Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung DeLonghi, modell PAC260

Hersteller: DeLonghi
Dateigröße: 398.87 kb
Dateiname: 86a82c0e-62df-4db6-90ed-504ac8985f2c.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


. . . . . . . . .page 2 Mode d’emploi et d’entretien . . . . . . . . . . .page 16 Instrucciones de uso . . . . . . . . . . . . . . . .pagina 29 Istruzioni per l’uso . . . . . . . . . . . . . . . . . .pagina 43 PAC260GB 24-04-2003 16:33 Pagina 2 Important Safeguards When using electrical appliances, basic safety precautions should always be followed, including the following: -Read all instructions. -To protect against fire, electrical shock and personal injury, do not immerse cord, plug or appliance in water or other liquid. -Close supervision is necessary when any appliance is used by or near children. -Do not operate with a damaged cord or plug, or after the appliance malfunctions, or has been damaged in any manner. Return the appliance to the nearest authorized service facility for examination, repair or adjustment. -The use of accessory attachments or spare parts not recommended by the appliance manufacturer may result in fire, electrical shock or personal injury. -Do not use outdoors. -Do not use the appliance for other than the intended use. -Do not place any strain on the power cord. Avoid twisting and/or tan gling. -Ensure that outlet vent of exhaust hose is kept free of debris and obstruction. -Ensure that ventilation holes on the rear of the machine and front louvers are not blocked. -The Pinguino should not be installed where the atmosphere could contain combustible gases. -Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat. -Wait at least 3 minutes before restarting, after the air conditioner has been switched off or the thermostat setting changed. -Before moving the air conditioner, empty water from collectiong tray (see instructions for drainage at page 13). -Do not place hot or heavy objects on the appliance. -Clean air filter every week (see instructions at page 13). -Important: If you need to use an extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). SAVE THESE INSTRUCTIONS 2 PAC260GB 24-04-2003 16:33 Pagina 3 Dear user, We thank you for purchasing the Pinguino air conditioner and congratulate you on your wise choice. For optimal results please read this manual carefully before installing or operating. We know that the Pinguino will maintain pleasingly comfortable environment at all times. With best wishes, De Longhi S.p.A. If you have any questions about the operation or service of your Pinguino, please call our toll-free service number 1-800-322-3848. or visit our internet site: for general overlook of De’Longhi group visit: 3 PAC260GB 24-04-2003 16:33 Pagina 4 Specifications Power supply voltage V see rating label Frequency Hz 60 Cooling capacity: (*) see rating label Fan speeds 2 Dehumidification quotient (*) see rating label Dimensions: width in. (mm) height in. (mm) depth in. (mm) 221/31 (560) 30 (735) 159/16 (390) Net weight lb. (kg) 97 (44) *Data according to pending standard testing procedures subject to review by the U.S. Dept. of Energy. A HE (High efficiency) system with low energy consumption has been installed on this appliance. This system needs about 4 minutes, once the appliance has been started, to produce cold air. OPTIMUM OPERATING RANGE ROOM TEMPERATURE 70°F - 90°F ROOM HUMIDITY FACTOR 50% - 80% RH POWER SUPPLY FREQUENCY 60 HZ VOLTAGE 115V 4 PAC260GB 24-04-2003 16:33 Pagina 5 Illustrated main features list Air outlet grid Timer cover (to adjust the timer slide cover sideways) Castor Castor stops Water collecting tray Air filter Air intake grid Exaust hose Power cord comp. Reset button Drainage tube 5 PAC260GB 24-04-2003 16:33 Pagina 6 Accessories DESCRIPTION SUPPLIED Exhaust hose 1 Stopper + flange 1 Caster stop 2 Window nozzle 1 Adjustable window and door bracket 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in table are included. 6 INSIDE OUTSIDE 3” 1 / 2 A2 INSIDE OUTSIDE 3” 1 / 2 A2 PAC260GB 24-04-2003 16:33 Pagina 7 Setting up PERMANENT INSTALLATION The Pinguino accessories include two sets of flanges and stoppers, to be mountedl in different locations (two different rooms). Once installed, these vents (flanges) are the only items needed for using Pinguino. Permanent installation outlet holes must be in an exterior wall and opening diameter should not exceed 3”1/2. INSIDE fig. 2 OUTSIDE 3” 1 / 2 A1 in a window pane INSIDE fig. 4 OUTSIDE A3 through the wall 3” 1 / 2 1” fig. 1 fig. 3 through the wooden base-section of a door or window In case of fixed installation, air discharged from rear hose has been extracted from the room where the appliance is installed. Check that the room (especially if small) is not “air-tight”; a drop in pressure would cause irregular functioning, which could consequently activate reset switch. Air entering through door and window cracks is normally sufficient. If deemed, necessary leave a door ajar (approx. 1 cm is enough). 7 PAC260GB 24-04-2003 16:33 Pagina 8 fig. 7 window bracket Setting up TEMPORARY INSTALLATION Note: In both...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien