Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Campbell Hausfeld, modell PW1345B

Hersteller: Campbell Hausfeld
Dateigröße: 637.83 kb
Dateiname: 8c2a0bbd-7bdf-47c7-9fcb-7c7f0c19a457.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2. Attach quick connect fitting to garden hose. 3. Pull side “A” of quick connect fitting toward garden hose and push onto nipple adapter. 4. Push side “A” of quick connect fitting towards nipple adapter and release. Figure 2 - Garden Hose Connection Electric Pressure Washer Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. © 2000 Campbell Hausfeld IN459400AV 12/00 Specifications Max Pressure Motor Maximum with Power Inlet Cleaning Standard Maximum (Single Water Unit Model Power Lance Capacity Phase) Voltage Temp. Weight Assembly Instructions Assembly Instructions and Parts List PW1345B NOTE: REFER TO PRODUCT MANUAL FOR ALL SAFETY INSTRUCTIONS Figure 1 PW1345B 2080 1300 psi 1.6 GPM 13 Amps 120V 100°F 25 lbs. For parts, product & service information visit "A" Garden Hose Quick Connect Fitting Nipple Adapter ! IMPORTANT ! This pressure washer is equipped with a microswitch sensitive to water flow. This Instant Start/Stop switch (ISS) senses water flow in the pump. When the trigger is released, water stops flowing through the pump. The ISS then automatically turns the motor off to protect pump from overheating. OPERATION 1. Turn the “ON/OFF” switch to “ON”. 2. Pull trigger on gun to begin spraying water. 3. Release trigger. The pressure washer motor will stop running. 4. To spray again, pull trigger and motor and pump will restart. Note: Occasionally the motor may run for a short time to bring fresh, cool water into the pump even if trigger is released. This is part of normal operation and will not damage the unit. Always turn the “ON/OFF” switch to “OFF” then trigger gun to release hose pressure before unplugging power cord. Risk of Injection. Unit will start spraying when trigger is squeezed if on/off switch is in “ON” position. Always point gun in safe direction. ! WARNING ! CAUTION Call 1-800-330-0712 for Technical Service Power Cord 1. Plug the power cord into a grounded 120V outlet and press the reset button as shown in figure 3. 2. THIS MUST BE DONE EACH TIME THE UNIT IS PLUGGED IN AN OUTLET. Reset Figure 3 - Grounded plug/reset button Assembly Instructions and Parts List PW1345B 2 3 Assembly Instructions and Parts List PW1345B 1. Insert lance into the gun and turn clockwise to positive stop as shown in Figure 4. 2. Ensure that the power switch is in the “OFF” position. 3. Attach the high pressure hose and gun assembly to the unit. 4. Connect garden hose as explained under Garden Hose Connection Instructions. 5. Plug the power cord into a grounded 120V outlet. 6. Turn water on. 7. Depress and hold the trigger on the gun for one minute to release pressure and remove any air trapped in the system. 8. Turn the “ON/OFF” switch to the “ON” position. NOTE: REFER TO PRODUCT MANUAL FOR OPERATING INSTRUCTIONS System Connection Figure 4 - Gun/Lance Connection 13 mm Figure 5 Power Switch High Pressure Hose Outlet Inlet (See Garden Hose Connection page 1) Gun GFCI Plug Assembly Instructions and Parts List PW1345B Ref. Part No. Description Number Qty. For Replacement Parts, Call 1-800-330-0712 Replacement Parts List Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: The Campbell Group / Parts Dept. 100 Production Drive Harrison, OH 45030 U.S.A. 1 Adjustable Lance PM235800SV 1 2 Short Lance PM235900SV 1 3 Gun/Hose PM230300SV 1 4 Nipple Adapter PM022100AV 1 5 Quick Connect Fitting PM020600SV 1 * 6 Tip Cleaner PM008500AV 1 7 Detergent Applicator PM014700SV 1 * 8 Tool Box Lid HV601500SV 1 * 9 Tool Box Tub HV601600SV 1 * Optional equipment, may not be supplied with all models. 3 1 2 6* 7 8* 9* 4 4 5 Pulverisateur de Lavage Electrique Si’il vous plait lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de proceder a l’entretien du produit decrit. Se proteger ainsi que les autres en observant toutes les instructions de securite, sinon, il y a risque de blessure et / ou degats materials? Conserver ces instructions comme reference. Instructions de Montage et Liste de Pieces de Rechange PW1345B REMARQUE: SE REFERER AU MANUEL DU PRODUIT POUR TOUTES LES INSTRUCTIONS DE SECURITE © 2000 Campbell Hausfeld 5 Fr IN459400AV 12/00 Specifications Pression Puissance Temperature Max avec du Max. Poids Pouvoir de Lance Capacite Moteur d’Eau du Modele nettoyage Standarde Maximum (Monophase) Tension d’Arrivee Modele PW1345B 54680 8964 kPa 6,1 L/min 13 A 120V 38° C 11,3 kg Instructions de Montage Branchement du Tuyau d’Arrosage Figure 2 - Branchement de Tuyau d’Arrosage 1. Fixer le raccord intermediaire au raccord d’admission sur le modele (ceci ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien