Gemini XL-500 II turntable. This state of CARTRIDGE INSTALLATION: (SEE FIG. 2) the art turntable includes the latest features. Prior to use, we suggest that Because all cartridges have their own designs, please refer to your you carefully read all the instructions. particular cartridge’s instructions to insure proper installation. Features • ±10% Pitch control • Braking for quick stops • Strobe illuminator • Soft-touch start/stop switch Precautions 1. Read all operating instructions before using this equipment. 2. To reduce the risk of electrical shock, do not open the unit. There are NO USER REPLACEABLE PARTS INSIDE. Please contact the Gemini Service Department or your authorized dealer to speak to a qualified service technician. In the U.S.A., if you have any problems with this unit, cal. 1-732-969-9000 for customer service. Do not retur. equipment to your dealer. 3. Tone Arm bearings are factory set and sealed. Any attempt at adjustment will void the warranty. 4. Be sure that all AC power is OFF while making connections. 5. Cables should be low capacitance, shielded and of proper length. Make sure that all plugs and jacks are tight and properly connected. 6. Always begin with the audio level faders/volume controls set at minimum and the speaker volume control(s) set to OFF. Wait 8 to 10 seconds prior to turning up the speaker volume to prevent the transient “POP” that could result in speaker/crossover damage. 7. DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. 8. DO NOT USE ANY SPRAY CLEANER OR LUBRICANT ON ANY CONTROLS OR SWITCHES. Parts Checklist Turntable unit.............................................................................1 Dust cover hinge...........................................................................2 Turntable platter.............................................................................1 45 RPM adapter..................................................................................1 Rubber mat......................................................................................1 Counter balance..............................................................................1 Dust cover..........................................................................................1 Headshell..........................................................................................1 Assembly and Set-Up SEE FIG. 1 ( PAGE 1 ) FOR PART NUMBERS AND LOCATIONS. TURNTABLE INSTALLATION: 1. Set the TURNTABLE BASE (1) on a flat, level surface free of vibration. Try to place the unit as far away from the speakers as possible. Keep the unit away from direct exposure to the sun, heat, moisture or dirt. Keep the unit well ventilated. Use the turntable feet to horizontally stabilize the unit. 2. Make sure that the VOLTAGE SELECTOR (3) switch (located on the TURNTABLE BASE) is set to the correct voltage. WARNING: If you try to operate the turntable with the incorrect voltage setting, it can damage your turntable. 3. After checking to ensure that all packing materials have been removed, gently place the PLATTER (2) on the center spindle of the TURNTABLE BASE (1). 1. Connect the lead wires to the cartridge terminals. For your convenience, the terminals of most cartridges are color coded. Connect each lead wire to the terminal of the same color. White (L+).................................Left Channel + Blue (L-)....................................Left Channel Red (R+)................................Right Channel + Green (R-).............................Right Channel 2. Mount the cartridge in the HEADSHELL (5) and tighten it with the screws included with the cartridge. ATTENTION STANTON 680 CARTRIDGE USERS When using a Stanton 680 or similar cartridge, where the body is grounded to a cartridge terminal, remove the grounding strap from the cartridge body to the cartridge ground terminal. Failure to do this may result in excessive hum. HEADSHELL INSTALLATION: Insert the HEADSHELL (5) into the front of the tubular TONE ARM (6). While holding the HEADSHELL (5) firmly in a horizontal position, turn the LOCKING NUT (7) counter clockwise until the HEADSHELL (5) is locked in place. COUNTERWEIGHT INSTALLATION: (SEE FIG. 3) 1. Slide the COUNTERWEIGHT (8) onto the rear of the TONE ARM (6) with the numbered stylus gauge facing forward. 2. Twist the COUNTERWEIGHT (8) lightly counter clockwise, to screw it onto the rear of the TONE ARM (6). ADJUSTING HORIZONTAL ZERO (0) BALANCE AND STYLUS PRESSURE: 1. Without touching the stylus tip, remove the stylus protector (if your cartridge has a detachable one). 2. Release the ARM CLAMP (9) and lift the TONE ARM (6) off the ARM REST (10). 3. Counter clockwise advancement of the COUNTERWEIGHT (8) will cause the cartridge side of the TONE ARM (6) to be lowered. Clockwise will cause the opposite. Turn the COUNTERWEIGHT clockwise or counter clockwise as needed until the TONE ARM is balanced horizontally. You can easily tell this by watching for th...