Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung LG, modell T18LH

Hersteller: LG
Dateigröße: 2.18 mb
Dateiname:
Unterrichtssprache:en
Fotos und technische Daten  LG  T18LH
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Features WARNING: This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features. Anti-bacteriaAnti-bacteria Heat Pump Model Cooling Model Remote . Controller Air Outlet Air. Intake Signal Receptor Signal Receptor Owner's Manual 7 Electrical Safety Electrical Safety WARNING: This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet. Preferred method Ensure proper ground . exists before use WARNING: Do not cut or remove the grounding prong from the power wire. WARNING: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring. WARNING: If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician. 8 Ceiling Cassette Air Conditioner Operating Instructions Operating Instructions Indoor Unit, Outdoor Unit Anti-bacteriaAnti-bacteria Heat Pump Model Cooling Model Remote . Controller Indoor Unit Air Outlet Air. Intake Signal Receptor Signal Receptor Signal Receptor Receives the signals from the remote control. (Signal receiving sound: two short beeps or one long beep.) Operation Indication Lamps On/Off : Lights up during the system operation. Filter Sign : Lights up after 2400 hours from the time of first operating unit. (Refer to page 28.) Timer : Lights up during Timer operation. Defrost Mode : Lights up during Defrost Mode or Hot Start operation. (Heat pump model only) Outdoor Unit : Lights up during outdoor unit operation. Operation (Cooling model only) Forced : Operation procedures when the remote control Operation can't be used. ENGLISH Owner's Manual 9 1. Operation indication screen 2. Swirl button 1 14 5 3. 2nd F button 4. Timer set/cancel Program/Week/Holiday Hour/Min/SET/Clr/Ventilator 2 3 6 7 5. Set temperature button 6. ON/OFF button 4 8 9 10 11 12 13 7. Fan operation 8. Operation mode selection button 9. Fan speed button 10. Horizontal/Vertical air flow direction button 11. Room temperatur/filtersign release button 12. Plasma/Heater button 13. Time reset button 14. Operation lamp Timer Program Hour Cancel 2ndF Week Holiday Set/Clr Min RESET PLASMA ZONE 1234 Operation unit No Func HumidifyJET SLo AU TO AUTO SWING OPERATION FAN SPEED Program set SUB FUNCTIONSET TEMP Room Temp HI MED LO Heater Defrost Filter Preheat Out door Time Timer On Set no. Time Off 01 03 05 07 09 11 13 15 17 19 21 23 2ndF Operating Instructions Name and Function of Remote Controller 10 Ceiling Cassette Air Conditioner Operating Instructions Wireless Remote Controller (optional) This air-conditioner is equipped with wired remote controller basically. But if you want to be available with wireless remote controller, you pay for it. 1. START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. 2. OPERATION MODE SELECTION BUTTON Used to select the operation mode. 3. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. 4. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high and CHAOS. 5. JET COOL Used to start or stop the speed cooling/heating. (Speed cooling/heating operates super high fan speed.) 6. CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. 7. ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. 8. TIME SETTING BUTTONS Used to adjust the time. 9. TIMER SET/CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation. 10. SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation. 11. AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating. 12. ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. 13. PLASMA(OPTIONAL) (opened) Used to start or stop the plasma-purification function. 14. RESET BUTTON Initialize remote controller. 15. 2nd F Button Used prior to using modes printed in blue at the bottom of buttons. . The wireless remote controller does not operate the swirl mode and super low fan speed. CAUTION:of handling the Remote Controller • Aim at the signal receiver on the wired remote controller so as to operate. • The remote control signal can be received at a distance of up to about 7m. • Be sure that there are no obstructions between the remote controller and the signal receptor. • Do not drop or throw the remote controller. • Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any other heat source. • Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation. (ex:electronic quick start, ELBA, inverter type fluorescent lamp) ON OFF CANCEL SET Flip-up door. Signal transmitter 5 1 3 10...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - T24LH (2.18 mb)
Splitgeräte - T28LH (2.18 mb)
Splitgeräte - T36LH (2.18 mb)
Splitgeräte - T48LH (2.18 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien