Anleitung Zusammenfassung


The fields on this page are populated with information after the panel is connected to an optional NXA-BASE/B Battery Base containing up to two NXT-BP batteries. FIG. 115 Battery Base page This page is ONLY available on Modero Table Top panels (NXT) using an NXA-BASE/B. The elements of the Battery Base page are described in the table below: Battery Base Page Elements Back: Saves the changes and returns you to the previously active touch panel page. Connection Status icon: This visual display of the connection status allows the user to have a current visual update of the panel’s connection status regardless of what page is currently active. • A Lock only appears on the icon if the panel has established a connection with a currently secured target Master (requiring a username and password). Charge Status: Time Remaining (blue) indicates the amount of charge time (use) remaining on the batteries within the connected NXA-BASE/B. Time Until Charged (green) indicates the amount of time remaining until the batteries installed within the connected NXA-BASE/B are fully charged. • Range = 0:00 - 12:59. This is read in HH:MM, hours and minutes. Panel Shutdown: The Panel Shutdown UP/DN buttons alter the timeout value (in minutes). • This value determines the number of minutes that would need to pass before the panel automatically shuts-down. • Once shutdown, the unit would have to be restarted. A zero value disables this feature. Range = 0 - 240, default = 0 min. Low Battery Warning: The Low Battery Warning UP/DN buttons alter the time value (in minutes) available on the battery (for use) before the panel displays a low battery warning. • Range - 10 - 45, default = 15 min. VG-Series Modero Touch Panels Firmware Pages and Descriptions Battery Base Page Elements (Cont.) Very Low Battery Warning: The Very Low Battery Warning UP/DN buttons alter the time value (in minutes) available on the battery (for use) before the panel displays a very low battery warning. This indicates a near-term panel shutdown. Range = 3 - 15, default = 5 min. - This value can never exceed the Low Battery Warning value. • When the NXT-BP batteries (installed within the NXA-BASE/B battery base) reach a point where they need to be recalibrated. - A recalibration pop-up screen appears to ask whether or not you choose to recalibrate the batteries at this time. Battery Status fields: This section provides the ability to monitor the current battery charge levels and charge qualities: • The Combined Charge Status bargraph indicates the combined power charge available from both internal battery connection slots (bargraph range = 0 - 100). • The Battery One Charge Status bargraph indicates the power charge available on the Slot 1 internal battery connection (bargraph range = 0 - 100). • The Battery One Quality bargraph indicates the physical capacity (quality) of the battery. Quality is the percentage of actual capacity vs. its rated capacity. For optimal performance, a battery should be replaced when the quality rating drops below 80%. • The Battery Two Charge Status bargraph indicates the power charge available on the Slot 2 internal battery connection (range = 0 - 100). • The Battery Two Quality bargraph indicates the physical capacity (quality) of the battery. Quality is the percentage of actual capacity vs. its rated capacity. • The Base Version field indicates the firmware version being used by the NXA-BASE/B Battery Base connected to the NXT Modero panel. • The Battery Level Port field indicates the port being used to report the combined charge status level back to the NetLinx Master on (set in TPD4). • The Battery Level field indicates the level being used to report the combined charge status level back to the NetLinx Master on (set in TPD4). Battery Power Brightness Limit: The DISABLE/DISABLED button acts as a power save feature with two available choices: • Disable - activates the brightness limit set on the Modero panel and is used to conserve battery power. Activating this feature causes the panel to function at 80% of full brightness and overrides the Panel Brightness value set on the Setup page. This extends the battery usage time. • Disabled - (illuminated when selected) deactivates this power save feature and makes the panel use the specified Panel Brightness level set on the Setup page. The term "quality" (in the context of a battery), refers to the current capacity relative to the batteries’ rated capacity. For example, after constant use, a battery may be operating at 75% of its rated capacity even though it might be fully charged. In this case, the battery could be incorrectly reporting its’ information back to the battery base and then consequently relating this information back to the Battery Base page. A battery can be recalibrated using an optional NXT-CHG (battery charger). VG-Series Modero Touch Panels Firmware Pages and Descriptions Protected Setup Navigation Buttons The Protected Setup Navigation Buttons (FIG. 116) appear on the ...

Dieses Handbuch ist für folgende Modelle:
Monitore - Modero NXD/NXT-1500VG (4.48 mb)
Monitore - Modero NXD/NXT-1700VG (4.48 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien