|
Anleitung Zusammenfassung
Fasten (double nuts) (3)Proceed with procedure (4) of " In the case of no ceiling " Insert Washer fixing pad (prepared in feild) leveler Polythene pipe [ secure the washer firmly] 13 Installation Procedures 4. Installation of water drainage pipe (1) Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm ) Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slope of drainpipe cannot be made,lifting pipe shall be installed. Keep a distance of 1-1.5m between suspending bolts, to make water hose straight. slope over 1/100 1-1.5m Use the drainage hose and clip provided with unit. Insert water pipe into water plug until it reaches the white tape. Tighten the clip until head of the screw is less than 4mm from hose. Wind the ddrainage hose to the clip using seal pad for heat insulation. Insulate drainage hose in the room. Large size seal pad Clip Tape(white) Draingage hose Less than 4mm (accessory) Clip 5. Cautions for the water drainage lifting pipe Installation height of water drainage lifting pipe shall be less than 280mm There should be a right angle with unit ,300mm from unit. < Note > Clip Water drainagelifting pipe Suspending bracket Drainage hose Less than 280mm Less than 500mm220mm Less than 300mm 1-1.5m 220 Drainage hose Less than 75mmLess than 500mm The slope of water drainage hose shall be within 75mm , make the drainage plug not to bear excessive force. If several water hoses join together, of as per following procedures. 100mm .over Slope less than 1/100 Connection drainage hose with a T-joint Specifications of the selected drainage hoses shall meet the requirements for the unit running 14 15 6. Installation of Ornament Panel Install ornament panel on indoor unit (1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel. (2) Fasten the screws to make the height difference between the two sides of indoor unit less than 5mm. (3) First fix it with screws temporally. (4) Fasten the two temporally fixing screws and other two, and tighten the four screws. (5) Connect the wires of swing-motor. (6) Connect the wire of signal. (7) If no response of remote controller,check whether the wiring is correct,restart remote controller 10 seconds after shut off power supply. Limits of panel board installation (1)Install the panel board in the direction shown in the figure. (2)The incorrect direction will result in water leakage, meanwhile swing and signal receiving are displayed that cannot be connected. Control box Installation Procedures Installation Procedures 7. Piping Connection Flare connection 3-way valve Gas pipe AB092XCERA AB122XCERA Liquid Indoor Unit OutdoorunitFlare connectionpipe 2-way valve Flare connection 3-way valve Indoor Unit Gas pipeAB142XCERA AB182XCERA A(adaptor, from 9.52 to 12.7) Outdoor unit Liquid pipe 2-way valveFlare connection A To gas pipe To outdoor unit (1) Dimension of connecting pipe AB092XCERA AB122XCERA Gas pipe 9.52mm Liquid pipe 6.35mm AB142XCERA AB182XCERA Gas pipe 12.7mm Liquid pipe 6.35mm 90 0.5O (2) The maximum length and drop height of connecting pipe The maximum length is 20m Fit the nut on and fasten Joint To ensure the efficiency , Pipes shall be as short as possible. Spanner Cautions for piping connection The maximum drop height is 10m. Do not twist or deform the connecting pipe. Do not mix dusts. The bending radius shall be as large as possible. Both gas pipe and liquid pipe shall be heat insulation. No leakage in the flare. (3) Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare. The bending radius shall be as large as possible. Align the pipe center when fastening, and tighten the nut, as shown in the figure. Pay attention to not mix foreign matters such as sands in. Spanner Nut If not aligned ,tighten the nut by force will damage the nut that result in gas leakage Diameter of Pipe Liquid Pipe 6.35mm Gas Pipe 12.7mm Tighten Torque (N. m) 11.8 49.0 Gas Pipe 9.52mm 40 16 Installation Procedures 8.Electrical Wiring Wiring methods: 1 Wiring method of ring terminal For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and tighten screw. L N T B Brazed seam B=8.0-9.0(mm) d d=4.3-5.3(mm) T=1.0-2.0(mm) Ring Terminal Wiring method of ring terminal (For your referrence) 2 Wiring of indoor unit The distance between the signal wires and the power cabes should be at least 50mm. CBAQP1(L) 2(N) 2(N) 1(L) P Q A B C L N C1 C2 (In case of using wired controller) To other indoor unit To wired controller To outdoor unit 1.Incorrect address setting will cause abnormal to the system. 2.Communication cable must be us...
Dieses Handbuch ist für folgende Modelle:Splitgeräte - AB142XCERA (895.9 kb)
Splitgeräte - AB182XCERA (895.9 kb)
Splitgeräte - AB122XCERA (895.9 kb)