Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung Freecom Technologies, modell PORTABLE AIR CONDITIONER RCS-M1000T

Hersteller: Freecom Technologies
Dateigröße: 91.54 kb
Dateiname: 4a53c923-8bfd-429e-afbb-04c1d2635c77.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Il doit etre utilise en position verticale. Si pour une raison quelconque vous deviez le coucher sur le cote, ne le remettez en route que deux heures environ apres l'avoir replace en position verticale. Ceci permettra le repositionnement correct des liquides et gaz du systeme refrigerant. INSTRUCTIONS DE SECURITE A lire attentivement avant utilisation Securite • Ne pas arreter l'appareil en debranchant la prise de courant en cours de fonctionnement. Ceci pourrait endommager le circuit de controle (dommage exclu de la gantie). Utilisez toujours le bouton "ON/OFF" du tableau de commande. • Ne pas glisser le cordon d'alimentation sous la moquette ou des tapis. • Ne pas recouvrir l'appareil avec des vetements, serviettes ou objets similaires. • Ne pas obstruer l'entree ou la sortie d'air, ni bloquer les deflecteurs oscillants. • Ne pas debrancher l'appareil si vos mains sont humides : ilyarisque de choc electrique. • Ne pas placer d'objets sur le dessus de l'appareil. Positionnement • Ne pas coucher l'appareil sur les cotes : il doit etre maintenu en position verticale. • Ne pas placer l'appareil pres d'une source de chaleur, ou l'exposer directement aux rayons du soleil. Proteger la piece de l'exposition directe du soleil en fermant rideaux et stores, etc...pour ameliorer le rafraichissement. • Ne pas placer l'appareil pres de rideaux qui risquent de bloquer l'entree ou la sortie d'air (distance minimale: 50 cm). • Verifier que l'appareil est place sur une surface plane. Utilisation • Ne pas transporter l'appareil en fonctionnement. • Ne pas essayer de modifier ou de reparer vous-meme l'appareil : ceci peut etre dangereux et annulera la garantie. • Ne pas utiliser l'appareil sans filtre a air. MAINTENANCE AND CLEANING (contd.) Cleaning Air Filters This unit has two air filters. For best results and maximum performance, clean both filters every two weeks, or as required by environmental conditions. CAUTION: Neglect or failure to regularly clean the filters will result in poor efficiency, reduced performance, possible damage to the unit, and voiding your warranty. 1. Press “POWER ON/OFF” button to stop unit if it is operating. Unplug power cord from outlet. 2. Locate small square openings in the back of the unit. Place thumb into one opening and cup fingers against air filter handle. Gently pull air filter straight out of unit. Repeat for air filter on opposite side. 3. Place air filter on a flat, level surface so “dirty” side of filter faces up. Using a brush or nozzle vacuum attachment, gently vacuum “dirty” side of each filter. Turn each filter over and vacuum other side. Use care not to damage or puncture the filter mesh. DO NOT use brushes, brooms, or other course materials to clean the filters. 4. Hold each air filter, “dirty” side down, under cool, running water. DO NOT use hot water, harsh detergents, chemicals, solvents, gasoline or any other abrasive materials or household items to clean the filters. Be sure to rinse all residue from the air filter mesh. Carefully shake air filter to remove excess water. Allow air filter to dry completely before reinstalling into unit. WARNING: Forcing filters improperly into unit may cause damage to the filter section of the cabinet. Repair due to improper filter installation is not covered under warranty. 5. From back of unit, gently slide filter with wider handle into long, narrow opening on right. DO NOT force air filter into place. Gently slide filter with thinner handle into opening on left. When properly installed, both air filters will smoothly complete the curves at the back of the unit. MAINTENANCE AND CLEANING Emptying Condensate Water Tank When the condensate water tank is full, the “FULL TANK” indicator light will flash,the unit will sound several initial warning beeps, and the unit will automatically turn off. NOTE: If emptying water tank before “full tank” alert, press “POWER ON/OFF” button to stop unit if it is operating. 1. Unplug power cord from outlet. Allow unit to remain off for 2-3 minutes. 2. Grasp the condensate water tank handle opening and carefully pull water tank straight out of unit. 3. Carefully carry the tank to a sink or tub and empty its contents. Use water and a mild detergent to rinse and clean the inside and outside of the tank. Dry tank completely and be sure tank is completely empty. 4. Hold water tank by handle and carefully push tank straight into opening in side of unit. Push in until tank is flush with housing. 5. Plug power cord into outlet. Press “POWER ON/OFF” button. If the condensate water tank is improperly installed, the FULL TANK indicator light will flash, several initial warning beeps will sound, and the unit will not turn on. Double check that water tank is properly installed. Press “POWER ON/OFF” button again to start unit. IMPORTANT SAFETY INFORMATION PLEASE READ AND FOLLOW ALL SAFETY INFORMATION AND INSTRUCTIONS BEFORE OPERATING YOUR NEW FREECOM AIR CONDITIONER. WARNING: ELECTRICAL SHOCK HAZARD. Failure to follow ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - PORTABLE AIR CONDITIONER RCS-M1000U (91.54 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien