Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Goodman Mfg, modell CPC CONVERCIAL SS-CPC90-150

Hersteller: Goodman Mfg
Dateigröße: 1.26 mb
Dateiname: SS-CPC90-150.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Available as a factory-installed option on 3- to 12A-ton units. Hail guards are standard on 15- and 20-ton units. C • Stainless-Steel Heat Exchanger (CPG units only): A tubular heat exchanger made of 409-type stainless steel is installed in the unit. D • Ultra-Gold Condenser Coil: Offers increased corrosion resistance of the condenser coil. Not available for 15- & 20-ton units. • Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to J 6-ton units, cooling operation is extended from 60°F ambient temperature to 35°F outside S air temperature. On 7A- to 20-ton units, cooling operation is extended from 35°F ambient T temperature to 0°F outside air temperature. Economizers (Downflow): Based on air conditions, can provide outside air to cool the space. High Static Kits: Provides airflow in higher static applications. Electric Heat Kits (CPC and CPH units only): Available in all voltage options. Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet. Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit. Disconnect Switch (non-fused): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note that for air conditioning (CPC units) and heat pump models (CPH units), the appropriate electric heat kit must be ordered to be factory-installed along with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch (nonfused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position. Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit. Standard Aluminized Heat Exchanger Condenser Coil Hail Guard Condenser Coil Hail Guard Treated Condenser Coil (UltraGold) Condenser Coil Hail Guard Stainless-Steel Heat Exchanger Condenser Coil Hail Guard Treated Condenser Coil (UltraGold) Stainless-Steel Heat Exchanger Treated Condenser Coil (UltraGold) Stainless-Steel Heat Exchanger Treated Condenser Coil (UltraGold) Stainless-Steel Heat Exchanger 3 B 10 11 12 13 14 15 16 2 SS-CPC90-150 Product Specifications — 7% Tons Product Specifications CPC090 ***3B***B* CPC090 ***4B***b* CPC090 ***7B***b* Cooling Capacity Total BTU/h 90,000 90,000 90,000 Sensible BTU/h 64,000 64,000 64,000 EER / IEER 11.5 / 11.5 11.5 / 11.5 11.5 / 11.5 Decibels 82.0 82.0 82.0 AHRI Reference #s 5104770 5104770 5104770 Evaporator Motor / Coil Motor Type Belt Drive Belt Drive Belt Drive Indoor Nominal CFM 3,000 3,000 3,000 Indoor Motor FLA (Cooling) 5.0 2.5 2.3 Horsepower / RPM 1.5 / 1745 1.5 / 1745 1.5 / 1725 Piston Size (Cooling) 0.078 0.078 0.078 Filter Size (Qty) (4) 16"x20"x2" (4) 16"x20"x2" (4) 16"x20"x2" Drain Size (NPT) 4" 4" 4" R-410A Refrigerant Charge Cir #1 & #2 175 oz. 175 oz. 175 oz. Evaporator Coil Face Area (ft2) 8.9 8.9 8.9 Rows Deep / Fins per Inch 4 / 16 4 / 16 4 / 16 Belt Drive Evap Fan Data # of Wheels (D x W) 1 (15"x12") 1 (15"x12") 1 (15"x12") Motor Sheave / Blower Sheave VL40 / AK74 VL40 / AK74 VL40 / AK74 Belt AX51 AX51 AX51 Condenser Fan / Coil Quantity of Condenser Fan Motors 2 2 2 Horsepower - RPM % - 1075 % - 890 % - 1,075 Fan Diameter / # Fan Blades 22 / 4 22 / 4 22 / 4 Outdoor Nominal CFM 7,200 7,200 7,200 Face Area (ft2) 36 36 36 Rows Deep / Fins per Inch 2 / 22 2 / 22 2 / 22 Compressor Quantity / Type 2 / Scroll 2 / Scroll 2 / Scroll Stage 1 1 1 Electrical Data Voltage-Phase-Frequency 208/230-3-60 460-3-60 575-3-60 Quantity of Compressors 2 2 2 Compressor RLA / LRA 13.1 / 83.1 6.1 / 41.0 4.4 / 33.0 Max External Static 1.0" 1.0" 1.0" Outdoor Fan HP / RLA (2) % / 1.4 (2) % / 0.8 (2) % / 0.6 Total Unit Amps 34.0 16.3 12.3 Min. Circuit Ampacity1 37.3 17.8 13.4 Max. Overcurrent Protection (amps)2 50 20 15 Entrance Power Supply Locating Locating Locating Entrance Control Voltage Dimple Dimple Dimple Operating Weight (lbs) 975 975 975 Ship Weight (lbs) 1000 1000 1000 1 Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 2 May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed. SS-CPC90-150 3 Product Specifications Product Specifications — 8% Tons CPC102 ***3B***a* CPC102 ***4B***a* CPC102 ***7B***a* Cooling Capacity Total, BTU/h 102,000 102,000 102,000 Sensible BTU/h 70,380 70,380 70,380 EER / IEER 11.3 / 11.4 11.3 / 11.4 11.3 / 11.4 Decibels 83 83 83 ARI Reference #s 5104771 5104771 5104771 Evapoartor Motor / Coil Motor Type Belt Drive Belt Drive Belt Drive Indoor N...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien