Off Timer (On/Off Timer) On, Off (Command : f c) Set days for Off Timer. Transmission [f][c][][Set ID][][Data1][][Data2][Cr] [Data1] 0 (Write), FFH(Read) [Data2] 00H~FFH bit0 : Monday Off Timer On(1), Off(0) bit1 : Tuesday Off Timer On(1), Off(0) bit2 : Wednesday Off Timer On(1), Off(0) bit3 : Thursday Off Timer On(1), Off(0) bit4 : Friday Off Timer On(1), Off(0) bit5 : Saturday Off Timer On(1), Off(0) bit6 :Sunday Off Timer On(1), Off(0) bit7 : Everyday Off Timer On(1), Off(0) Acknowledgement [c][][Set ID][][OK/NG][Data1][Data2][x] * Ignore from bit6 to bit0 when bit7(Everyday) is 1. A19 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 33. On Timer (On/Off Timer) Time (Command : f d) Set On Timer. Transmission [f][d][][Set ID][][Data1][][Data2][Data3][Cr] [Data1] 0 : Monday 1: Tuesday 2 : Wednesday 3 : Thursday 4 : Friday 5 : Saturday 6 : Sunday 7 : Everyday [Data2] 00H~17H (Hours) [Data3] 00H~3BH (Minutes) Acknowledgement [d][][Set ID][][OK/NG][Data1][Data2][Data3][x] *When reading data, FFH is inputted for [Data2], [Data3]. In other cases, all are treated as NG. A20 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 34. Off Timer (On/Off Timer) Time (Command : f e) Set Off Timer. Transmission [f][e][][Set ID][][Data1][][Data2][][Data3][Cr] [Data1] 0 : Monday 1: Tuesday 2 : Wednesday 3 : Thursday 4 : Friday 5 : Saturday 6 : Sunday 7 : Everyday [Data2] 00H~17H (Hours) [Data3] 00H~3BH (Minutes) Acknowledgement [e][][Set ID][][OK/NG][Data1][Data2][Data3][x] *When reading data, FFH is inputted for [Data2], [Data3]. In other cases, all are treated as NG. A21 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 35. Sleep Time (Command : f f) Set Sleep Time. Transmission [f][f][][Set ID][][Data][Cr] Data 0 : Off 1 : 10 2 : 20 3 : 30 4 : 60 5 : 90 6 : 120 7 : 180 8 : 240 (Orderly) Acknowledgement [f][][Set ID][][OK/NG][Data][x] 36. Auto Sleep (Command : f g) Set Auto Sleep. Transmission [f][g][][Set ID][][Data][Cr] Data 0 : Off 1: On Acknowledgement [g][][Set ID][][OK/NG][Data][x] A22 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 37. Power On Delay (Command : f h) Set the schedule delay when the power is turned on (Unit: second). Transmission [f][h][][Set ID][][Data][Cr] Data : 00H ~ 64H (Data value) Acknowledgement [h][][Set ID][][OK/NG][Data][x] • Refer to ‘Real data mapping’ page A7. 38. Language (Command : f i) Set the OSD language. Transmission [f][i][][Set ID][][Data][Cr] Data 0 : English 1 : France 2 : Deutch 3 : Spanish 4 : Italian 5 : Portugues 6 : Chinese 7 : Japanese 8 : Korean 9 : Russian Acknowledgement [i][][Set ID][][OK/NG][Data][x] A23 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 39. DPM Select (Command : f j) Set the DPM (Display Power Management) function. Transmission [f][j][][Set ID][][Data][Cr] Data 0 : Off 1: On Acknowledgement [j][][Set ID][][OK/NG][Data][x] 40. Reset (Command : f k) Execute the Picture, Screen and Factory Reset functions. Transmission [f][k][][Set ID][][Data][Cr] Data 0 : Picture Reset 1 : Screen Reset 2 : Factory Reset Acknowledgement [k][][Set ID][][OK/NG][Data][x] A24 RS-232C Controlling the Multiple Product Transmission / Receiving Protocol 41. S/W Version (Command : f z) Check the software version. Transmission [f][z][][Set ID][][Data][Cr] Data FFH : Read Acknowledgement [z][][Set ID][][OK/NG][Data][x] 42. Input Select (Command : x b) To select input source for the Set. Transmission [x][b][ ][Set ID][ ][Data][Cr] Data 20H : AV 40H : Component 1 41H : Component 2 60H : RGB (PC) 90H : HDMI/DVI (DTV) A0H : HDMI/DVI (PC) Acknowledgement [b][ ][Set ID][ ][OK][Data][x] Data 20H : AV 40H : Component 1 41H : Component 2 60H : RGB (PC) 90H : HDMI/DVI (DTV) A0H : HDMI/DVI (PC) A25 RS-232C IR Codes How to connect Remote Control IR Code Connect your wired remote control to Remote Control port on the Product. Output waveform single pulse, modulated with 37.917KHz signal at 455KHz Carrier frequency FCAR = 1/Tc = fosc/12 Duty ratio = T1/Tc = 1/3 T1 Tc Configuration of frame • 1st frame Lead code Low custom code High custom code Data code Data code C0 C1 C2 C3 C4 C5 C6 C7 C0 C1 C2 C3 C4 C5 C6 C7 D0 D1 D2 D3 D4 D5 D6 D7 D0 D1 D2 D3 D4 D5 D6 D7 • Repeat frame TfRepeat code Lead code 9ms 4.5ms 0.55ms Repeat code 2.25ms 9ms Bit description • Bit "0" • Bit "1" 0.56ms 1.12ms 0.56ms 2.24ms Frame interval : Tf • The waveform is transmitted as long as a key is depressed. Tf Tf Tf=108ms@455KHz A26 RS-232C IR Codes Code(Hexa) Function Note 00 R/C Button 01 R/C Button 02 VOL( ) R/C Button 03 VOL( ) R/C Button 08 POWER ON/OFF R/C Button (Power On/Off) C4 POWER ON Discrete IR Code(Only Power On) C5 POWER OFF Discrete IR Code(Only Power Off) 09 MUTE R/C Button 98 AV R/C Button 0B INPUT R/C Button 0E SLEEP R/C Button 43 MENU R/C Button 5B EXIT R/C Button 6E PSM R/C Button 44 SET R/C Button 10 Number Key 0 R/C Button 11 Number Key 1 R/C Button 12 Number...
Dieses Handbuch ist für folgende Modelle:Monitore - M3702C-BAP (1.78 mb)
Monitore - M3204CCBA (1.78 mb)
Monitore - monitor-M3204CCBA (1.78 mb)