Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Friedrich, modell 42

Hersteller: Friedrich
Dateigröße: 516.44 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Always refer to local and national codes. INSTALLATION - FINAL CHECKLIST • Is power to the unit ON? • Is ductwork sealed for an airtight • Is the thermostat level and fit? properly installed? • Are circuit breakers/power disconnect inside of the unit • Is the condensate drain line ! Is the heat anticipator indicator ON? installed and run to an set to the correct setting.? appropriate disposal site.? Test Run Test run in Heating, Cooling, and Emergency Heat mode as follows: a. Set fan control to ON. If fan runs, return control to AUTO setting. This verifies fan is working properly. b. Set system control from OFF to COOL. Lower temperature selector to 50°F or lower. The compressor should energize and cool air should flow from room registers. Once cooling test is complete, return system control to OFF setting. Wait 5 minutes. c. Set system control to HEAT and raise temperature selector to 80°F or higher. Compressor should energize, and warm air should flow from room registers. d. Set system control to EM HEAT (Emergency Heat). Compressor should turn off and warm air should continue to flow from the registers. (This step is for heat pumps only.) NOTE: During EM HEAT operation, temperature of air flowing from room registers may be slightly warmer than during normal HEAT mode operation. Leave both Installation Manual and Users Manual with owner or user of equipment. After 72 hours of operation, the unit will achieve full rated operating performance. Section IV . OWNER’S MANUAL AND OPERATING INFORMATION IDENTIFYING YOUR SYSTEM Take the time to familiarize yourself with the type of system you have. This knowledge will be of use in understanding the basic operation of your unit. A self-contained unit, like the Vert-I-Pak, has all of its major components in one cabinet located inside your home. The unit does not have a separate outdoor unit like a traditional “split-system” air conditioner or heat pump. Figure 4 shows the location of the major components inside the cabinet. The product model and rating data label is affixed to the unit front panel and provides the necessary information for specific identification of the unit. You should familiarize yourself with the model and serial numbers listed on the label. IMPORTANT FACTS To better protect your investment and to eliminate unnecessary service calls, familiarize yourself with the following facts: Your system should never be operated without a clean air filter properly installed. A dirty, clogged air filter will increase operating costs and shorten the life of the unit. The air filter should be replaced as it becomes dirty. Supply-air and return-air registers should not be blocked. Restricted airflow reduces the efficiency and life span of your unit. For your system to function properly, it MUST have a constant supply of outdoor air to the outdoor air coil located inside the unit. The outdoor-air intake and exhaust openings are located on the back side of the unit. Familiarize yourself with the outside air openings on the building and check to ensure that they are not obstructed. Thermostat Your multipurpose indoor thermostat is the control center for your comfort system. You should familiarize yourself with its proper operation. Attempting to control the system by other means – for instance, switching the electrical supply power ON and OFF – may cause damage to the unit. With some thermostats, increasing the HEAT mode temperature set point more than 2°F may cause the auxiliary electric heaters to operate to satisfy the call for heating. To minimize energy costs, do not increase the HEAT mode temperature set point by more than 2°F at a time. Depending on the design of your home and its ventilation ductwork and registers, areas of warm or cool air may develop throughout the home. Operating the unit with the fan switch “ON” increases air mixing throughout the home and reduces temperature variations within the home. Dehumidification During the cooling season, the Vert-I-Pak also dehumidifies the air in the home while is it cooling the air. After a few minutes of operation, water should run freely from the condensate drain line extended to the outside of your home. If condensate is not running from the drain line, check to be sure that the drain hose or pipe is properly connected to the drain fitting located on the bottom of the unit which is accessible from beneath the home. Check the drain line periodically during the cooling season to ensure the condensate is running freely from outside the home and draining away from the home’s foundation. (Note: in lower humidity climates, the indoor air may be too dry to generate condensate during the cooling mode.) Heat Pump If you are a first-time owner of an all-electric heat pump, the operating characteristics of the system may be different than you are accustomed to as compared to conventional electric resistance, gas or oil furnaces. Air ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 000 (516.44 kb)
Splitgeräte - 18 (516.44 kb)
Splitgeräte - 24 (516.44 kb)
Splitgeräte - 30 (516.44 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien