Anleitung York, modell 36

Hersteller: York
Dateigröße: 2.09 mb
Dateiname: a1018208-1c59-49bd-b1fa-b9822b1fe488.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor. NOMINAL RATING Unitary Products Group 255040-YTG-A-0506 TABLE 7: D(CE, CG)072 COOLING CAPACITIES (6 TON) AIR ON EVAPORATOR COIL TEMPERATURE OF AIR ON CONDENSER COIL 85°F 95°F TOTAL CAP.1 MBH POWER INPUT2 kW SENSIBLE CAPACITY1 TOTAL CAP.1 MBH POWER INPUT2 kW SENSIBLE CAPACITY1 ENTERING DRY BULB, °F ENTERING DRY BULB, °F CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 2700 72 80 5.7 63 55 47 40 32 --77 6.3 63 55 47 40 32 -- 67 80 5.7 76 68 60 53 45 37 30 77 6.3 75 68 60 53 45 37 30 62 70 5.5 70 70 70 62 55 47 39 71 6.3 71 71 71 63 56 48 40 57 68 5.6 68 68 68 60 52 45 37 71 6.3 71 71 71 63 56 48 40 2550 72 82 5.7 60 53 46 38 31 --76 6.3 60 53 46 39 31 -- 67 82 5.7 73 65 58 51 43 36 29 76 6.3 73 66 58 51 44 36 29 62 71 5.5 71 71 70 62 55 48 41 70 6.3 70 70 69 62 55 48 40 57 69 5.6 69 69 69 62 55 47 40 70 6.3 70 70 70 62 55 48 40 72 83 5.7 58 51 44 37 30 --75 6.3 58 51 44 37 30 -- 2400 67 83 5.7 70 63 56 49 42 35 28 75 6.3 70 64 57 50 43 36 29 62 73 5.5 73 73 70 63 56 49 42 69 6.3 69 69 68 61 54 47 40 57 71 5.6 71 71 71 64 57 50 43 69 6.3 69 69 68 61 54 47 40 2100 72 79 5.7 54 48 41 35 29 --73 6.3 53 47 41 35 29 -- 67 79 5.7 65 59 53 47 40 34 28 73 6.3 65 59 52 46 40 34 28 62 69 5.5 69 69 66 60 54 47 41 67 6.3 67 66 63 57 51 45 38 57 67 5.6 67 67 67 61 54 48 42 67 6.3 67 66 63 57 51 45 39 1800 72 74 5.6 50 44 39 34 28 --71 6.3 49 43 38 33 27 -- 67 74 5.6 60 55 50 44 39 34 28 71 6.3 59 54 48 43 38 32 27 62 65 5.4 65 65 62 57 51 46 41 65 6.2 65 63 58 53 47 42 37 57 63 5.5 63 63 63 58 52 47 42 65 6.3 65 63 58 53 47 42 37 CFM WB °F AIR ON EVAPORATOR COIL TEMPERATURE OF AIR ON CONDENSER COIL 105°F 115°F TOTAL CAP.1 MBH POWER INPUT2 kW SENSIBLE CAPACITY1 TOTAL CAP.1 MBH POWER INPUT2 kW ENTERING DRY BULB, °F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 67 62 57 2700 76 7.1 61 53 45 38 30 --75 7.9 59 51 43 36 28 -- 71 7.1 70 66 58 50 43 35 27 65 7.8 65 64 56 48 41 33 25 64 7.0 64 64 64 56 49 41 34 57 7.8 57 57 57 50 42 34 27 64 7.0 64 64 64 56 49 41 34 57 7.7 57 57 57 50 42 34 27 72 67 62 57 2550 76 7.1 59 51 44 37 29 --76 7.9 57 49 42 35 27 -- 71 7.1 69 64 56 49 42 34 27 66 7.9 66 61 54 47 40 32 25 64 7.0 64 64 64 56 49 42 35 58 7.8 58 58 58 51 43 36 29 64 7.0 64 64 64 56 49 42 34 58 7.7 58 58 58 50 43 36 29 72 67 62 57 2400 75 7.1 56 49 43 36 29 --76 8.0 55 48 41 34 27 -- 70 7.1 68 61 54 48 41 34 27 66 7.9 66 59 52 45 38 32 25 64 7.0 64 64 63 56 49 42 35 59 7.8 59 59 59 52 45 38 31 64 7.0 64 64 63 56 49 42 35 59 7.7 59 59 58 51 44 37 30 72 67 62 57 2100 73 7.1 52 45 39 33 27 --73 7.9 50 44 37 31 25 -- 68 7.1 63 56 50 44 38 32 26 63 7.8 61 54 48 42 36 30 24 61 7.0 61 61 58 52 46 40 34 56 7.7 56 56 54 48 42 35 29 61 7.0 61 61 58 52 46 40 34 56 7.7 56 56 53 47 41 35 29 72 67 62 57 1800 70 7.1 47 41 36 31 25 --69 7.8 45 40 34 29 23 -- 65 7.0 57 51 46 41 35 30 25 60 7.8 55 49 44 39 33 28 23 59 7.0 59 58 54 48 43 38 32 53 7.7 53 53 49 44 39 33 28 59 6.9 59 58 53 48 43 37 32 53 7.6 53 53 49 44 38 33 27 1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor. NOMINAL RATING Unitary Products Group 255040-YTG-A-0506 TABLE 8: SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE-IWG3 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 31,2 1700 835 705 880 745 923 795 969 860 1013 970 ---- 1600 811 655 854 695 898 740 942 790 986 840 1029 900 -- 1500 782 610 827 650 871 685 917 730 960 775 1003 825 1046 905 1400 --798 595 844 640 889 680 932 720 975 765 1018 790 1300 ----816 590 862 635 907 675 951 715 995 750 1200 ------834 585 881 630 927 665 970 705 1100 ------809 550 855 590 900 625 942 665 1000 ------782 510 829 545 872 858 919 625 900 --------797 500 843 540 890 580 UNIT TONNAGE AIR FLOW CFM AVAILABLE EXTERNAL STATIC PRESSURE-IWG3 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 3 1, 2 1700 -------------- 1600 -------------- 1500 -------------- 1400 1055 875 ------------ 1300 1036 780 1066 850 ---------- 1200 1011 735 1047 765 1075 800 -------- 1100 987 690 1028 720 1060 750 1084 775 ------ 1000 963 655 1005 680 1040 695 1068 715 1089 735 ---- 900 936 615 980 645 1020 660 1050 670 1053 68...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 48 (2.09 mb)
Splitgeräte - 60 (2.09 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien