Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Fedders, modell A6V05S2B

Hersteller: Fedders
Dateigröße: 455.54 kb
Dateiname: 6fcaed82-418d-16a4-7d0e-8d3740b1e96e.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3 WINDOW INSTALLATON INSTALLATION 9. Cut two pieces of adhesive back foam seal to height of window opening. Remove backing and apply to window frame and sliding sash that will rest against unit (Fig. 5). 10. Slide unit onto support platform. Be sure unit side channel butts against vertical edge of window frame. Note: If unit side channel does not fit securely, remove unit and readjust leveling bolt. 11. Drill two 1/8” holes through window channel frame in alignment with existing holes in bottom bar. Install two (2) 3/8” long self-tapping screws through these holes. If window channel frame is not tall enough to use existing holes, drill (2) new holes off to the side of the existing holes to attach the unit bottom bar to the support platform. Unit should be firmly anchored to window channel frame or support platform (Fig. 6). 12. Slide inside window sash closed. Be sure vertical edge of inside window sash is pressed firmly against side of unit cabinet. Cut remaining adhesive back foam seal to width of window opening. Remove backing and apply to top inside edge of window frame (Fig. 5). 13. Install speed clips on top and bottom inside edge of window to provide locking (Fig. 7). 14. Using supplied plastic foam seal, cut to proper length, insert between inside window sash and outside window (Fig. 7). 15. Place top retainer on top edge of filler panel, (Fig. 5) then place the bottom edge of filler panel into groove of bottom retainer (mounted on unit). Filler panel may be trimmed with knife or scissors to fit window height. 16. Slide sliders upward making sure filler panel aligns in sliders (Fig. 5). 17. With sliders up against top retainer, drill 1/8” hole through window frame in alignment with existing hole in slider. Install 3/8” long self-threading screw in hole. Repeat for other slider (Fig. 6 & 7). 18. Check all seals and plug all air leaks around unit. Use sealant to fill any minor openings. Fig. 5 B A C D A E Foam SealA D Sliders Top Retainer B E Side Channel Filler PanelC Do not obstruct the air intake area of your air conditioner, as this could cause overheating, thus activating the units security switch and shutting off the unit. Do not block aiflow inside with blinds, curtains, or furniture. Do not block airflow outside with shrubs, enclosures, or other buildings. A Fig. 6 B C D Widow Channel Frame Drilled Holes Bottom Bar A C B 3/8” long self tapping screwsD Do not drill a hole in the bottom pan. Unit is designed to operate with approximately 1/2” of water in bottom pan. 4 WINDOW INSTALLATON INSTALLATION Casement Window Installation This air conditioner is designed to fit into most casement type windows. As shipped from factory, unit will fit into a minimum window opening 15 1/2” wide and 21” high. The preferred method of installation is through a closed or stationary window. Installation in an open window frame is also possible where open window can be secured to outside of building or removed completely. 1. Closed or Stationary Window: Install unit in stationary sash to avoid crank handles or window latches. If unit is to be installed in or next to a movable sash, it may be necessary to remove catch, handle or both. Remove crank handle and secure window in closed position. Remove glass panes and separating strips to a height sufficient to mount unit. 2. Open Window Frame: Remove crank mechanism and catch handles. Fold window sash back against exterior wall of building and secure, or remove completely where possible. 3. A filler panel will be required at side of unit when installed in windows having width greater than 15 1/2”. Filler panel should be made from 3/4” thick wood securely anchored to one side of opening so that 15 1/2” wide opening is provided. Filler panel should run full length of window. Paint to suit. 4. Install unit in same manner as described for sliding windows. Installation in Wood Sliding or Wood Casement Windows 1. For wood frame casement windows, it is necessary to construct a frame, using at least 1” thick wood with a 15 1/2” wide opening. 2. Paint frame and fasten it securely, sealing it into window opening. Fig. 7 A B C D E D E Foam SealA D Drilled holes ChannelB E 3/8” long screw Speed ClipC 3. Install unit into frame following procedures for metal sliding and casement windows. These installations are also typical, and since styles and sizes of casement windows vary widely, it is advisable to have unit installed by someone skilled in this type of installation. The dealer selling these units can recommend or supply qualified people to install your new unit. A C D E B Fig.8 Fig.8 Directing Airflow Air conditioner is engineered with adjustable louvers to direct discharge airflow. Louvers are manually adjusted by moving levers in direction of desired airflow. Fig.8 Cleaning Air Filter When air conditioner is operating, indoor air is filtered and refiltered continuously trapping airborne dirt and dust in the washable filter. Therefore, the filter should be inspected and cleaned...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien