HOW TO USE SPRAY WAND: Your pressure washer is equipped with a multi-adjustable spray wand with both high and low pressure settings. The high pressure setting is for cleaning and rinsing, the low pressure setting is for applying chemicals or cleaning solutions to surfaces. When using the high pressure setting, DO NOT allow the jet-like spray to come in contact with unprotected skin, eyes, or with any pets or animals. Serious injury can occur. Risk of injection or injury to person. DO NOT direct discharge stream toward persons. For high pressure operation, pull back the nozzle of the multi-adjustable spray wand as shown. . 10- ENG The nozzle at the end of the multi- adjustable spray wand can be rotated to change the high pressure spray pattern from a narrow jet to a 40. fan shape, as shown. Markings have been placed on the nozzle to help you select the spray pattern. 40. fan spray narrow jet stream For low pressure operation, extend the nozzle of the multi-adjustable spray wand as shown. HOW TO APPLY CHEMICALS AND CLEANING SOLVENTS Applying chemicals or cleaning solvents is a low pressure operation. NOTE: Use only soaps and chemicals designed for pressure washer use. Do not use bleach. To Apply chemicals: 1. Press chemical hose onto barbed fitting located near high pressure hose connection of pump as shown. Barb fitting 2. Place other end of chemical hose with filter on it into container holding chemical/cleaning solution. NOTE: The chemical/water ratio is 7:1, for every 7 gallons of water pumped 1 gallon of chemical/cleaning solution will be used. 3. Install low pressure (black) nozzle into quick connect fitting of spray wand, see How To Use Spray Wand paragraph in this section. 4. After use of chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. If chemicals remain in the pump it could be damaged. Pumps damaged due to chemicals will not be covered under warranty. NOTE: Chemicals and soaps will not siphon when spray wand is in the high pressure setting. TO SHUT DOWN IMPORTANT: Read and understand how to shut down the pressure washer before operating. 1. If you have applied chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. NOTE: Failure to do so could cause damage to the pump. 2. Turn engine off by placing the throttle control in the OFF position. NOTE: NEVER turn the water off with the engine running. 3. Turn the fuel valve to the OFF position if engine will not be restarted soon. 4. Turn water source off. 5. Pull trigger on spray gun to relieve any water pressure in hose or spray gun. 6. See Storage section in this manual for proper storage procedures. 11- ENG . BEFORE STARTING Read and understand all Important Safety Instructions in the front of this manual and the following Cautions and Warnings before starting the pressure washer. • Never fill fuel tank completely. Fill tank to 1/2" below bottom of filler neck to provide space for fuel expansion. Wipe any fuel spillage from engine and equipment before starting engine. • Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank. • Never run engine indoors or in enclosed, poorly ventilated areas. Engine exhaust contains carbon monoxide, an odorless and deadly gas. • Never turn water supply off while pressure washer engine is running or damage to pump will result. • DO NOT use hot water, use cold water only. • DO NOT stop spraying water for more than two minutes at a time. 1. In a well ventilated outdoor area add fresh, high quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to Engine Owners Manual for correct procedure. 2. Remove filler cap/dipstick and add engine oil (supplied) to engine. NOTE: There will be a slight amount of oil in the engine from factory testing. Always check oil level before each start-up. Filler cap/dipstick 3.Verify the filter screen is in water inlet of pump. NOTE: Cone side faces out. Filter Screen 4. Connect high pressure hose to pump outlet. 5. Connect water source to pump inlet. NOTE: Water source must provide a minimum of 5 gallons per minute at 20 p.s.i. Water Source High Pressure Hose 6. If you are applying a chemical or cleaning solution, See How To Siphon Chemicals/Cleaning Solvents in Operation section of this manual. 7. Turn water source on. NOTE: Failure to do so could cause damage to the pump. . 12- ENG 8. Turn fuel valve to the ON position, 1/4 turn counterclockwise. 9. Move the choke control lever to the CHOKE ON position and the throttle control to the FAST position. NOTE: No choke is needed to start a warm engine. Fuel Valve Knob Choke Control Throttle Control 10. Pull starter grip slowly until you feel resistance, then pull briskly. Return starter grip gently. Pull rope with a rapid ...
Dieses Handbuch ist für folgende Modelle:Hochdruckreiniger - 919.769062 (784.43 kb)