Anleitung Delta, modell DT2400CS
Hersteller: Delta Dateigröße: 567.31 kb Dateiname: 3a454ebf-8e8f-4cff-9ab8-6edeffd88fc5.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
5. Disconnect spark plug wire. 6. Connect 36 inch length of hose to water inlet of pump. 7. Add *RV antifreeze to hose as shown. 8. Pull engine starter rope slowly several times until antifreeze comes out of high pressure hose connection of pump. 9. Remove short hose from water inlet of pump. 10. Reconnect spark plug wire. *Windshield washer fluid may also be used 19- ENG D27918 DUAL TANK CLEANING SYSTEM 1. Turn control valve knob to the down (off) position. Control Valve Knob 2. Remove cleaning solution hose at chemical injector and pull through rear shroud. 3. Place end of cleaning solution hose into a suitable container to drain cleaning solution. 4. Turn control valve toward tank to be drained. 5. Repeat steps 3-4 to drain second tank. 6. Turn control valve knob to the down (off) position. 7. Fill tanks with clean water. 8. Turn valve toward tank and drain water from tank. Repeat on second tank. NOTE: This will rinse cleaning solution tanks. 9. Feed cleaning solution hose between shroud and wheel bracket making sure it is routed over the axle as shown. Reconnect cleaning solution hose to chemical injector for future use. Axle Hose D27918 20- ENG TROUBLE SHOOTING GUIDE CAUSE CORRECTION PROBLEM Add Fuel. No fuel. Engine will not start (see Engine Pressure builds up after two pulls Squeeze gun trigger to relieve on the recoil starter or after initial pressure. Manual for use. further engine troubleshooting) Move choke to the “Choke” position. Choke lever in the “No Choke” position. Spark plug wire not attached. Attach spark plug wire. Choke lever in the “Choke” Move choke to the “No Choke” position on a “hot” engine or an position. engine that has been exposed to thermal heat for a long period of time. No or low See How to Use Spray Wand Wand not in high pressure. pressure paragraph in the Operation (initial use) Section. Water supply must be at least 5 GPM @ 20 PSI. Leak at high pressure hose fitting. Low water supply. Tighten fitting. Apply sealant tape if necessary. Nozzle obstructed. See Spray Wand paragraph in the Maintenance section for the correct procedure. Water filter screen clogged. Remove and clean filter. Defective E-Z start valve. Check with Authorized Warranty Service Center (AWSC.) Air in hose. Turn off the engine, then the water source. Disconnect the water source from the pump inlet and turn the water source on to remove all air from the hose. When there is a steady stream of water present, turn water source off. Re-connect water source to pump inlet and turn on water source. Squeeze trigger to remove remaining air Choke lever in the “Choke” position. Move choke to the “No Choke” position. Throttle control lever is not in the Move throttle control lever to the “Fast” position. “Fast” position. High pressure hose is too long. Use high pressure hose under 100 feet. 21- ENG D27918 PROBLEM CAUSE CORRECTION Will not draw cleaning solution Wand not in low pressure. Screen on end of chemical injector rinsing hose not in water Cleaning solution too thick. Pressure hose is too long Cleaning solution build up in chemical injector. Filter clogged on chemical injector rinsing hose. Hoses are not connected. Control valve is in the down (off) position or pointed toward the tank not being uses. See How to Use Wand paragraph in the Operation Section. Clean filter. Dilute cleaning solution. Cleaning solution should be the same consistency as water. Have parts cleaned or replaced by AWSC. Make sure end of chemical injector rinsing hose is fully submerged into clean water. Make sure all hoses are connected at valve. Turn control valve toward tank being used. Lengthen water supply hose instead of high pressure hose. No or low Worn seal or packing Have replaced by AWSC. pressure (after period of Worn or obstructed valves. Have replaced by AWSC. normal use) Worn unloader piston. Worn E-Z start valve. Have replaced by AWSC. Have replaced by AWSC. Water leaking at gun/wand connection Loose hose connection. Worn or broken o-ring. Check and replace. Tighten. Water leaking Loose connections. Tighten. at pump Piston packings worn. Worn or broken o-rings. Pump head or tubes damaged from freezing. Have replaced by AWSC. Have replaced by AWSC. Have replaced by AWSC. Pump Pulsates Nozzle obstructed. See Spray Wand paragraph in the Maintenance section for the correct procedure. D27918 22- ENG NOTES 23- ENG D27918 WARRANTY DELTA MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and generators, which have the following warranty periods: 3 YEARS - Limited warranty on 2-stage oil-free air compressor pumps that operate at 1725 RPM. 2 YEARS -Limited warranty on oil-lubricated air compressor pumps. 1 YEAR -Limited warranty on all other air compressor components. 2 YEARS -Limited warranty on electric generator alternators. 1 YEAR - Li...