Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Bryant, modell 463AAC005BA

Hersteller: Bryant
Dateigröße: 547.63 kb
Dateiname: 463aa_5_8_ba.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The rating plate is located on the right side of the unit, above the power cord If missing, a second nameplate is located on front chassis (also as known as basepan) Electric Shock Hazard To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing Energy-Saving Tips Your Room Air Conditioner unit is designed to be highly efficient and save energy. Follow these recommendations for greater efficiency. 1 Select thermostat setting that suits your comfort needs and leave the thermostat at that chosen setting 2 The filter is very efficient in removing airborne particles Keep air filter clean Normally, filter should be cleaned once a month More frequent cleaning may be necessary depending on outdoor and indoor air quality 3 Use drapes, curtains, or shades to keep direct sunlight from heating your room, but DO NOT obstruct the air conditioner Allow air to circulate around the unit without obstructions 4 Start your air conditioner before outdoor air becomes hot and uncomfortable This avoids an initial period of discomfort while the unit is cooling off the room 5 When outdoor temperature is cool enough, use HIGH or LOW FAN only (depending on your model) This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting Tools Needed for Window Installation Screw drivers: Both Philips and flat head Power drill: 1/8 inch diameter drill bit Pencil Measuring tape Scissors Carpenters level Adjustable wrench CAUTION A To avoid installation/operating difficulties, read the instructions thoroughly. Your Bryant Room Air Conditioner was designed for easy installation in a single or double-hung window NOTE: This unit is NOT designed for vertical (slider type) windows. NOTE* Save the shipping carton and packing materials for future storage or transport of the unit Please check the contents of hardware kit against the corresponding model check list, prior to installation of the unit See fists below, depending on model Fig. 11nstallation Hardware Model 463AAC005BA 3/4MScrews (10) (H 1/4"Screws (22) Top Channel(1) Bottom Chan nel(t) Shutter Clamp \ Mounting ' "7 Brackets(2) Foam Seal(4) Side Curtain RH(1) Side Curtain LH(1) Y Leveling legs (2) Fig. 1A Installation Hardware Model 463AAC008BA a 3/4"Screws (10) 1/4MScrews (18) Top Channel(i) Bottom Channel(t) (Factory Installed) Lock Washers(4) 1-1/2”x1/4 Boits(4) 1/4" Nuts(4) Shutter Clamp(2) Side Curtain RH(1) Side Curtain LH(1) a Mounting Brackets(2) Angle Brackets (2) Foam Seal(4) End Cap & Leveling Legs(2) — 5 - Installation Instructions CAUTION A Because the compressor is located on the controls side of the unit (right side), this side will be heavier and more awkward to manipulate Inadequate support on control side of the unit can result in personal injury and damage to your unit and property Therefore, it is recommended to have someone assist you during the installation of this unit F Your Bryant unit was designed to evaporate condensation under normal conditions However, under extreme humidity conditions, excess condensation may cause basepan to overflow to the outside The unit should be installed where condensation run-off cannot drip on pedestrians or neighboring properties G A drain connection(exciuding hose) is provided If you need to redirect condensation overflow (See Fig 23 on Page 12) 1. Select the Best Location A Your Bryant room air conditioner was designed to fit easily into a single or double hung window However, since window designs vary, it may be necessary to make some modifications for safe and proper installation B Make sure window and frame is structurally sound and free from dry and rotted wood C For maximum efficiency, install the air conditioner on side of the house or building which favors more shade than sunlight If the unit is in direct sunlight, it is advisable to provide an awning over the unit D Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit See (Dwg 1) The rear of the unit should be outdoors and not in a garage nor inside of a building Keep unit as far away as possible from obstacles obstructions and at least 30" above the floor or ground Curtains and other objects within a room should be prevented from blocking the air flow E Be certain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes Dwg 1 6 ~ I nsta 11 at i o n I nstructio n s 2. Preparation to remove the Air Conditioner Slide-Out Chassis (Model 463AAC005BA) A Tilt the unit on its back (Fig 1) be careful not to damage the drain on the back B Locate the finger indents on the underside of the interior air inlet grille(Fig 2) C Lift the air inlet grille(fully open) until it disengages from the top edge of the front pane\(Fig 2) D. Remove ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 463AAC008BA (547.63 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien