Anleitung Zusammenfassung


Follow these steps to reset the Arc Detection Device: 1. Unplug unit from electrical outlet 2. Press the reset button 3. Plug the unit back into electrical outlet 4. Check to see if power has returned to the unit Testing You should test the Arc Detection Device equipped power cord monthly, after every major electrical storm, or if power to your Room Air Conditioner has been interrupted. Follow these steps to test the Arc Detection Device: 1. Unplug unit from electrical outlet 2. Press the reset button 3. Plug the unit back into electrical outlet 4. Press test button. Unit should trip and reset button will pop up. 5. Press reset button again for use If above test fails, stop using the air conditioner and contact customer service by calling the following toll- free number: 1-800-332-6658 or email: customerservice@fedders.com WARNING Do not operate this air conditioner without proper time delay circuit protection (circuit breaker or fuse). Refer to serial plate for proper power supply requirements. Recommended Wire Sizes (As installed per building code) : PROTECTOR SIZEWIRE GAUGE 15 AMP #14 MINIMUM 20 AMP #12 MINIMUM 250V 125V 250V 250V 30 AMP #10 MINIMUM 15A 15A 20A 30A WARNING Electrical Shock Hazard • Plug unit only into a grounded electrical outlet. • Do not use an extension cord or plug adapter with this unit. • Do not operate unit with decorative front or filter removed. • Failure to follow these precautions could result in electrical shock, fire or personal injury. • If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps, it must have its own fuse or circuit breaker, and no other device or unit should be operated on that fuse or circuit breaker. • If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on that fuse or circuit breaker. • We recommend that a qualified electrician install unit in accordance with the National Electrical Code and local codes and ordinances. • Use copper conductors of correct wire gauge and protector size only. • Do not alter cord or plug end. Do not remove warning label on cord. Important Grounding Requirements • Air conditioner has a three-prong grounding plug on the power supply cord, which must be plugged into a properly grounded three-prong wall receptacle for your protection against possible shock hazard. For models up to and including 7.5 amperes, use a grounding type wall receptacle to match the cord plug. • For models above 7.5 amperes use a single outlet grounding type wall receptacle to match the cord plug. 1 Room Air Conditioner Room Air Conditioner Additional Safety Precautions Filler Panel Installation • Do not cut, alter or remove any of the expanded polystyrene (styrofoam) inside this air conditioner. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard or explosion. • Do not introduce objects in the air discharge area. This could cause permanent damage. • Do not pour liquids on the air conditioner as this could cause a malfunction. With the unit unplugged, use a damp cloth for cleaning the unit. • Do not use strong solvents to clean the air conditioner. • Clean the air conditioner filter every two weeks to avoid overheating caused by air obstruction. Do not operate without filter. • Do not obstruct the air intake area of your air conditioner, as this could cause overheating, thus activating the unit’s security switch and shutting off the unit. • Do not block air circulation to outside louvers of cabinet. • Do not block air flow inside with blinds, curtains, or furniture, or outside with shrubs, enclosures, or other buildings. • Do not run the air conditioner with an outside protective cover in place. This could result in fire or mechanical damage within the air conditioner. Window Requirements Air conditioner is factory prepared for installation in standard double hung windows (air conditioner cannot be installed in other types of windows). The air conditioner can be installed in windows 23” to 34” wide when filler panels are used. In windows 19” to 22” wide the air conditioner can be installed without the filler panels. All windows must open at least 12 3/4” vertically. Install the air conditioner in a window where there will be enough clearance around the cabinet to allow ample circulation of air through unit. All supporting parts should be secured to firm wood, masonry, or metal. Tools Needed Screwdrivers Tape Measure Carpenter’s Level 5/8” wood screws..............9 Brackets ............................2 A B A B Installation Parts Kit 1. Place tabbed side of curtain in track on side of air conditioner cabinet, and slide down the track until the curtain is even top and bottom (Fig.1). 2. Slide the filler panel frame onto the air conditioner cabinet using the tracks on the top and bottom of the unit. Slide the frame as close to t...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien