Anleitung Zusammenfassung


Reset Figure 3 - Grounded plug/reset button Assembly Instructions and Parts List PW132000AV 2 ! IMPORTANT ! This pressure washer is equipped with a microswitch sensitive to water flow. This Instant Start/Stop switch (ISS) senses water flow in the pump. When the trigger is released, water stops flowing through the pump. The ISS then automatically turns the motor off to protect pump from overheating. OPERATION 1. Pull trigger on gun and hold. 2. Turn the “ON/OFF” switch to “ON”. 3. Release trigger. The pressure washer motor will stop running. 4. To spray again, pull trigger and motor and pump will restart. Note: Occasionally the motor may run for a short time to bring fresh, cool water into the pump even if trigger is released. This is part of normal operation and will not damage the unit. Always turn the “ON/OFF” switch to “OFF,” then trigger gun to release hose pressure before unplugging power cord. Risk of equipment damage. Always make sure the “ON/OFF” switch on the unit is “OFF” and unit is unplugged prior to storage. Risk of Injection. Unit will start spraying when trigger is squeezed if on/off switch is in “ON” position. Always point gun in safe direction. ! WARNING ! CAUTION ! CAUTION Call 1-800-330-0712 for Technical Service 3 Assembly Instructions and Parts List PW132000AV 1. Insert short lance into gun and turn clockwise to positive stop. If you experience difficulty, unscrew the large collar on gun. This will allow you to see connection points. 2. Insert adjustable lance into short lance and turn clockwise to positive stop as shown in Figure 4. 3. Ensure that the power switch is in the “OFF” position. 4. Attach the high pressure hose and gun assembly to the unit. 5. Connect garden hose as explained under Garden Hose Connection Instructions. 6. Plug the power cord into a grounded 120V outlet, that is on a dedicated circuit. 7. Turn water on. 8. Depress and hold the trigger on the gun for one minute to release pressure and remove any air trapped in the system. 9. While squeezing the trigger, turn the “ON/OFF” switch to the “ON” position. NOTE: REFER TO PRODUCT MANUAL FOR OPERATING INSTRUCTIONS System Connection Figure 4 - Gun/Lance Connection 13 mm Figure 5 Power Switch High Pressure Outlet Hose Inlet (See Garden Hose Connection page 1) Gun GFCI Plug Assembly Instructions and Parts List PW132000AV Ref. Part No. Description Number Qty. For Replacement Parts, Call 1-800-330-0712 Replacement Parts List Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: The Campbell Group / Parts Dept. 100 Production Drive Harrison, OH 45030 U.S.A. 1 Adjustable Lance PM258000SV 1 2 Short Lance PM258010SV 1 3 Gun PM258020SV 1 4 Nipple Adapter PM248000AV 1 5 Quick Connect Fitting PM248010AV 1 6 Tip Cleaner PM008500AV 1 7 Detergent Applicator PM014700SV 1 8 Hose PM243600AV 1 9 O-ring PM232200SV 3 3 1 9 2 7 8 9 4 5 4 6 Pulverisateur de Lavage Electrique Si’il vous plait lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de proceder a l’entretien du produit decrit. Se proteger ainsi que les autres en observant toutes les instructions de securite, sinon, il y a risque de blessure et / ou degats materials? Conserver ces instructions comme reference. Instructions de Montage et Liste de Pieces de Rechange PW132000AV REMARQUE: SE REFERER AU MANUEL DU PRODUIT POUR TOUTES LES INSTRUCTIONS DE SECURITE © 2003 Campbell Hausfeld 5 Fr IN462300AV 2/03 Specifications Pression Puissance Temperature Max avec du Max. Poids Pouvoir de Lance Capacite Moteur d’Eau du Modele nettoyage Standarde Maximum (Monophase) Tension d’Arrivee Modele PW132000AV 54680 8964 kPa 6,1 L/min 14 A 120V 38° C 15,42 kg Instructions de Montage Branchement du Tuyau d’Arrosage Figure 2 - Branchement de Tuyau d’Arrosage 1. Fixer le raccord intermediaire au raccord d’admission sur le modele (ceci pourrait deja etre fixe a la pompe). 2. Brancher le raccord rapide au tuyau d’arrosage. 3. Tirer le cote “A” du raccord rapide vers le tuyau d’arrosage et le pousser sur le raccord intermediaire. 4. Pousser le cote “A” du raccord rapide vers le raccordement intermediaire et relacher. Tuyau d’arrosage Raccord Rapide Raccord Intermediaire Figure 1 “A” Instructions de Montage et Liste de Pieces de Rechange PW132000AV 6 Fr Cordon 1. Branchez le cordon dans une prise mise a la terre de 120 V et appuyez sur le bouton de reinitialisation tel qu’illustre a la figure 3. 2. ON DOIT LE FAIRE CHAQUE FOIS QU’ON BRANCHE L’UNITE DANS UNE PRISE. Reset Figure 3 - Prise de terre/reinitialisation Reinitialisation ! IMPORTANT ! Ce pulverisateur de lavage est equipe d’un microrupteur sensible au debit d’eau. Cet interrupteur de Marche/Arret Instantane (Instant Start/Stop - ISS) est sensible au debit d’eau dans la pompe. Quand la gachette est lachee, le debit d’eau a travers la pompe s’arrete. Le ISS c...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien