Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Desa, modell PD15EA

Hersteller: Desa
Dateigröße: 594.25 kb
Dateiname: ed810c21-19ff-40a6-80e8-37d7e9c2e887.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Umbrella must be supported by a table. 31. Do not use or install umbrella into product at temperatures below freezing. A damaged product could result in the risk of fire, electric shock and injury to persons. 32. Do not use this at any elevation above floor level. Do not place on a table. 33. Locate product so “ON” light can be easily seen 10 ft (3.05 m) around and 5 ft (1.52 m) above. 34. If a table cloth is used on the table above the product, secure it to prevent movement due to wind. 35. Do not use in temperatures above 75° F (28.9° C). Nuisance tripping of manual reset thermal protector can occur. 36. Take precautions to prevent spilling drinks on product. 37. If the product will not operate, see specific instructions in Troubleshooting, page 5. 38. Save these instructions for future reference. This product contains and/or generates chemicals known to the state of California to cause cancer or birth defects, or other reproductive harm. PRE-OPERATING INSTRUCTIONS GROUND FAULT INTERRUPTER • Since 1971 the National Electric Code (NEC) has required Ground Fault Circuit Interrupter devices on all outdoor circuits. • If your residence was built before 1971, check with a qualified electrician to determine if a Ground Fault Circuit Interrupter protector exists. • Do not use this product if the circuit does not have a GFCI protection. • Do not plug this product into an indoor circuit. • Typical accepted GFCI devices are shown in Figure 1. • Avoid the use of an extension cord. Extension cord may overheat and cause risk of fire. If you must have an extension cord, the cord shall be minimum size of 14 awg and not rated less than 1875 watts. Use only 3 wire cord type (3 prong plug) marked for outdoor use. RESETTESTWARNINGGFCI Cord Adapter Figure 1 - GFCI Options Test and Reset Buttons PLUG ADAPTER IMPORTANT: This product must be used on a grounded supply circuit. An adapter as shown in Figure 2 is available for connecting three-prong grounding type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. Grounded Outlet Box Figure 2 - Plug Adapter Metal Screw Cover of 113612-01B PRODUCT IDENTIFICATION Body Lighted On/Off SwitchPower Cord Thumb Screw Warm Air Exhaust Air Intake (opening to bottom of warmer) (Bottom Tip Switch Push Rod Access to Thermal Limit Switch Air Intakes View) Figure 3 - Umbrella Stand Warmer UNPACKING 1. Remove all packing items applied to product for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If product is damaged, promptly inform dealer where you bought product. INSTALLATION 1. Locate product under outdoor patio table on hard, level, dry surface. Post of tip over switch must be on solid surface for product to work. Listen for the “click”. See Figure 3 for switch location. 2. Slowly lower umbrella pole into product. Do not drop pole, it may damage product. 3. Tighten thumb screw of product to secure pole. Pole will be approximately 7 inches higher than if used without this product. 4. Make sure the product is in the OFF position before plugging into a grounded GFCI protected 120V 60 HZ outlet. 5. Avoid overloading your circuit by not using other high wattage products in the same outlet. At 1500 watts, this unit draw 12.5 Amps. OPERATION IMPORTANT: Review andunderstand the warnings in the Safety Information section, page 2. They are needed to safely operate this product. Follow all local ordinances and codes when using this product. 1. Push lighted ON/OFF switch. 2. The power light will remain lit during operation. 3. Stay back from product until all water or debris has blown clear. 4. Product will warm in a few minutes. 113612-01B CLEANING DURING SEASON CARE Always unplug the product before moving or cleaning. 1. Do not disassemble. Carefully wipe the exterior of unit with a soft, damp cloth. 2. After cleaning, be sure to completely dry the unit with a cloth or towel. AFTER SEASON CARE Store product indoors in a dry location. No maintenance is required for this product. TROUBLESHOOTING CAUTION: Risk of electric shock.Donotopen.Nouserservicable parts inside. Take heater to an authorized service center. If your product fails to operate: 1. Make sure the electrical outlet GFCI or circuit breaker and extension cord is working. 2. Check for operation of tip switch. The ON/ OFF switch light can be on but the tip switch OFF. Move product until a “click” is heard. To prevent damage of tip switch post, do not slide product. 3. Look for obstructions around fan. If you find an obstruction, turn the product OFF and UNPLUG THE PRODUCT. Have the product serviced by a qualified individual. 4. Check for tripped thermal protector. Motor and heating element do not operate. Wait 10 minutes for product to cool. Push reset button. See Thermal Limit Switch below. THERMAL LIMIT SWITCH If product is used in temperatures below 75° F (28.9° ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien