Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung LG, modell DK-H1208C00

Hersteller: LG
Dateigröße: 3.29 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION SET TEMP SUB FUNCTION Heating Operation Operation Display HI AUTO SWING ZONE Operation unit Program set Room Temp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no. Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION SET TEMP SUB FUNCTION Heating Operation Mode(Heat pump model only) Select Heating Operation. Press the Operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted in the arrow direction. 2 3 Set the temperature. This air-conditioner is set to the hot start control in order not to discharge the cold air during the heating operation. This time, the remote controller indicates ‘Preheat’. 4 If the outdoor temperature is too low during the heating operation, this air-conditioner is set to the defrosting operation and the remote controller indicates ‘Defrost’. 5 1 Press the On/Off Button. • The temperature can be set within a range of 16°C~30°C by 1°C. Care and Maintenance Care and Maintenance CAUTION: Before performing any maintenance, turn off the main power to the system. You can do some of the periodic maintenance for your unit yourself; this includes cleaning air filters, cleaning unit cabinet, clearing the condenser coil, and conducting a general unit inspection on a regular basis. WARNING: Before removing access panels to service unit, disconnect power supply. Failure to disconnect power before attempting any servicing can result in severe injury or death. ANTI-BACTERIA-Air Filters This product has anti-bacteria washable filters. It is very important to keep air filters clean in the central duct system. Be sure to inspect them at least once each month when the system is in constant operation. (In new buildings, check the filters every week for the first 4 weeks.) Washable type filters can be cleaned by washing with a mild detergent and water. Ensure that the filters are thoroughly dried before reinstalled them in the unit (or duct system). Condenser coil Unfiltered air circulates through the unit's condenser coil and can cause the coil's surface to become clogged with dust, dirt, etc.. To clean the coil, vertically (i.e., along the fins) stroke the coil surface with a soft bristled brush. Keep all vegetation away from the condenser coil area. Maintenance Performed by Serviceman-Cooling Season To keep your unit operating safely and efficiently, the manufacturer recommends that a qualified serviceman check the entire system at least once each year, or more frequently if conditions warrant. Your serviceman may examine these areas of your unit: 1. Filters (for cleaning) 2. Motors and drive system components 3. Condenser coils (for cleaning) 4. Safety Controls (for mechanical cleaning) 5. Electrical components and wiring (for possible replacement or connection tightness) 6. Condensate drain (for cleaning) 7. Inspect the unit duct connections to ensure they are physically sound and sealed to the unit casing. 8. Inspect the unit mounting support to see that it is sound. 9. Inspect the unit to ensure there is no obvious deterioration. Maintenance Performed By Serviceman-Heating Season Complete the unit inspections and service routines described below at the beginning of each heating season. • Inspect the controller panel wiring to verify that all electrical connections are tight and that wire insulation is intact. 18 Single Package Type Air Conditioner Care and Maintenance When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. 1. Operate the air conditioner on Air circulation mode for 2 to 3 hours. • This will dry out the internal parts. 2. Turn off the circuit breaker. CAUTION: Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire. When the air conditioner is to be used again. 1. Clean the air filter and re-install it in the indoor side. On the fillter access panel at the left side of the unit, a “Filter access panel” label is attatched. 2. Check that the air inlet and outlet of the indoor/outdoor unit are not blocked. Operation Tips Do not overcool the room. Keep blinds or curtains Clean the air filter regularly. closed. This is not good for your health and Do not let direct sunshine enter the Blockages in the air filter reduce the wastes electricity. room when the air conditioner is in airflow and lower cooling and operation. dehumidifying effects. CAUTION Before removing access panels to draw out air filters, disconnect Make sure that the doors Ventilate the room power supply. Since the fan rotates at high speed, it and windows are shut tight. occasionally. may cause a serious injury Avoid opening doors and windows Since windows are kept closed, it is Clean at least once every as much as possible to keep the a good idea to open them and month using a vacuum cool air in the room. ventilate the room now and...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - DK-H1808C00 (3.29 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien