Login:
Stimmen - 2, Durchschnittliche Bewertung: 4.5 ( )

Anleitung DeLonghi, modell Pinguino PAC 250 U

Hersteller: DeLonghi
Dateigröße: 2.14 mb
Dateiname: f7e78ba2-2d4a-4f80-9b50-b9ab5ba8f0be.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


4) Select the desired function as shown in the chart overleaf. The unit will now switch on and off each day at the selected times. Note: To override the programmed operating times, simply press the ON/OFF key. NON-PROGRAMMED MODE 1) B TIMER button must be pressed 2) Select the desired function as shown in the chart on the following page. 11 9 4 10 arrow pointer 11 10 9 4 OFpunezraiotninagm etinmtoe N.B: For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness. We therefore recommend that when starting up the appliance, the thermostat be turned to maximum (thick green line = maximum cold). When the desired temperature has been reached, turn the thermostat slowly away from the maximum cooling position until the appliance switches off. Leave the thermostat in this position. The air-conditioner is now programmed to maintain the exact temperature at all times. After switching the appliance off, wait at least 3 min. before switching on again. eg. from 9 to 11 a.m. HOW TO START UP THE CONDITIONER (see control panel on the previous page) Plug the appliance into the mains. Select the “programmed” or “non pro- grammed” mode (see previous page) Select the fan speed required pressing “Fan speed” key C. Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. Cold. Press key A (ON/OFF). ON/OFF signal lamp (conditioning) will come on. The appliance comes on. If not, refer to pag. 14. To switch off the appliance, press key A (ON/OFF main switch). AIR-CONDITIONING 12 MAINTENANCE PRECAUTIONS During cleaning and normal maintenance operations remember to disconnect plug. Under no circumstances should appliance be washed with runing water. Damage could be caused to the electrical circuit. CLEANING OF EXTERNAL HOUSING .... .... QQ QQ .. .. Clean with a damp cloth and dry thoroughly with a clean dry cloth. Use only mild soap and water. Do not use chemical cleaners. CONTROLS AT THE BEGINNING OF THE SEASON Carefully follow installation procedure. Check for any defects in power cord and plug. CLEANING OF COLLECTING TRAY 4) Remove plug from drainage tube, located at rear of appliance and emty water into the tray for water drainage supplied as accessory. 5) When draining is finished, replace plug of drainage tube. 6) Remove sediment from the collecting tray by rubbing with a cloth. .... .... QQ QQ .. .. 1) Open water container compartment door and remove tank. 2) Keep the air-conditioner working until the water level indicator light goes on. 3) Switch off the air-conditione and disconnect electrical plug. fig. 15 fig. 16 fig. 17 fig. 18 fig. 19 fig. 20 fig. 21 13 AIR FILTER CLEANING Maintenance of air filter A clogged air filter reduces the quantity of circulating air and the efficiency of the appliance. Clean filter every week using a vacuum cleaner. Removal and replacement of air filter Gently pull filter upwards. Push down to replace. Cleaning procedure To remove dust deposited on filter, use a vacuum cleaner. If it is very dirty, soak in lukewarm water and rinse thouroghly. The temperature of the water must be kept below 104°F. After washing, leave filter to dry before replacing. END OF SEASON OPERATIONS 1) Disconnect plug. 2) Remove tank and empty it. 3) Some water may remain into the tank. To avoid unpleasant odors, pour two spoons of bleach into the tank. 4) Drain water from collecting tray. 5) Remove exhaust hose. 6) Clean filter and dry well before replacing. 7) Cover appliance with a polyethylene bag to prevent dust from entering. You can use the polyethylene bag included into the packaging. fig. 22 Remove dust with a vacuum cleaner Rinse with running water fig. 23 fig. 24 fig. 25 fig. 26 PERIODIC MAINTENANCE Calcium deposits may build up on some working parts of Pinguino during operation. Monthly cleaning (more often in hard water areas) should be done per the following procedure: -Unplug the machine. Remove the water tank. -Remove drainage tube plug and empty water. Replace drainage tube plug and add one quart of clean water to the collecting tray. -Empty 8 Fl. Oz. of Descaling Fluid into the collecting tray. Plug in the machine and operate for about half an hour. Turn off and unplug machine. -Drain the remaining liquid and re-plug the drainage tube. -Refill the tank with clean water and replace in the machine. -Plug in and turn on the machine. While the air-conditioner is operating, unplug the drainage tube and drain until the water looks clean. Replace the drainage tube plug. TROUBLESHOOTING SYMPTOMS CAUSE SOLUTION The Pinguino does not -power failure function: -plug is disconnected -insert plug -ON/OFF switch is off -switch on -Timer key is in STOP position -release the TIMER key The Pinguino does not function -function fault warning -exhaust hose blocked -Check for obstruction of air light is on (pag. 10 outlet vent “Alarm” light) -exhaust hose twisted or bent -eliminate irregularities After correcting problem, press reset button (see pag. 5) -ventilation...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien