Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung DeLonghi, modell PINGUINO PAC600T

Hersteller: DeLonghi
Dateigröße: 393.55 kb
Dateiname: f3412d92-9f70-40c5-8e85-cb8e68f686fb.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


. . .pag. 4 • Mode d’emploi et d’entretien . . . . .pag. 16 • Instrucciones de uso . . . . . . . . . .pag. 28 • Manual de instrucoes . . . . . . . . . .pag. 40 PAC600TPAC600T • Use and maintenance manual . . . .pag. 4 • Mode d’emploi et d’entretien . . . . .pag. 16 • Instrucciones de uso . . . . . . . . . .pag. 28 • Manual de instrucoes . . . . . . . . . .pag. 40 Important safeguards • Use this appliance only as described in this instruction manual. As with any electrical appliance, whilst the instructions aim to cover as many eventualities as possible caution and common sense should be applied when operating and installing this air conditioner. • This appliance has been manufactured to cool and de-humidify domestic environments and should not be used for other purposes. • It is dangerous to alter or modify the unit's characteristics in any way. • The appliance must be installed in line with the relevant national legislation. • Should repairs be necessary, contact the nearest authorised Repair Service Centre. Unauthorised servicing can be dangerous. • This appliance is to be used by adults only; keep away from children. • In the case that the power cable becomes damaged, this must be substituted only by specialised personnel authorised by the manufacturer. • Always ensure the appliance is earthed. If you have any doubts check with a qualified electrician. • Avoid using extension leads with the unit. • Before cleaning or maintenance operations, always unplug the unit from the socket. • Do not pull on or place strain on the power cable when moving the appliance. • The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources. • Do not rest hot or heavy objects onto the appliance. • Remember to perform the descaling procedure at the end of each season (see page 13). In areas where the water is particularly hard (rich in minerals), the use of a commercial anti-lime product added to the water is recommended. This can be requested from De’Longhi LTD. • Clean the filters at least once a week. • Avoid using heaters near the unit. • The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie horizontally. • Before transporting the unit drain the condensation collecting-tray and tank. After transportation, wait at least 1 hour before switching on the unit. • The packaging materials can be recycled. You are therefore recommended to place them in the special containers for differentiated waste collection. SAVE THESE INSTRUCTIONS How does your Pinguino work ENGLISH During the summer, optimum comfort is achieved with a temperature of around 75°F (24 °C) and 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over fitted models is that they can be moved from one room to removing excess heat and moisture before being again into the room. In single unit models, a small amount of this air is used to cool the refrigerant gas, then the hot and moist air is discharged outside. another in the home or even transferred between different buildings. The hot air in your room is passed through a coil cooled by refrigerant gas, discharged 5 Setting up The following instructions will help you set up your air conditioning unit as efficiently as possible. 27 AIR CONDITIONING WITHOUT INSTALLATION • With a double casement window, use the FOR INSTANT TEMPORARY USAGE suckers provided to hold the two halves of the window together (fig. C). With just a few simple operations, Pinguino will restore comfortable conditions in your room: • Fix the exhaust hose 25 to the coupling on the back of the unit as shown in figure A. Fix the window attachment to the end26 1 2 A of the hose 25 . • Place the unit near a window or door. • Open the window, or the door slightly and• 26place the window attachment as shown in figure B. • Pinguino is equipped with an adjustable window bracket. If you have a sash window, place the bracket on the window sill, extend the bracket fully within the window frame and lower the window onto the bracket. Insert the nozzle of the exhaust hose into the slot, then connect the hose to the air conditioner (Fig. D).Thanks to the wing nut, it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket so to allow a correct installation of the exhaust hose. window bracket D B 7 ENGLISH Setting up AIR CONDITIONING WITH INSTALLATION For more efficient use Pinguino can also be semi-permanently installed • Fit the flange supplied to the hole. • Fix the hose to the coupling on the back of the unit (figure A). • Attach the end of the hose to the flange 24 as shown in the figure F. 25 25 24 To install, proceed as follows: • Make a hole in a outside wall or through the glass of a window. Check the height and dimensions given in figure E 12" 12" 30 cm 30 cm 4" 100 MAX 47" (120 cm) MIN 12" ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien