Anleitung Bryant, modell 556A

Hersteller: Bryant
Dateigröße: 109.09 kb
Dateiname: pf556a.24.1.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The unit features a copper tube, enhanced aluminum fin coil for a compact, low-profile appearance with vertical air discharge. FEATURES • SEER of at least 14.0 with specified Bryant equipment • AeroQuiet System • Earth-friendly refrigerant R-410A • High-pressure switch • Low-pressure switch • R-410A liquid-line filter drier • Compressor sound hood • Compressor start assist—PTC type • Compressor plug • Crankcase heater • Copper tube aluminum fin coil • External brass back seating service valves with sweat connections • R-410A hard shutoff TXV • Condenser coil grille • Electric ground lug LIMITED WARRANTY • 1-year parts only warranty on all parts • Additional 9-year warranty on compressor, no labor This product meets GREEN As an ENERGY STARSM Partner, SEAL criteria for manufac-Bryant Heating & Cooling Systuring, energy efficiency, tems has determined that this prod- sound levels and packaging. uct meets the ENERGY STAR It contains no CFCs or guidelines for energy efficiency. HCFCs. REGISTERED QUALITY SYSTEM —1— —2— NOTES: 1. Allow 30 in. clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55° F (unless low-ambient control is used) max 125° F. 3. Series designation is the 14th position of the unit model number. 4. Center of gravity . ACCESS PANEL 1 1 /4" AIR DISCHARGEAIR DISCHARGE AIR IN AIR IN AIR IN 2 1/ 2" AIR DISCHARGE 1 3 /4" 4 3 / 16" 3 /8-IN. DIA LIQUID LINE CONNH DIA VAPOR LINE CONN 8 3 / 16" 7 /8-IN. DIA HOLE FIELD POWER SUPPLY CONN 7 / 8-IN. DIA HOLE WITH 1 1 / 8-IN. DIA KNOCKOUT (ALL SIZES) AND 1 3 /8-IN. DIA KNOCKOUT (042 THRU 060 SIZES ONLY) 3 /8-IN. DIA TIEDOWN KNOCKOUTS (2) PLACES IN BASEPAN 10 1 /2" FIELD CONTROL SUPPLY CONN 1 9 / 16" L C F N G A B M K E D CL A97001 DIMENSIONS (IN.) UNITSIZE024 SERIESA UNIT DIMENSIONS MINIMUM MOUNTINGPAD DIMENSIONS26 X 32 A39-13/16 B30 C33 D5-1/16 E9-11/16 F27-15/16 G34-3/ 8 H5/ 8 KTBD LTBD MTBD N2-15/16 030 A 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/ 8 3/ 4 TBD TBD TBD 2-15/16 26 X 32 036 A 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/ 8 3/ 4 TBD TBD TBD 2-15/16 26 X 32 042 A 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/ 8 7/ 8 TBD TBD TBD 2-15/16 26 X 32 TBD—To Be Determined TESTED COMBINATION RATINGS* UNIT SIZE-SERIES 024-A INDOOR MODEL CJ5A/CK5A/CK5BA036 TOTAL CAPACITY BTUH 26,600 SEER EER 12.00 Factory- Supplied Enhancement TXV Standard Rating — Bryant Gas Furnace or Accessory TDR† 14.00 Accessory TXV‡ — 030-A CJ5A/CK5A/CK5BA042 30,500 TXV — 14.10 — 12.00 036-A CJ5A/CK5A/CK5BA048 36,500 TXV — 14.10 — 11.90 042-A CJ5A/CK5A/CK5BA060 42,000 TXV — 14.00 — 11.90 * Outdoor section/indoor section combination tested in accordance with DOE test procedure for electric air conditioners. † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD. ‡ Based on computer simulation. TXV must be R-410A compatible and hard shutoff type. EER—Energy Efficiency Ratio SEER—Seasonal Energy Efficiency Ratio TDR—Time-Delay Relay TXV—Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. 2. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 3. Do not apply with capillary tube coils as performance and reliability are significantly affected. RECOMMENDED TUBE DIAMETERS UNIT SIZE LIQUID TUBE DIAMETER (IN.) VAPOR TUBE DIAMETER (IN.) 0to50Ft Tube Length Long-Line Applications* 0to50Ft Tube Length Long-Line Applications* (Maximum Diameter) 024 3/8 3/8 5/8 3/4 030 3/8 3/8 3/4 7/8 036 3/8 3/8 3/4 7/8 042 3/8 3/8 7/8 1-1/8 * Tube diameters are for lengths up to 50 ft. For tubing lengths greater than 50 ft, consult the Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps Using R-410A Refrigerant. NOTE: Refrigerant tubes and indoor coils must be evacuated to 500 microns to minimize contamination and moisture in the system. METERING DEVICE UNIT SIZE INDOOR TXV* REQUIRED SUBCOOLING (°F) 024-A KSATX0201HSZ TBD 030-A KSATX0201HSZ TBD 036-A KSATX0301HSZ TBD 042-A KSATX0301HSZ TBD * TXV must be installed when indoor coil is not equipped with an R-410A approved TXV. TXV listed is for any approved coil combination. All TXVs are R-410A specific hard shutoff. TBD—To Be Determined SOUND RATING (DBA) UNIT SIZE-SERIES SOUND RATING 024-A 70 030-A 72 036-A 74 042-A 74 —3— SPECIFICATIONS UNIT SIZE-SERIES 024-A 030-A 036-A 042-A Operating Weight (Lb) 291 291 291 291 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187–253 Compressor— Rated Load Amps Locked Rotor Amps 13.5 14.7 15.4 18....


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien