|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
When it has been increased by 2°C (after 2 hours), the temperature is maintained for four hours. 2“C rc Set 1 ' TEMP. St tin 1 hr 2hr 6hr art Stop ne time To Cancel the Sleep Timer If you no longer wish to use the Sleep Timer that you have set, you can cancel it at any time. Press the button. Result: ♦ The indoor unit beeps. ♦ The ^ is no longer displayed. ♦ The air conditioner operates normally. e-18 Operating Recommendation Here is a recommendation that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner starts up again automatically. Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped. Low temperatures A water leak or some other malfunction may occur if the heat exchanger freezes. High humidity levels Water may condense on and drip from the surface of the indoor unit if it is used for long periods. Mode Outdoor Temperature Indoor Temperature Indoor Humidity Cooling 21°C to 43°C approx. 18°C to 32°C approx. 80% or less Drying 18°C to 43°C approx. 18°C to 32°C approx. - # If the cooling operation is used at over 33°C(indoor temperature), it does not cool at its full capacity. ENGLISH Operating Your Air Conditioner Without the Remote Control * The design and shape are subject to change according to the model. Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken. 1 ** 07/09/12/14** Slide the lower front grille down. ** 18/24 ** Open the upper front grille by pulling right and left sides of the grille. Slide the lower front grille down. 2 To switch the air conditioner on, press the On/Off switch on the right side of the indoor unit. Result: ♦ The Operation indicator on the indoor unit comes on. ♦ The indoor unit beeps. ♦ The air conditioner starts up in the most suitable mode for the room temperature: Room Temperature 21°C or above Operating Mode Cool 3 To switch the air conditioner off, press the On/Off switch again. Even if the air conditioner has been switched on via the On/Off switch, operations can still be controlled using the remote control as usual. (e-20| Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not operate at all ♦ Check that the breaker used for the air conditioner is switched on. ♦ Check that the operation indicator on the indoor unit is on; if necessary press the $> (On/Off) button on the remote control. ♦ Check whether the Timer indicator on the indoor unit is switched on. If so: - Wait until the switch-on time is reached and the air conditioner starts up automatically - Cancel the timer (see pages 16 and 17 for further details) The air conditioner does not operate with the remote control ♦ Check that there are no obstacles between you and the indoor unit. ♦ Check the remote control batteries. ♦ Check that you are close enough to the indoor unit (seven meters/ yards or less). No beep is heard when you press the (On/Off) on the remote control ♦ Check that you are pointing the remote control at the remote control sensor in the right of the indoor unit. ♦ Replace the remote control batteries if necessary. The air conditioner does not cool ♦ Check that the correct operating mode has been selected (AUTO, COOL). ♦ The room temperature may be too low. ♦ Dust may be blocking the air filter guard; refer to page 22 for cleaning instructions. ♦ Check that there is no obstacle in front of the outdoor unit. The fan speed does not change when you press the button ♦ Check that the operating mode is set to COOL or FAN ; in the AUTO mode, the fan speed changes automatically and in the DRY mode, it is set to AUTO. The air flow direction does not change when you press the & button ♦ Check that the air conditioner has been switched on; if necessary, press the (On/Off) button on the remote control. The timer is not correctly triggered ♦ Check that the timer has been programmed correctly; see pages 16 and 17. Odour is permeated in the room during air conditioning ♦ Air the room. e-21 ENGLISH Cleaning Your Air Conditioner For the best use of your air conditioner, you must clean it every two weeks regularly to remove the dust that accumulates on the air filter. IIMPORTANT Before cleaning your air conditioner, ensure that you have switched off the breaker used for the unit. 1 ** 07/09/12/14** Slide the lower front grille down. ** 18/24 ** Open the upper front grille by pulling right and left sides of the grille....
Dieses Handbuch ist für folgende Modelle:Splitgeräte - AS12S4GE7/FMC (1.18 mb)
Splitgeräte - IAS12S4GE7/FMC (1.18 mb)
Splitgeräte - IAS18S0GEA5SMR (1.18 mb)