Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Belshaw Brothers, modell TG 50

Hersteller: Belshaw Brothers
Dateigröße: 6.89 mb
Dateiname: d5cd2c28-b50e-4b67-9881-c47feef6ad88.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


1750 22nd Avenue South Seattle, WA 98144-4590 Phone: (206) 322-5474 • Fax: (206) 322-5425 Toll Free: 1-800-578-2547 Email: service@belshaw.com • Congratulations on buying a new Thermoglaze from Belshaw Bros., Inc. Please inspect the unit carefully for damage or missing pieces immediately after receiving your system. Belshaw cannot pay for shipping damage, because the freight company has accepted the machine from Belshaw in good condition, and is responsible for its safe delivery. For your protection, each crate should be inspected before signing the Bill of Lading to report any visible damage caused by the trucker in transit, and account for the number of crates. EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine. Purchased by _____________________________________________________________________ Installed by ______________________________________________________________________ Date of Installation ________________________________________________________________ Model number ___________________________________________________________________ Serial number 0805 MN-1716EN Belshaw Bros., Inc. 1750 22nd Avenue South Seattle, WA 98144-4590 Phone: (206) 322-5474 • Fax: (206) 322-5425 Toll Free: 1-800-578-2547 Email: service@belshaw.com • Contents 1 Unloading and Uncrating 1 2 Identification 2 3 Installation 4 4 Assembly 5 5 Operation 8 6 Cleaning 9 7 Maintenance 22 8 Troubleshooting 23 9 Appendix 27 Belshaw Bros., Inc. • 1750 22nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 Thermoglaze 50 MN-1716EN Preface The operator of the Thermoglaze is expected to behave safely, read this manual before operation, and follow its instructions and warnings. Study the instructions and warnings in this manual carefully before operating the equipment. A thorough understanding of how to install, maintain, and safely operate the Thermoglaze will prevent production delays and injuries. Prior operation of the equipment before reading and understanding the instructions in the manual will void the warranties of the equipment. To use the Thermoglaze safely, heed the following warnings and all other warnings that appear in this manual: • To avoid damaging the Thermoglaze, never use force to assemble, disassemble, operate, clean, or maintain it. Belshaw Bros., Inc. • 1750 22nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 MN-1716EN Thermoglaze 50 1 Unloading and Uncrating DO NOT LIFT EXCESSIVE WEIGHT Once the crate has been delivered, immediately take the covers off the crate and inspect for hidden damage. If damage is found, please see the above information to make a damage claim to the shipping company. After inspection, cut the banding and remove any other restrains from the Thermoglaze unit. Remove the banding and other packing material from the Thermolizer unit. Roll the Thermolizer, carefully, off the skid first and move it near the area where it will be assembled. Roll the Thermoglaze unit, carefully, off the skid and move it near the area where it will be assembled. Do not connect the Thermoglaze or the Thermolizer to electrical power before completing the assembly and placement of the products. Figure 1-1 shows the system in the crate ready to be unpacked. The cartons under the Thermoglaze contain the glaze trough and oven guard. See Section 4 to assemble the unit. The carton in the Thermolizer contains the doors and other interior parts. See Thermolizer manual for assembly instructions. The Thermoglaze system has been designed for quick assembly and installation. Within a few minutes of receiving the system, the installer can have the Thermoglaze ready to make donuts if the electrical connections are properly installed and inspected by the prevailing local authorities. Figure 1-1 Belshaw Bros., Inc. • 1750 22nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 Thermoglaze 50 MN-1716EN Identification 2 This information is key to identification for service or ordering parts on the ThermoGlaze. When servicing the equipment, please have the Model and serial number so the technician can order the correct parts for you. To identify which Thermoglaze system you have, please use the following model number key: THERMOGLAZE DESCRIPTION KEY Model No: -Doz/hr: - Glaze Pump: Opt. Items: - Voltage: - Freq: - Phase: - TG 50 G = Gear Pump V = End Cover -50 208 50 1 25 L = Lift Pump M = Mono -50 220/240 60 3 N = No Pump A = RF Oper. 400/230 3 w/N B = LB Oper. 415/240 Location: C = LF Oper. D = RB Oper. C = CE/Export T = LB Oper/SPL w/ D = Domestic/Nema (thermolizer cabinet) B = Export/Non-CE W = Domestic/Pin/Sleeve E = Aust/NZ Note: TG-50 is RF/LB Operate only, without Thermolizer - Screen 17” x 25” TG-25 includes built in Thermolizer for 12 .” x 17” Screen Part No. Description Key Drawings 22080 OBS USE 22113, TG-25 JR. TJ-2004, TJ-4000 w/120V 22081 OBS USE 22114, TG-25 JR. TJ-2006, TJ-40...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien