|
Anleitung Zusammenfassung
The operation and control status can be understood promptly. Display example [Operation mode] Dot liquid crystal display section Operation Control Function Limiting the set temperature range Auto Off timer Operation locking Air conditioning operation always within a limited temperature range Automatic turning off of air conditioning operation Preventing the random modification of setting Multi-language Display Multi- Ianguage 8 languages can be displayed. Display can be switched over for 8 kinds of language. [English] [Spanish] [Italian] [German] [French] [Russian] [Chinese] [Japanese] Weekly Timer The function of the weekly timer equipped can change the set temperature in addition to the ON/OFF control. Up to 8 patterns can be set for each calendar day. 4 Mr. SLIM New A/K Control System Configuration Mr. SLIM New A/K Control System Configuration Control function System configuration Features Necessary parts & equipment 1. Group control with 1 remote controller Remote Controller Indoor Unit Outdoor Unit Interface Interface ¦ Sequential start adaptable ¦ Same mode operation ¦ Maximum no. of units connectable per group: 16-refrigerant (Outdoor 16 sets) ¦ MAC-397IF-E (one for each outdoor unit) 2. Combined Remote/local control Distant Controller Panel Remote Controller Indoor Unit Relay Box Adapter ¦ Simultaneous ON/OFF remote ¦ Operation can be switched between the distant controller panel and handheld controller ¦ Timer adapter PAC-SE55RA-E (connect to CN32 on indoor circuit board) ¦ Relay box (on-site) 3. Operation with 2 remote controllers Remote Controller Indoor Unit ¦ 2 remote controllers can be connected to one group ¦ Control with the latest command ¦ Additional remote controller (option) 4. Individual control from distant room Remote Controller Indoor Unit (MAX. 500m) ¦ Extension of remote controller cord ¦ Remote controller cord (on-site) 5. Timer operation ¦ Weekly timer operation possible as standard (7 days-8 patterns) — ¦ Optional adapter allows operation with timer sold on the market ¦ Timer adapter PAC-SE55RA-E (connect to CN32 on indoor circuit board) 6. Operation by external signal ¦ Static signal receivable ¦ Timer adapter PAC-SE55RA-E (connect to CN32 on indoor circuit board) ¦ Pulse signal receivable ¦ Multiple remote controller adpter PAC-725AD (connect to CN51 on indoor circuit board) 7. Power failure automatic recovery Remote Controller Power Supply Indoor Unit ¦ Returns to the state before power failure as standard ¦ Function setting by remote controller 8. Connection of remote display Distant Display Remote Controller Adapter Indoor Unit Relay Box ¦ Connectable to display panel in the field adapter ¦ Multiple remote controller adpter PAC-725AD (connect to CN51 on indoor circuit board) ¦ Relay OMRON made LY-1 (DC12V) PAC-SE55RA-E MAC-397IF-E PAC-725AD Timer Adapter MA & Control Terminal Interface Multiple Remote Controller Adapter (10 units of PAC-SA88HA-E) 5 Twin Multi Operation Twin Multi Operation INDOOR UNIT INDOOR UNIT OUTDOOR UNIT Multi-Distribution Pipe Two indoor units can be connected to a single outdoor unit and all units can be operated simultaneously from a single remote controller using the optional multi-distribution pipe (only indoor units of the same capacity and type can be connected). Outdoor Uni...
Dieses Handbuch ist für folgende Modelle:Splitgeräte - Mr.Slim PCH-3GAK (659.14 kb)
Splitgeräte - Mr.Slim PEH-EAK (659.14 kb)
Splitgeräte - Mr.Slim PKH-3FAK (659.14 kb)
Splitgeräte - Mr.Slim PKH-FAK (659.14 kb)