Anleitung Bryant, modell 559D

Hersteller: Bryant
Dateigröße: 652.53 kb
Dateiname: pds559d.120.2b.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The air ducts connect to the curb only, therefore, the curb and ductwork may be installed before the unit arrives at the jobsite A 24-inch high, factory-supplied curb for side supply/return duct connections to an over-and-under duct configuration is also available for grade level or rooftop installation SYSTEM FEATURES FULL PERIMETER CURB MOUNTING ON PREFABRICATED ROOF CURB. The curb, which is easily field-assembled, can be installed at the jobsite before the unit is installed This eliminates a major leak source. An optional side supply/return roof curb for grade level installation is possible without costly modifications to the unit base ECONOMIZER OPERATION uses an enthalpy control to select suitable air quality for “free” cooling operation by measuring the dry bulb/humidity mix BAROMETRIC RELIEF-AIR PACKAGE exhausts stale indoor air during the economizer operation TWO-POSITION DAMPER PACKAGE includes a spring-return motor that closes off the outdoor air during unit shutdown LOW-AMBIENT operation for outdoor-air temperatures down to 35°F is standard A 0°F low-ambient kit is available as optional equipment UNIT FEATURES FACTORY-ASSEMBLED PACKAGE is a compact, fully self-contained cooling unit that is prewired, prepiped, and precharged for minimum installation time and expense TWO HIGH-EFFICIENCY, HERMETIC COMPRESSORS on sizes 120 & 150 provide 2-stage cooling to conserve energy by shutting down one compressor during light cooling loads These compressors are electrically and mechanically independent, therefore, cooling is still available even if one stage fails. A RUGGED, SERVICEABLE, SEMIHERMETIC COMPRESSOR with 33% capacity reduction is used on size 180. Part-load operation provides better humidity and temperature control of conditioned space MANUAL OUTDOOR-AIR DAMPER, which is standard equipment, provides up to 25% outdoor air for ventilation INTERNAL AND EXTERNAL PROTECTION against compressor overload and overheat conditions. HIGH- AND LOW-PRESSURE PROTECTION against abnormal operating conditions in the refrigerant cycle VERTICAL CONDENSER-AIR DISCHARGE prevents recirculation of hot condenser air and reduces the operating noise level PROTECTION AS REQUIRED BY N.E.C. for fan motors THERMAL- AND ACCOUSTIC-INSULATED air handling section COMPRESSOR ISOLATION MOUNTING eliminates vibration (noise) transmission to the building structure. CRANKCASE HEATERS AND FILTER-DRIERS are standard on both models ADJUSTABLE BELT-DRIVE BLOWER AND OPTIONAL DRIVES meet most air delivery requirements TWO-INCH FILTERS are standard. ELECTRIC HEATERS are available as optional equipment for operation on 208, 230, or 460 volts. SINGLE-POINT POWER CONNECTION to units with field-installed electric heaters Only one power supply with one disconnect switch is required WEATHERIZED CABINET of heavy-duty phosphated and zinc-coated steel Baked-on modified alkyd enamel finish is corrosion resistant and fade resistant. Interior surface of the evaporator compartment is insulated to help isolate the conditioned air from the outdoor ambient temperature. Form No. PDS 559D.120.2B 25% AIR OR ECONOMIZER HOOD I FPT DRAIN CONNECTION I FPT DRAIN CONNECTION FRONT VIEW 0 INDOOR AIRFLOW ' OUTDOOR AIRFLOW > ALTERNATE AIRFLOW ESPACE REQUIRED FOR SERVICE AND AIRFLOW DIMENSIONAL DRAWING RTU-82 NOM I5 x 4 TYP 4-PLACES OUTLINE OF UNIT 1" PLAN VIEW OF /ROOF CURB -ROOF OPENINGS DIMENSIONS (Inches) CURB P/N A 308450-201 14 308450-202 24 308450-203 24 NOTES. 1 ATTACH ALL DUCTWORK TO ROOF CURB 2 INSULATED PANELS, l-in THICK NEOPRENE COATED, l-l/2-Lb DENSITY SECTION A-A INSULATION FIELD-SUPPLIED ROOF MOUNTING CURB DIMENSIONS Size Operating Weight* Corner Weights A B C D 120 1210 264 424 322 200 150 1320 277 445 388 210 180 1450 317 508 385 240 *Add 150 lbs for unit with economizer REAR UNIT (TOP VIEW) FRONT P. D A84129 UNIT OPERATING AND CORNER WEIGHTS (lbs) INDOOR-AIR FAN MOTOR SIDE SUPPLY-/RETURN-AIR DISTRIBUTION RTU-83 RATINGS AND SPECIFICATIONS MODEL 559DP120 559DE120 559DP150 559DE150 S59DP180 559DE180 SERIES RATINGS & PERFORMANCE Cooling Total Capacity (Btuh) 119,000* 148,000}} 178,000}} Capacity Reduction 50% 50% 33% Rated Airflow (Fta/Min) 4000* 5000}} 6000}} Rated ESP (In. wc) 0.3* 0.35}} 0.35}} EER 8.2* 8.0« 8.2}} ARI Sound Rating 8.4t — — ELECTRICAL Unit Volts—Phase (60-Hz) 208/230-3 460-3 208/230-3 460—3 208/230-3 460—3 Operating Voltage Range 187-253 414—506 187—253 414—506 187—253 414—506 Unit Full Load Amps 62.7 27.8 71.6 31.8 87.4 51.3 Min Circuit Amps 70 35 81 35 105 55 Min Wire Size (75°C Copper)} 4 AWG 8 AWG 4 AWG 8 AWG 2 AWG 6 AWG Max Wire Length (Ft)} 148 300 130 263 161 253 Max Fuse Size (Amps) 80 35 90 40 125 60 Control Transformer, 24-V (VA) 48 48 48 48 48 48 COMPRESSORS, REFRIGERANT, & CONTROLS Compressor No. 1 (Type—RPM) Hermetic—3500 Hermetic—3500 Semihermetic—1750 | Rated Load Amps 24 10.5 27 11.6 61...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien