Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Diamond Power Products, modell DL 5000

Hersteller: Diamond Power Products
Dateigröße: 1.85 mb
Dateiname: DL5000_manual.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Be sure the power switch is in the OFF position before plugging in the band saw. • Always disconnect band saw from electrical outlet before setting up or servicing. • Wear proper apparel. Never wear loose fitting clothes, neckties, jewelry and gloves that may get caught in moving parts. • Remove all wrenches before using band saw. Leaving wrenches attached while operating this tool may result in damage to the machine and/or operator. • Always wear safety goggles. Everyday eyeglasses have only impact resistant lenses; they are not safety glasses. • Never turn on band saw while glass or working materials are touching the blade. • Always hold material being cut firmly on cutting table. • Feed materials at a slow easy pace into the blade. Avoid sudden twisting of the blade, which may cause kinking or breaking. • Keep out of reach of children. • Never leave saw running unattended. Turn power off when not in use. • Do not operate while under the influence of medication or alcohol. • To ensure top performance keep band saw properly maintained. Contents Your Diamond Laser 5000™ has been shipped partially assembled. Carefully remove saw and parts from the packaging. 1-Band Saw Body 2-Cutting Table 3-Recirculating water pump and valve 4-Detachable Water Reservoir 5-Straight Edge/Angle Cutting Guide 6-Adjusting Wrenches 7-Extra Diamond Laser Band Saw Blade Assembly Instructions A. Table Installation 1) Remove table mounting set screws and washers from the table mounting block directly behind the blade (Fig.1). Loosen and remove the table alignment screw and wingnut located on the front of the cutting table blade slot (Fig.2). 2) While holding the table with the slot opening directly behind the blade, carefully slide the diamond blade through the slot. 3) Secure cutting table to the mounting block with the table mounting set screws. Return alignment screw to the front of the cutting table and tighten in place with the wingnut positioned under table. 1. 7. 6. 5. 4. 3. 2. Fig.1 B. Blade Installation Blade comes pre-installed; however should it become loose in shipment or need to be replaced, follow these instructions. 1) Turn power OFF and unplug from electrical outlet. Open the band saw cover by loosening the knobs on the front of the saw and removing front panel. 2) Remove table alignment screw and wing nut. 3) Loosen blade tensioning knob, located at the top of the band saw (Fig.3) until blade has give. 4) Pull downward on the upper blade wheel (Fig.4) and remove worn blade. Install the new blade by centering it on the lower blade wheel (Fig.5), then on the center wheel and finally on the upper wheel. 5) Ensure blade is centered and fits between the blade guides located on the upper guide block and the lower block under the table. (refer to section D - Band Saw Use and Maintenance: Blade Guide Adjustment).6) Tighten blade by turning blade tensioning knob clockwise (Fig.3) (refer to section C - Band Saw Use and Maintenance: Blade Tensioning). 7) If necessary, adjust table position to re-center blade in the table opening. WARNING: If the diamond blade is too loose, it can slip from the wheels. If stretched too tight, it could break. C. Water Systems 1) Place the water reservoir on a solid level work surface. Place reservoir underneath the lip located on the right side of the saw base (Fig.6). 2) Insert brass pump valve into the top of the recirculating water pump. Place pump in the water reservoir (Fig.7). 3) Plug pump’s electrical connector into the outlet on the rear of the saw (Fig.8). 5) Fill the reservoir with 2” of water before use (approximately 3 quarts). 6) To test pump, the saw must be turned ON. Be sure the blade has been properly installed and there are no obstructions to interfere with its operation and blade movement. DO NOT attempt to touch the blade or blade wheels while the machine is turned ON. 7) Test pump and water flow by turning machine ON. The blade should not be moving; be sure reostat is turned to “0”. Watch for bubbles in the hose. Water should begin to flow freely from the water nozzle mounted on the upper blade guide block assembly. To insure water flow is directed at the front edge of the blade, just below the guide assembly, adjust position of water nozzle by loosening the set screw (Fig.9). 8) If large pockets of air appear in the hose line, this may stop the flow of water to the blade. If this occurs, prime the pump by tipping it on its side and allow the intake to draw in air through the line. Then return the intake grill into the water and watch for the water to fill the line. Small air bubbles may persist in the line but these will not interfere with sufficient flow to the blade. WARNING: Never operate saw if there is insufficient water at the point of cutting, as this will cause damage to the blade. Page 2 - DL5000 INSTRUCTION MANUAL Fig.2 Table Alignment Screw Fig.3 Fig.4 Fig.5 Fig.6 Fig.7 Fig.8 Band Saw Use and Maintenance A. Drive Belt Tension Adjustment A loose drive belt may re...

Dieses Handbuch ist für folgende Modelle:
Kreissägen - DL 5000 (1.85 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien