|
Anleitung Zusammenfassung
Installation Instructions) [ROM Version No.: 40] For the sake of brevity, we use the term "DSC-5 (R)“ to refer to both the DSC-5 (hanger type) and DSC-5R (rack mount type). f FURUNO ELECTRIC CO., LTD. I NISHINOMIYA, JAPAN ©FURUNO ELECTRIC CO., LTD. 9-52, Ash i hara-cho, N i sh i nom i ya, Japan 662 Telephone: 0798-65-2111 Telefax: 0798-65-4200 All rights reserved. ; Printed in Japan FIRST EDITION T APR 1991 OCT. 29, 1 997 (TATA) PUB. No. OME—55220 DSC—5/5R *00080215800* 00080215800 INSTRUCTIONS FOR CANCELLING A FALSE DISTRESS ALERT VHF DSC 1. Switch off transmitter immediately. 2. Switch equipment on and set to Channel 16. 3. Make broadcast to "All Stations" giving your vessel's name, callsign and DSC number, and cancel the false distress alert. Example message: All Stations, All Stations, All Stations This is NAME, CALLSIGN, DSC NUMBER, POSITION. Cancel my distress alert of DATE, TIME, UTC. =Master, NAME, CALLSIGN. DSC NUMBER, DATE, TIME UTC. (9610, PUB.N0.E59-60030-0 ) FM8500 DSC5/8V INSTRUCTIONS FOR CANCELLING A FALSE DISTRESS ALERT DSC MF 1. Switch off equipment immediately 2. Switch equipment on and tune for radiotelephony transmission on 2, 182 kHz 3. Make broadcast to "All Stations" giving the vessel's name, callsign and DSC number, and cancel the false distress alert. Example message: All Stations, All Stations, All Stations This is NAME, CALLSIGN, DSC NUMBER, POSITION. Cancel my distress alert of DATE, TIME, UTC. =Master, NAME, CALLSIGN. DSC NUMBER, DATE, TIME UTC. DSC HF Same as for MF but the alert must be cancelled on all the frequency bands on which it was transmitted. Hence, in stage 2.2 the transmitter should be tuned consecutively to the radiotelephony distress frequencies in the 4, 6, 8, 12 and 16 MHz bands, as necessary. (9610, PUB.N0.E59-60040-0 ) DSC-5/5A/6/6A A SAFETY INSTRUCTIONS "DANGER", "WARNING" and "CAUTION" notices appear throughout this manual. It is the responsibility of the operator and installer of the equipment to read, understand and follow these notices. If you have any questions regarding these safety instructions, please contact a FURUNO agent or dealer. A DANGER This notice indicates a potentially hazardous situation which, if not avoided, will result in death or serious injury. A WARNING This notice indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. This notice indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury, or property damage. i a SAFETY INFORMATION ¿h FOR THE OPERATOR ^WARNING Do not open the cover of the equipment. This equipment uses high voltage electricity which can shock, burn, or cause death. Only qualified personnel should work inside the equipment. Do not dissasemble or modify the equipment. Fire, electrical shock or serious injury can result. Immediately turn off the power at the ship's mains switchboard if water or foreign object falls into the equipment or the equipment is emitting smoke or fire. Continued use of the equipment can cause fire, electrical shock or serious injury. A CAUTION Do not place liquid-filled containers on the top of the equipment. Fire or electrical shock can result if a liquid spills into the equipment. Do not place heater near the equipment. Heat can melt the power cord, which can result in fire or electrical shock. Do not operate the unit with wet hands. Electrical shock can result. Use the correct fuse. Use of the wrong fuse can cause fire or equipment damage. WARNING Label attached A WARNING A To avoid electrical shock, do not remove cover. No user-serviceable parts inside. V__J Name: Warning Label (1) Type : 86-003-1011-0 Code No. : 100-236-230 ii yjv SAFETY INFORMATION ¿IS FOR THE INSTALLER ^WARNING Only qualified personnel should work inside the equipment. This equipment uses high voltage electricity which can shock, burn, or cause death. Turn off the power at the ship's mains switchboard before beginning the installation. Post a warning sign near the switchboard to ensure that the power will not be applied while the equipment is being installed. Serious injury or death can result if the power is not turned off, or is applied while the equipment is being installed. A CAUTION a Ground the equipment. Ungrounded equipment can give off or receive electromagnetic interference or cause electrical shock. Confirm that the power supply voltage is compatible with the voltage rating of the equipment. Connection to the wrong power supply can cause fire or equipment damage. The voltage rating appears on the label at the rear of the equipment. iii Table of Contents SPECIFICATIONS........................................ iii INTRODUCTION.......................................... 1 CHAPTER 1. OPERATION................................ 1-1 1. BASIC OPERATION......................................................1-3 2. DESCRIPTION OF FRONT P...
Dieses Handbuch ist für folgende Modelle:Boote Zubehör - DSC-5R (8.88 mb)