Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung York, modell AFFINITY 292443-XTG-B-0807

Hersteller: York
Dateigröße: 557.1 kb
Dateiname: 848de277-be65-49f4-b65e-0e23cb1b5d6c.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


MBH 20.0 17.7 16.8 16.8 20.6 18.2 17.3 17.3 21.2 18.7 17.8 17.8 21.4 19.0 18.0 18.0 21.7 19.2 18.2 18.2 TOTAL POWER INPUT kW 2.69 2.64 2.60 2.58 2.75 2.70 2.66 2.63 2.80 2.75 2.71 2.68 2.89 2.83 2.79 2.76 2.97 2.92 2.87 2.84 Sensible CapacityMBH1Entering DryBulb ° F 86 11.1 14.4 16.0 15.6 12.2 15.8 16.9 16.7 13.2 17.2 17.8 17.8 13.9 18.1 18.0 18.0 14.6 19.0 18.2 18.2 83 10.5 13.9 15.5 15.1 11.6 15.3 16.6 16.4 12.6 16.6 17.8 17.8 13.2 17.5 18.0 18.0 13.9 18.3 18.2 18.2 80 10.0 13.4 14.9 14.5 11.0 14.7 16.4 15.9 11.9 16.0 17.8 17.4 12.5 16.8 18.0 17.8 13.2 17.6 18.2 18.2 77 9.5 12.8 14.4 14.0 10.4 14.1 15.8 15.4 11.3 15.3 17.2 16.7 11.9 16.1 17.3 17.1 12.4 16.8 17.5 17.5 74 8.9 12.3 13.9 13.5 9.8 13.5 15.2 14.8 10.7 14.7 16.5 16.1 11.2 15.4 16.7 16.4 11.7 16.1 16.8 16.7 71 -11.8 13.3 12.9 -12.9 14.6 14.2 -14.0 15.9 15.4 -14.7 16.0 15.7 -15.4 16.0 16.0 68 -11.2 12.8 12.4 -12.3 14.0 13.6 -13.4 15.3 14.8 -14.0 15.3 15.0 -14.6 15.3 15.3 125 °F NET CAP. MBH 18.2 15.8 15.1 15.0 18.9 16.3 15.6 15.5 19.5 16.9 16.2 16.0 19.6 17.0 16.3 16.2 19.8 17.1 16.4 16.3 TOTAL POWER INPUT kW 2.83 2.77 2.74 2.70 2.89 2.83 2.80 2.76 2.95 2.89 2.86 2.82 3.03 2.97 2.94 2.89 3.11 3.05 3.01 2.97 Sensible CapacityMBH1Entering DryBulb °F 86 9.1 12.5 13.9 13.2 10.2 13.9 15.0 14.6 11.2 15.3 16.2 16.0 12.5 16.8 16.3 16.2 13.8 18.3 16.4 16.3 83 9.2 12.6 13.2 12.6 10.3 14.0 14.7 14.3 11.3 15.4 16.2 16.0 12.2 16.5 16.3 16.2 13.1 17.6 16.4 16.3 80 9.3 12.7 13.3 12.7 10.4 14.1 14.8 14.2 11.4 15.5 16.2 15.6 11.9 16.2 16.3 15.9 12.4 16.9 16.4 16.3 77 9.4 12.8 13.4 12.8 10.5 14.2 14.9 14.3 11.5 15.6 16.2 15.7 11.6 15.9 16.1 15.6 11.7 16.2 15.7 15.6 74 9.5 12.9 13.5 12.9 10.6 14.3 15.0 14.4 11.6 15.7 16.2 15.8 11.3 15.6 15.8 15.3 11.0 15.5 15.0 14.9 71 -13.0 13.6 13.0 -14.4 15.1 14.5 -15.8 16.2 15.9 -15.3 15.5 15.0 -14.7 14.3 14.1 68 -13.0 13.7 13.1 -14.5 15.2 14.6 -15.9 16.2 16.0 -15.0 15.2 14.7 -14.0 13.6 13.4 ALL SENSIBLE CAPACITY 1. These capacities are net capacities (the indoor fan heat is deducted). Unitary Products Group 292443-XTG-B-0807 Unitary Products Group 9 TABLE 5: DNA030 COOLING CAPACITIES - 2-1/2 TON TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 750 CFM 875 CFM 1,000 CFM 1,125 CFM 1,250 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 85 °F NET CAP. MBH 28.1 26.4 24.2 22.6 30.6 28.7 26.3 24.5 32.9 31.0 28.3 26.4 33.2 31.2 28.6 26.7 33.5 31.5 28.8 26.9 TOTAL POWER INPUT kW 2.99 2.95 2.90 2.89 3.03 2.99 2.94 2.93 3.06 3.02 2.97 2.96 3.13 3.09 3.04 3.03 3.20 3.16 3.11 3.10 Sensible Capacity MBH1 Entering Dry Bulb °F 86 15.3 19.8 23.6 22.6 18.6 23.6 26.0 24.5 21.9 27.4 28.3 26.4 21.1 26.8 28.6 26.7 20.2 26.2 28.8 26.9 83 14.5 19.0 22.8 21.9 17.0 21.9 25.6 24.2 19.4 24.9 28.3 26.4 19.3 25.1 28.6 26.7 19.3 25.2 28.8 26.9 80 13.7 18.2 22.1 21.2 15.3 20.3 24.6 23.6 16.9 22.4 27.2 26.1 17.6 23.3 28.0 26.5 18.3 24.2 28.8 26.9 77 13.0 17.4 21.3 20.4 13.7 18.7 23.0 22.0 14.5 20.0 24.7 23.6 15.9 21.6 26.3 24.8 17.3 23.3 27.8 25.9 74 12.2 16.7 20.5 19.6 12.1 17.1 21.4 20.4 12.0 17.5 22.2 21.1 14.2 19.9 24.6 23.0 16.4 22.3 26.9 24.9 71 - 15.9 19.7 18.8 - 15.5 19.8 18.7 - 15.0 19.8 18.7 - 18.2 22.8 21.3 - 21.3 25.9 24.0 68 - 15.1 19.0 18.1 - 13.8 18.1 17.1 - 12.6 17.3 16.2 - 16.5 21.1 19.6 - 20.4 24.9 23.0 95 °F NET CAP. MBH 26.8 25.0 22.3 21.4 29.2 27.3 24.3 23.4 31.7 29.6 26.4 25.4 32.0 29.9 26.6 25.6 32.2 30.1 26.8 25.8 TOTAL POWER INPUT kW 3.18 3.14 3.08 3.07 3.22 3.18 3.11 3.11 3.26 3.22 3.15 3.15 3.34 3.30 3.23 3.22 3.42 3.38 3.30 3.30 Sensible Capacity MBH1 Entering Dry Bulb °F 86 17.9 22.3 22.3 21.4 19.9 24.9 24.3 23.4 22.0 27.5 26.4 25.4 21.0 26.7 26.6 25.6 19.9 25.9 26.8 25.8 83 15.6 20.1 22.3 21.4 17.5 22.5 24.3 23.4 19.3 24.9 26.4 25.4 19.1 24.9 26.6 25.6 19.0 24.9 26.8 25.8 80 13.4 17.8 21.0 20.0 15.0 20.0 23.6 22.4 16.6 22.2 26.1 24.8 17.3 23.1 16.5 25.3 18.0 24.0 26.8 25.8 77 11.1 15.6 18.8 17.7 12.6 17.5 21.1 19.9 14.0 19.5 23.5 22.2 15.5 21.2 24.6 23.5 17.0 23.0 25.8 24.8 74 8.9 13.4 16.5 15.5 10.1 15.1 18.7 17.5 11.3 16.8 20.8 19.5 13.7 19.4 22.8 21.7 16.0 22.0 24.9 23.9 71 - 11.1 14.3 13.3 - 12.6 16.2 15.0 - 14.1 18.1 16.8 - 17.6 21.0 19.8 - 21.0 23.9 22.9 68 - 8.9 12.1 11.0 - 10.2 13.7 12.6 - 11.5 15.4 14.1 - 15.8 19.2 18.0 - 20.1 22.9 21.9 105 °F NET CAP. MBH 25.4 23.0 20.6 20.1 27.7 25.0 22.5 21.9 30.0 27.1 24.4 23.8 30.4 27.4 24.7 24.0 30.7 27.8 25.0 24.3 TOTAL POWER INPUT kW 2.94 3.31 3.23 3.24 2.98 3.36 3.28 3.29 3.03 3.41 3.33 3.34 3.10 3.49 3.41 3.42 3.17 3.57 3.48 3.49 Sensible Capacity MBH1 Entering Dry Bulb °F 86 15.9 20.0 20.6 20.1 17.7 22.3 22.5 21.9 19.6 24.7 24.4 23.8 19.5 24.9 24.7 24.0 19.5 25.1 25.0 24.3 83 14.4 18.5 20.5 19.9 16.1 20.7 22.5 21.8 17.8 22.9 24.4 23.8 18.2 23.5 24.7 24.0 18.6 24.1 25.0 24.3 80 13.0 17.1 19.6 18.8 14.5 19.1 21.9 21.0 16.1 21.2 24.3 23.3 16.9 22.2 24.6 23.8 17.6 23.2 25.0 24.3 77 11.5 15.6 18.1 17.3 12.9 17.5 20.3 19.5 14.4 19.5 22.5 21.6 15.5 20.9 23.3 22.5 16.7 22.2 24.0 23.4 74 10.1 14.2 16.6 15.9 11.3 15.9 18.7 17.9 12.6...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien