Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Carrier, modell WEATHERMAKERTM TWO-SPEED 38TDB

Hersteller: Carrier
Dateigröße: 190.99 kb
Dateiname: 38tdb-4si.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


11—Typical 24V Wiring Diagram (Cont) required. The LCC for standard PSC blower products consists of a standard humidistat which opens contacts on humidity rise and a pilot duty relay with 24v coil. NOTE: If an LCC is desired, low-speed airflow must be maintained so that a minimum of 300 CFM/ton can be supplied during high speed LCC operation. Step 9—Make Airflow Selections AIRFLOW SELECTION FOR 58CVA/58MVP FURNACES The 58CVA/58MVP Non-Condensing Variable Speed Furnaces provide high-and low-speed blower operation to match the capacities of the compressor at high and low speeds. To select the recommended airflow and for adjustments to the manual switches labeled SW1, A/C and CF on the control board refer to the furnace Installation, Start-Up, and Operating Instructions. The 315AAV utilizes a control center that allows the installing technician to select the proper airflows. The A/C switch determines the airflow during high speed compressor operation. Airflow for hight and low speed can be calculated at either 350 CFM per ton or 400 CFM per ton based on the positions of SW1-5. AIRFLOW SELECTION FOR FK4C, FV4A, OR 40FK FAN COILS The FK4C and FV4A provide high-and low-speed blower operation to match the capacities of compressor at high and low speeds. To select recommended airflow, refer to the FK4C, FV4A, or 40FK Installation Instructions. The FK4C, FV4A, and 40FK utilize an EASY SELECT control board that allows the installing technician to select proper airflows. For adjustments to control board and recommended A/C SIZE and CFM ADJUST selections. This fan coil has an adjustable blower off delay factory set at 90 sec for high-and low-speed blower operation. For other combinations of equipment consult the Product Data Digest. 8 LEGEND 24 VOLT FACTORY WIRING 24 VOLT FIELD WIRING FIELD SPLICE CONNECTION RELAY SPDT, PILOT DUTY 24-V COIL (HN61KK324) OR EQUIVALENT HUMIDISTAT, OPENS ON HUMIDITY RISE (HL38MG026) AIRFLOW SELECTOR R1 H AFS LEGEND 24 VOLT FACTORY WIRING 24 VOLT FIELD WIRING FIELD SPLICE CONNECTION RELAY SPDT, PILOT DUTY 24-V COIL (HN61KK324) OR EQUIVALENT HUMIDISTAT, OPENS ON HUMIDITY RISE (HL38MG026) AIRFLOW SELECTOR R1 H AFS A01222 WIRING DIAGRAM NOTES: 1. WIRING MUST CONFORM TO NEC OR LOCAL CODES. 2. UNDERLINED LETTER ON THERMOSTAT TERMINAL INDICATES USAGE. FOR EXAMPLE: O/W2 MEANS O IS ENERGIZED IN COOLING MODE. 3. REFER TO INDOOR UNIT INSTALLATION INSTRUCTIONS FOR ANY ADDITIONAL FEATURES AND WIRING INFORMATION. 4. NON-PROGRAMMABLE MODEL 2S01–B, WHEN USED IN AIR CONDITIONING INSTALLATION THE R19 JUMPER MUST BE CUT AND REMOVED. 5. PROGRAMMABLE MODEL 2S01–B MUST HAVE DIP SWITCH C ON WHEN USED IN AIR CONDITIONER APPLICATIONS. 6. THERMIDISTAT DIP SWITCH NO. 1 SHOULD BE SET IN OFF POSITION FOR AIR CONDITIONER APPLICATIONS (FACTORY DEFAULT). 7. AS AN OPTION O/W2CAN CONTROL SECOND-STAGE HEAT. 8. THERMIDISTAT DIP SWITCH NO. 2 SHOULD BE SET IN THE ON POSITION FOR DUAL CAPACITY COMPRESSOR OPERATION. 9. TO ACTIVATE DEHUMIDIFY FUNCTION ON FK4 OR FV4, REMOVE J1 JUMPER AT FAN COIL CONTROL BOARD. 10. AS AN OPTION, LOCK FURNACE INTO LOW-FIRE OPERATION AND LET O/W2 CONTROL HIGH FIRE OPERATION. REFER TO FURNACE INSTALLATION INSTRUCTIONS FOR PROPER SETUP. 11. TO ACTIVATE DEHUMIDIFY FEATURE ON CURRENT STYLE, VARIABLE-SPEED, 80 PERCENT NON-CONDENSING, FURNACE DISCONNECT GREEN (DEHUM) WIRE FROM G ON FURNACE CONTROL BOARD AND CONNECT TO DEHUMIDIFY TERMINAL DHUM ON THERMIDISTAT. 12. THE DE JUMPERS MUST BE REMOVED TO ENABLE THE DEHUMIDIFICATION FEATURE ON FURNACE. Table 2—Accessory Usage ACCESSORY REQUIRED FOR LONG-LINE APPLICATIONS* (50-175 FT.) REQUIRED FOR SEACOAST APPLICATIONS (WITHIN 2 MILES) Coastal Filter No Yes Support Feet No Recommended Puron® Balance-Port Hard Shut-off TXV Yes† Yes† * For tubing line sets between 50 and 175 ft horizontal or 20 ft vertical differential, refer to Application Guideline and Service Manual—Air Conditioners and Heat Pumps Using Puron® Refrigerant. Crankcase heater and start assist are standard on two-speed units. † Required for all applications. 9 Reversing Valve ConnectionLow/High SpeedContactorConnection Defrost Time Selectors Thermostat Low Voltage Reserved for Future Use CEBD430439-03A SS0ID PL1 PL2 HP/ACCSEVRVSCHILO PL3 PL4 PL5 OCT OAT HPS LPS PWM2 PWM1 BRN BLU BLK YEL RED CCH L2 ODF VH VC HK38EA001 K1 CEPL130439-01COMM ST A TUS D51 D52 A B C D 0 Y2 Y1 W1 C R 120 30 60 60 30 90 DEFROST TIME (MIN) R39 R44 R42 C18 C16 R36 FORCEDDEFROST 1 1 1 S1 R89 R91 R87R86 R85 J1 C31 R61 R65 R38 R33 C2 R9 1 2 Low Pressure Switch Connector High Pressure Switch Connector Thermistor Connection To Run Capacitor O.D.F. Connection Crankcase Heater Control Box Side of Unit THERMISTOR PLACED UNDERNEATH BASE PAN (ATTACHED TO BASE PAN WITH ADHESIVE) A00430 Fig. 14—View from Top of Base Pan To prevent personal injury wear safety glasses, protective clothing, and gloves when handling refrigerant and observe the following: • Back seating service valves are not equipped with Schrader valves. Fully back seat (coun...

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien