Anleitung Panasonic, modell WVBP110
Hersteller: Panasonic Dateigröße: 264.13 kb Dateiname: WVBP110.PDF
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Be sure to connect grounding lead to the GND terminal. Cautions: 1. Connect this to a 24V AC class 2 power supply only. 2. To prevent fire or shock hazard, the UL listed wire VW-1, style 1007 should be used for the cable for AC 24V Input Terminal. ELC (Electronic Light Control) In this mode a continuously variable electronic shutter is employed to automatically control exposure times in the CCD Image Sensor, according to the incoming light level. With this mode selected, fixed or manual iris lens can be used instead of an ALC type lens. Caution: Under certain unique lighting conditions, the following may appear: • Strong smear and/or blooming on high light objects such as spot lights or windows. • Noticeable flicker on the picture. -6- CONNECTIONS Power Source • WV-BP110 Connect the AC. Power Cord (5) to a electrical outlet of 120V AC 60 Hz. WV-BP114 1. A power supply of 24V AC 60 Hz is required. 2. Connect the power cable to the 24V AC In Terminal (6) on the rear panel of the camera. « W K V. 24V CA ( 19,5V - 28V) 60Hz Recommended wire gauge sizes for 24V AC line. Copper wire size (AWG) #24 (0.22mmJ) #22 (0.33mm*) #20 (0,52mm2) #18 (O^mm’) Length of Cable (Approx.) ft 314 495 842 1403 m 95 150 255 425 Caution: To prevent fire or shock hazard, the UL listed wire VW-1, style 1007 should be used for the cable for AC 24V Input Terminal. Video Cable 1. It is recommended to use a video monitor whose resolution is at least equal to the camera's. 2. Terminate the camera output with 75-ohm resistor at the furthest end of its cable run. • It is recommended to use 75-ohm coaxial cable. • Always set the last monitor's termination switch to 75 ohms, and set the termination switches of intermediate monitors to high impedance (Hi-Z) position. Monitor Monitor • The maximum extensible coaxial cabie length between the camera and the monitor is shown in the table 1. Since cable quality varies among manufactures, verify video quality before final installation if maximum lengths are to be used. Table 1 Type of coaxial cable RG-59/U (3C-2V) RG-6U (5C-2V) RG-11/U (7C-2V) RG-15/U (10C-2V) Recommended maximum cable length (ft) 625 1,650 1,980 2,640 (m) 250 500 600 aoo Wiring precautions: • Do not bend coaxial cable into a curve whose radius is smaller than 10 times the cables diameter. • Never staple the cabte-not even with circular staples. Mismatching will occur. • Never crush or pinch the cable. All of these will change the impedance of the cable and cause poor picture quality. LENSES 1. Selection of Lens ''''''''''■''---^Models Specifications WV-LM4R5A (Wide Angle) WV-LM6B2 (Wide Angle) WV-LM12B2 (Standard) WV-LF4R5C3A (Wide Angle) WV-LF9C3A (Wide Angle) Image Size 1/2" (6.4 (H) x 4.8 (V) mm) 1/3" (4.8 (H) x 3.6 (V) mm) Focal Length 4.5 mm 6 mm 12 mm 4.5 mm 9 mm Maximum Aperture Ratio 1 : 1.4 1 : 1.4 1 : 1.4 1 : 1.2 1 : 1.2 Angular Field of View H 72.6° [56.9°] 56.8° [43.5°] 30.4° [22.8°] 56.4° 29.6° V 56.7° [43.6°] CO CO CO b cn o o 22.8° [17.1°] 43.3° 22.2° Iris Manual Manual Manual Fixed Fixed Focusing Range Adjusted by Camera Mount CS-mount, 1"-32UN Filter Size 037.5 mm, P = 0.5 None None 030.5 mm, P = 0.5 030.5 mm, P = 0.5 Dimensions 01-3/4" x 1-5/8" (044 x 41 mm) 01-11/16‘x 1-9/16’ (043 x 39 mm) 01-11/16“ x 1-9/16“ (043 x 39 mm) 01-3/8" x 1-7/16” (034.4 x 36 mm) 01-3/8" x 1-7/16" (034.4 x 36 mm) Weights 0.20 lbs. (93g) 0.10 lbs. (45g) 0.08 lbs. (35g) 0.06 lbs. (29g) 0.05 lbs. (23g) • [ ]indicates an angle used with the camera WV-BP110 Series. • Dimensions and weights indicated are approximate. • Specifications are subject to change without notice. 2. Mounting the Lens When you use the lens other than listed on page 8, lens mount should be special C-mount (CS-mount 1‘-32UN) and lens weight should be less than 0.99 lbs (450g). If not, both the lens and camera should be secured. The protrusion of the rear of the lens should be as shown below. —n CS-mount : Less than 1/4" {7.2 mm) FOCUS OR FLANGE-BACK ADJUSTMENT The following adjustment should be made by qualified service personnel or system installers. 1. Loosen screws on the flange-back adjusting ring. 2. Turn the flange-back adjusting ring to the desired position. Caution: Do not turn this ring too much to counterclockwise as this could damage the inner glass and CCD image sensor. 3. Tighten the screws on the flange-back adjusting ring. INSTALLATION OF CAMERA • Mounting from the top Remove the mount adaptor from the bottom of the camera as shown. The hole is the standard photographic pan-head screw size (1/4‘ - 20). Make sure that two original screws are used when mounting the mount adaptor; longer type screws may damage inner components. PREVENTION OF BLOOMING AND SMEAR When the camera is faced toward spot light or other bright lights and light reflecting objects, smear or blooming may appear. Therefore, the camera should be operated car...