Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Fujitsu, modell HALCYON AOU18CL

Hersteller: Fujitsu
Dateigröße: 904.14 kb
Dateiname: (OM)ASU18CL.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period. POLYPHENOL CATECHIN AIR CLEANING FILTER The polyphenol catechin air cleaning filter uses static electricity to clean the air of fine particles and dust such as tobacco smoke and plant pollen that are too small to see. The filter contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria SLEEP TIMER When the SLEEP button is pressed during cooling mode, adsorbed by the filter. the thermostat setting is gradually raised during the period Note that when the air cleaning filter is installed, the amount of operation. When the set time is reached, the unit auto- of air produced decreases, causing a slight decrease in the matically turns off. air conditioner's performance. WIRELESS REMOTE CONTROL UNIT NEGATIVE AIR IONS DEODORIZING FILTER The Wireless Remote Control Unit allows convenient con- It comprises pottery super micro particles, which can pro trol of air conditioner operation. duce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home. The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room. SWING OPERATION WIRED REMOTE CONTROL UNIT (OPTION) The optional wired remote control unit (model No.: UTB-UUB) can be used. When you use remote control unit, there are following different points as compared with using wireless remote control unit. [The additional functions for wired ones] • Weekly timer • Temperature set back timer [The restricted functions for wired ones] • QUIET can't be selected in FAN MODE. • Sleep-timer can't be used. And you can't use both wired remote control unit and wireless simultaneously. (Only one kind can be selected) En-2 05M150_9315255020-01_En 2 2005.12.15, 10:56 NAME OF PARTS Fig. 1 Indoor Unit 1Operating Control Panel (Fig. 2) 2MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start. The forced cooling operation is used at the time of installation. Only for authorized service personnel's use. When the forced cooling operation starts by any chance, press the START/STOP but- ton to stop the operation. 3Indicator (Fig. 3) 4Remote Control Signal Receiver 5OPERATION Indicator Lamp (red) 6TIMER Indicator Lamp (green) If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 14 Auto Restart). 7SUPER QUIET Indicator Lamp (green) 8SWING Indicator Lamp (orange) 9Intake Grille (Fig. 4) 0Front Panel AAir Filter BAir Flow Direction Louver CRight-Left Louver (behind Air Flow Direction Louver) DDrain Hose EAir Cleaning Filter Fig. 5 Outdoor Unit FPipe Unit GDrain port (bottom) HIntake Port IOutlet Port Fig. 6 Remote Control Unit JSLEEP button KMASTER CONTROL button LSET TEMP. button ( / ) MSignal Transmitter NTIMER MODE button OTIMER SET ( / ) button PFAN CONTROL button QSTART/STOP button RSET button SSWING button TRESET button UTEST RUN button This button is used when installing the conditioner, and should not be used un- der normal conditions, as it will cause the air conditioner’s thermostat function to op- erate incorrectly. If this button is pressed during normal op- eration, the unit will switch to test opera- tion mode, and the Indoor Unit’s OPERA- TION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously. To stop the test operation mode, press the START/STOP button to stop the air condi- tioner. VCLOCK ADJUST button WRemote Control Unit Display (Fig. 7) XTransmit Indicator YClock Display ZOperating Mode Display [Timer Mode Display \Fan Speed Display ]Temperature SET Display `SLEEP Display aSWING Display Refer to the folded out page on the cover. En-3 05M150_9315255020-01_En 3 2005.12.15, 10:56 PREPARATION CAUTION! Take care to prevent infants from accidentally swallowing batteries. When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit. If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi- ately wash with copious amounts of water, and consult your physician. Dead batteries should be removed immediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority. Do not attempt to recharge dry batteries. Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the Remote Con- trol Unit’s operating range becomes ap- preciably reduced, replace the batteries and press the RESET button with the tip of a ballpoint pen or other small object. Insert Press in Turn on the Power 1 In the case of a direct line connec...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - HALCYON AOU18CL (904.14 kb)
Splitgeräte - HALCYON ASU18CL (904.14 kb)
Splitgeräte - HALCYON ASU18CL (904.14 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien