Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Karcher, modell HD 7/10-4 M

Hersteller: Karcher
Dateigröße: 628.18 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• After use immerse filter in clean water. Turn metering valve to maximum cleaning agent concentration setting. Start unit and rinse through for one minute. Interrupting the operation • Release lever of the handgun, the unit switches off. Retract lever again and the unit switches on again. Switching the unit off • Set unit switch to "0" and pull out power plug. • Close water inlet. • Retract lever until the unit is without pressure. • Actuate the handgun's safety catch to secure the handgun lever from accidentally being triggered. Transporting the cleaner • To transport the appliance over long distances use the push handle to pull the appliance. • When carrying the appliance always use the handle, not the push handle. • Prior to a transport in the horizontal position remove the detergent bottles from the bottle holder and close them. English Storing the cleaner • Place the handgun in the support. • Reel in the high-pressure hose and hang it over the hose rest. or • Wind the high-pressure hose on to the hose reel. Push in the crank handle to lock the hose drum. • Wind the connection cable around the cable holder. • Fix the plug using the installed clip. Frost protection Caution! Frost will destroy a unit that is not completely empty of water! Store the unit where it will be free of frost. If storage away from frost is not possible: • Drain off the water and rinse the unit through with anti-freeze. • Leave the unit to dry for max. 1 minute. • Use the standard glycol-based anti-freezes for cars. • Follow the handling instructions of the antifreeze manufacturer. Care and maintenance ! Danger! Before any care and maintenance work on the unit draw out the mains plug. Caution! When changing the oil, dispose of any waste oil only at authorised collection points. Safety inspection/Maintenance contract You can arrange with your dealer to have a regular safety inspection carried out or to have a maintenance contract. Please seek advice. Before each use • Check connecting cable for damage (risk of getting an electric shock), have a damaged connecting cable replaced without delay by authorised Customer Service personnel or an electrician. • Check high-pressure hose for damage (danger of explosion), replace a damaged high-pressure hose without delay. • Check unit (pump) for any leaks. Three drops per minute are allowable and can appear on the underside of the unit. Seek the help of Customer Service if leaks are more serious. Every week • Check oil level in oil reservoir: if the oil is milky (water in oil), seek the help of Customer Service immediately. • Clean the strainer in the water connection. • Clean the filter at the suction hose for detergent. Annually or after 500 operating hours • Change the oil – For oil quantity and type see Technical Specifications. – Undo the fastening screw, remove the hood, remove the oil tank cover, tilt unit. – Drain oil into a suitable container. – Fill slowly with fresh oil; air bubbles have to escape. – Attach the oil tank cover. Troubleshooting ! Danger! Before any repair work is undertaken, switch the unit off and pull out the power plug. Have electrical components checked and repaired only by authorised Customer Service personnel. For faults which are not identified in this chap English ter, or when in doubt or when expressly instructed to do so, consult authorised Customer Service personnel. Unit does not work • Check connecting cable for damage. • Check the mains voltage. • Consult Customer Service if there is an electrical fault. Unit does not come up to pressure • Set nozzle to "high pressure". • Clean/replace nozzle. • Evacuate air from the cleaner (see Switching on the unit). • Clean the strainer in the water connection. • Check water inlet volume (see Technical Specifications). • Check all supply lines to the pump for leaks or obstructions. • Seek the help of Customer Service if necessary. Pump is leaky • Three drops per minute are allowable and can appear on the underside of the unit. Seek the help of Customer Service if leaks are more serious. Pump makes a knocking noise • Check all supply lines as well as the detergent system for leaks. • Close the cleaning agent metering valve when running the unit without cleaning agent. • Evacuate air from the cleaner (see Switching on the unit). • Seek the help of Customer Service if necessary. Detergent is not being drawn in • Set nozzle to "Chem". • Check detergent suction hose with filter for leaks or obstructions and clean it if necessary. • Open detergent metering valve or check it for leaks/remove obstruction. • Seek the help of Customer Service if necessary. Spare parts You will find a list of spare parts at the end of these operating instructions. Warranty The warranty terms issued by our authorised marketing company are valid in every country. We remedy any fault in the unit free of charge within the warranty period providing the cause of the fault proves to be a material or manufacturing error. The warranty only becomes oper...

Dieses Handbuch ist für folgende Modelle:
Hochdruckreiniger - HD 6/13-4 M (628.18 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien