|
Anleitung Zusammenfassung
If the resistance of the return air duct is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Unitary Products Group 9 173858-YIM-A-0306 TABLE 6: D1EB036 SUPERHEAT CHARGING (IMPERIAL) OUTDOOR TEMPERATURE SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,300 CFM INDOOR WB TEMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.1 21.6 22.1 22.7 23.2 23.8 24.3 25.3 26.4 26.9 27.4 70 19.5 20.0 20.6 21.1 21.7 22.2 22.8 24.0 25.1 25.7 26.3 75 17.9 18.5 19.0 19.6 20.2 20.7 21.3 22.6 23.9 24.6 25.2 80 16.3 16.9 17.5 18.0 18.6 19.2 19.8 21.2 22.7 23.4 24.1 85 14.7 15.3 15.9 16.5 17.1 17.7 18.3 19.9 21.4 22.2 23.0 90 1 3.1 13.8 14.4 15.1 15.8 16.4 17.1 18.7 20.3 21.2 22.0 95 11.5 12.2 12.9 13.7 14.4 15.2 15.9 17.6 19.3 20.1 20.9 100 9.1 9.6 10.2 10.7 11.2 11.8 12.3 15.0 17.6 18.9 20.2 105 6.7 7.1 7.4 7.7 8.1 8.4 8.8 12.4 16.0 17.8 19.6 110 - - - - - 5.0 5.2 9.7 1 4.3 16.6 18.9 115 - - - - - - - 7.1 12.6 15.4 18.2 TABLE 7: D1EB036 SUPERHEAT CHARGING (METRIC) OUTDOOR TEMPERATURE (°C) SUPERHEAT AT COMPRESSOR SUCTION (°C) AIRFLOW = 0.61 M3/S INDOOR WB TEMPERATURE (°C) 13 14 15 16 17 18 19 21 22 23 24 18 11.7 12.0 12.3 12.6 12.9 13.2 13.5 14.1 14.7 14.9 15.2 21 10.8 11.1 11.4 11.7 12.1 12.4 12.7 13.3 1 4.0 1 4.3 1 4.6 24 9.9 10.3 10.6 10.9 11.2 11.5 11.8 12.6 13.3 13.6 14.0 27 9.1 9.4 9.7 10.0 10.4 10.7 11.0 11.8 12.6 13.0 13.4 29 8.2 8.5 8.8 9.2 9.5 9.8 10.2 11.0 11.9 12.3 12.8 32 7.3 7.6 8.0 8.4 8.8 9.1 9.5 10.4 11.3 11.8 12.2 35 6.4 6.8 7.2 7.6 8.0 8.4 8.8 9.8 10.7 11.2 11.6 38 5.0 5.3 5.6 5.9 6.2 6.5 6.8 8.3 9.8 10.5 11.2 41 3.7 3.9 4.1 4.3 4.5 4.7 4.9 6.9 8.9 9.9 10.9 43 - - - - - 2.8 2.9 5.4 7.9 9.2 10.5 46 - - - - - - - 4.0 7.0 8.6 10.1 10 Unitary Products Group 173858-YIM-A-0306 TABLE 8: D1EB048 SUPERHEAT CHARGING (IMPERIAL) OUTDOOR TEMPERATURE SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 1,800 CFM INDOOR WB TEMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 19.9 21.0 22.1 23.3 24.4 25.6 26.7 28.0 29.3 30.0 30.7 70 16.5 17.9 19.2 20.6 22.0 23.4 24.8 26.3 27.8 28.6 29.4 75 13.1 1 4.7 16.3 18.0 19.6 21.3 22.9 24.6 26.3 27.2 28.1 80 9.7 11.6 13.4 15.3 17.2 19.1 21.0 22.9 24.8 25.8 26.8 85 6.3 8.4 10.5 12.7 14.8 17.0 19.1 21.2 23.3 24.4 25.5 90 - 5.7 7.8 9.9 11.9 14.0 16.1 18.8 21.5 22.8 24.1 95 - - 5.0 7.0 9.1 11.1 13.1 16.3 19.6 21.2 22.8 1 00 - - - 5.4 6.9 8.5 10.0 13.6 17.3 19.1 20.9 1 05 - - - - - 5.9 6.9 11.0 15.0 17.0 19.0 110 - - - - - - - 8.3 12.6 14.8 17.0 115 - - - - - - - 5.6 10.3 12.7 15.1 TABLE 9: D1EB048 SUPERHEAT CHARGING (METRIC) OUTDOOR TEMPERATURE (°C) SUPERHEAT AT COMPRESSOR SUCTION (°C) AIRFLOW = 0.85 M3/S INDOOR WB TEMPERATURE (°C) 13 14 15 16 17 18 19 21 22 23 24 18 11.0 11.7 12.3 12.9 13.6 14.2 1 4.8 15.6 16.3 16.7 17.0 21 9.1 9.9 10.7 11.5 12.2 13.0 13.8 14.6 15.5 15.9 16.3 24 7.3 8.2 9.1 10.0 10.9 11.8 12.7 13.7 1 4.6 15.1 15.6 27 5.4 6.4 7.5 8.5 9.6 10.6 11.7 12.7 13.8 14.3 14.9 29 3.5 4.7 5.9 7.0 8.2 9.4 10.6 11.8 13.0 13.6 14.1 32 - 3.2 4.3 5.5 6.6 7.8 8.9 10.4 11.9 12.7 13.4 35 - - 2.8 3.9 5.0 6.2 7.3 9.1 10.9 11.8 12.7 38 - - - 3.0 3.9 4.7 5.6 7.6 9.6 10.6 11.6 41 - - - - - 3.3 3.9 6.1 8.3 9.4 10.5 43 - - - - - - - 4.6 7.0 8.2 9.5 46 - - - - - - - 3.1 5.7 7.1 8.4 Unitary Products Group 11 173858-YIM-A-0306 TABLE 10: D1EB060 SUPERHEAT CHARGING (IMPERIAL) OUTDOOR TEMPERATURE SUPERHEAT AT COMPRESSOR SUCTION (°F) AIRFLOW = 2,000 CFM INDOOR WB TEMPERATURE (°F) 55 57 59 61 63 65 67 69 71 73 75 65 21.9 23.8 25.7 27.6 29.4 31.3 33.2 34.2 35.1 35.6 36.1 70 16.0 18.4 20.7 23.0 25.3 27.6 30.0 31.3 32.7 33.4 34.0 75 10.1 12.9 15.7 18.4 21.2 23.9 26.7 28.5 30.2 31.1 32.0 80 - 7.5 10.7 13.9 17.1 20.3 23.5 25.6 27.8 28.9 29.9 85 - - 5.6 9.3 12.9 16.6 20.2 22.8 25.3 26.6 27.9 90 - - - 7.6 10.6 13.6 16.7 19.8 22.9 24.4 26.0 95 - - - 5.9 8.3 10.7 13.1 16.7 20.4 22.2 24.0 1 00 - - - - 6.4 8.2 10.1 13.2 16.3 17.9 19.5 1 05 - - - - - 5.8 7.0 9.6 12.3 13.6 1 4.9 110 - - - - - - - 6.1 8.2 9.3 10.4 115 - - - - - - - - - - 5.8 TABLE 11: D1EB060 SUPERHEAT CHARGING (METRIC) OUTDOOR TEMPERATURE (°C) SUPERHEAT AT COMPRESSOR SUCTION (°C) AIRFLOW = 0.94 M3/S INDOOR WB TEMPERATURE (°C) 13 14 15 16 17 18 19 21 22 23 24 18 12.2 13.2 14.3 15.3 16.4 17.4 18.4 19.0 19.5 19.8 20.0 21 8.9 10.2 11.5 12.8 14.1 15.4 16.6 17.4 18.2 18.5 18.9 24 5.6 7.2 8.7 10.2 11.8 13.3 14.8 15.8 16.8 17.3 17.8 27 - 4.1 5.9 7.7 9.5 11.3 13.0 14.2 15.4 16.0 16.6 29 - - 3.1 5.2 7.2 9.2 11.2 12.6 14.1 14.8 15.5 32 - - - 4.2 5.9 7.6 9.3 11.0 12.7 13.6 14.4 35 - - - 3.3 4.6 5.9 7.3 9.3 11.3 12.3 13.3 38 - - - - 3.6 4.6 5.6 7.3 9.1 9.9 10.8 41 - - - - - 3.2 3.9 5.4 6.8 7.6 8.3 43 - - - - - - - 3.4 4.6 5.2 5.8 46 - - - - - - - - - - 3.2 12 Unitary Products Group 173858-YIM-A-0306 HIGHVOLTAGECONN. 22 (7/8”) DIA. KNOCKOUT HIGH VOLTAGECONN. 50 (1-31/32”) DIA. KNOCKOUT FRONT COMPRESSOR SERVICE ACCESS COMPARTMENT PANEL LOW VOLTAGECONN. 22 (7/8”) DIA. KNOCKOUT SIDE SUPPLY AIR OPENING SIDE RETURN...
Dieses Handbuch ist für folgende Modelle:Splitgeräte - D1EB060 (443.45 kb)