Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Graco Inc., modell Hydra-Clean 2510

Hersteller: Graco Inc.
Dateigröße: 934.96 kb
Dateiname: 162344d5-4c6d-46cc-b994-70544ef83ef5.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Box 1441 MINNEAPOLIS, MN 55440-1441 @COPYRIGHT1991. GRACO INC. ~A~~~~~ HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. Read and understand allinstruction manuals before operating equipment. FLUlD 1NJECTlON HAZARD General Safety This pressure washer generates very high fluid pressure. Spray from the gun, leaks or tuptured components can inject fluid through your skin and into your body and cause extremelyserious bodily injuryincluding the need for amputation. Also, fluid injected or splashed into the eyes or on the skin can cause serious damage. NNERpoint the spray gun or wand at anyone or at anypart of the body.NNER put hand or fingers over the spray tip. ALWAYS follow the Pressure Relief Procedure,before cleaning or servicing any part of the sprayer. NNER try to stop or deflect leaks with your hand or body. Be sure equipment safety devices are operatingproperly before eachuse. Medical Treatment If any fluid appears to penetrate your skin, get EMERGENCY MEDICALTREATMENTATONCE.DO NOT TREAT ASA SIMPLE CUT. Tell the doctor exactlywhat fluid was injected. NOTE TO PHYSICIAN injection inthe skin is a traumatic injug It Is Important to treat theInJury surgically as soon as possible. Do not delay treatment to research toxiciv. Toxicify is a concern with .some exotic- coatings injected direct& into thebloodstream. Consultationwirb a plastic surgeon or reconstructive hand surgeon may be advisable. Pressure Relief Procedure To reduce the riskof serious bodily injury, including fluid injection and splashing in the eyes or on the skin, always follow this procedure whenever you stopspraying for more than 10 minutes, when shutting down, and before checking or repairing any part of the system. 1. Engage the trigger safety latch. 2. Thm the sprayeroff. 3. Disconnect the electrical supply. 4. Shut off the water supply. 5. Disengage the trigger safetylatch and trigger the gun to relieve pressure, and then engage the triggersafety latch again. 6. Before long-term (ovemighi) storage, disconnect the water supply and disconnect the electricity. Spray Gun Safety Devices Be sure all gun safety devices are operating properlybefore eachuse. Do not remove or modity any part of the gun; this can cause a malfunction and result in serious bodily injury. SAFEIY LATCH: Whenever you stop spraying for a moment, always set the gun safety latch in the engagedor"safe" position, making thegun inoperative. Failureto properly set the safety latch can result in accidental triggering of the gun. SPRAY TIP SAFm. Use extreme caution when cleaning or changing spray tips. If a spray tip clogswhile spraying, engage the gun safety latch immediately. ALWAYS follow the Pressure Relief Procedure and then remove the spray tip to clean it. 2 308-535 GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of DANGER -1 Improper connection of the equipment-grounding conductor can result in the risk of electrocution. electric shock. This equipment is equipped with a cord Check with a qualified electrician or service having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and &dunbed in accordance wiih all local codes and ordinances. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, connect this pressure washer to a circuit that is protected by a ground-fault circuit-interrupter(GFCI). EQUIPMENT MISUSE HAZARD General Safety Any misuse of the pressure washer or accessories, such as overpressurizing, modifying parts, usingincompatible chemicals and fluids,or using worn or damaged parts, can cause them to rupture and result in fluid injection, splashing in the eyes or on the skin, or other serious bodily injury, fire, explosion or propertydamage. NNER alter or modifyany part of this equipment; doing so could cause it to malfunction. CHECK all spray equipment regularly and repair or replace worn or damaged parts immediately. ALWAYS wear protective eyewear and appropriateclothing. If using a chemical injector, read and follow the chemical manufacturer's literature for recommendations on additional protective equipment, such as a respirator. System Pressure This sprayer can develop high operating pressure. Be sure that all spray equipment and accessories are rated to.withstand the maximum working pressure of this sprayer. DO NOT exceed the maximum working pressure of any component or accessory usedin the system. Chemical Compatibility BE SURE that all chemicals used in the chemical injector are compatible with the wetted parts of the hose, gun, wand and tip, as given in the Technical Data (inside back cover). Always read the chemical manufacturer's literature before using any chemical in this pressure wa...

Dieses Handbuch ist für folgende Modelle:
Hochdruckreiniger - Hydra-Clean 3009 (934.96 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien