Step 4. Figure 2 STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD EMERGENCY 1 2 9 8 7 6 3 4 5 10 1 2 9 8 7 6 3 4 5 10 No. Symbol Function LED Display / Symbol Example 1 EMERGENCY Stops all the actions of the machine. Except when “HOT” shows on the LED display. “STOP” (flashing) 2 STAND BY / LED Temporarily lowers the temperature of glue tank so it won’t burn the glue when the machine is not operated. STBY00 3 CLOSE Closes clamp. 4 LED DISPLAY 1. The amount of books bound. 2. Operating status. 3. Perform self-test and stir the hot melt glue. 4. Error messages. ____100 BIND S-TEST ERR = L1 5 CLEAR Clears the display counter for books bound. ____0 6 COUNTER Displays the current total amount of binding. ____25 7 START / LED Indicates the “START” button is ready for proceeding to the next operation. 8 OPEN Opens clamp. 9 FUNCTION / LED Select one of the function modes – MANUAL, AUTO, or PAD. One of the mode indicators will be lit. 10 NOTCH / LED Select the notching function during the bookbinding operation. CONTROL PANEL STARTUP 1. Turn ON the power switch of PF-3200 as shown. The heater of PF-3200 will automatically heat the glue to the preset working temperature and display the status of the heating processes. • The 4 leftmost spaces of LED: the status of heating process (COLD, WARM, or HOT). • The 2 rightmost spaces of LED: the elapsed time of heating. 2. Start of Glue Melting Process. The status is COLD and the elapsed time is one minute for this example as shown. 3. Melting glue is processing. The status is WARM and the elapsed time is 10 minutes for this example as shown. 4. After heating for a while, the glue temperature has reached HOT status. The elapsed time is 20 minutes for this example as shown. 5. When the glue temperature has reached the working temperature, PF-3200 performs the self-test and stirs the melting glue. 6. PF-3200 is ready for bookbinding and set to MANUAL mode for your desired operation. At this moment, the control panel will display and flash “LOAD BOOK” for your attention. For binding operations, please refer to the MANUAL, AUTO and PAD operations. STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD COLD 01 2. STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD WARM 10 3. STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD HOT 20 4. STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD S-TEST 5. STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD LOAD 6. STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD BOOK Figure 4 Figure 3 After the “STARTUP” procedures, the PF-3200 will automatically set itself MANUAL operation and flashing “LOAD BOOK” display. Note that the “NOTCH” LED is ON. 1. A. Press the “OPEN” button and place the book block inside the clamps. Be sure to follow the label instructions on the clamp to load the book block to the RIGHT of the red line, then slide the book block to the far LEFT of the clamps and you will see the flashing “PUSH CLOSE” display. B. Then press the “CLOSE” button to clamp down the book block and you will see the flashing “PUSH START” display. Note: In case you need to adjust the book block after you have closed the clamps, you can press the “OPEN” button twice to release it. The LED display will show “PUSH CLOSE”. After you have adjusted the book block, you have to press and hold the “CLOSE” button until the clamps close. Then you will see the flashing “PUSH START” display again. C. Press the “START” button. The LED display of control panel will show a “¬ ” sign and the clamp station will move over the notching station for notching. 2. After the first notching process, the clamp station will remain to the left side of PF-3200 and the LED display of the control panel will display and flash “LOAD COVER”. 3. Center the cover sheet and adjust the side guide: Measure the width of the book plus half the thickness of the spine. Then set side guide accordingly. 4. Place the cover on the nipping station, the “START” LED will be lit and flashing “PUSH START”. Then press the “START” button to move the clamp station over the nipping station starting the binding process for the book block and cover sheet. MANUAL MODE STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD LOAD STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD BOOK STAND BY COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD PUSH STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD CLOSE STAND BY COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD PUSH STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD START STAND BY NOTCH FUNCTION READY MANUAL AUTO PAD LOAD STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUAL AUTO PAD COVER STAND BY CLEAR COUNTER START OPEN CLOSE NOTCH FUNCTION READY MANUA...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien