Login:
Stimmen - 5, Durchschnittliche Bewertung: 3.4 ( )

Anleitung Mitsubishi Electronics, modell A18AR

Hersteller: Mitsubishi Electronics
Dateigröße: 334.72 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


B Each time this button is pressed, the set time increases by 1 hour to 12 hours. To release the timer: SELECT • Press the button until (OFF TIMER) and (ON TIMER) are not displayed. Note: The OFF TIMER and the ON TIMER cannot be set at the same time. 5 2.9. Emergency operation When the remote controller cannot be used When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the emergency buttons on the grille. ADEFROST/STAND BY lamp BOperation lamp CEmergency operation switch (heating) DEmergency operation switch (cooling) EReceiver Starting operation • To operate the cooling mode, press the button D. • To operate the heating mode, press the button C. Note: • Details of emergency mode are as shown below. Details of EMERGENCY MODE are as shown below. However, the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation. The fan speed is set to High in test run and shifts to Medium after 30 minutes. Operation mode COOL HEAT Set temperature 24°C 24°C Fan speed med. med. Airflow direction Horizontal 30° Downward 70° Stopping operation • To stop operation, press the button D or the button C. A B C D E A B D C 3. Care and cleaning Caution: • Always turn off the power, first on the remote controller and then the main switch, before cleaning or servicing the unit. • When installing or removing the filter or the intake grille, do not stand on an unsteady surface. You may fall and injure yourself. Be also careful not to let dust fall into your eyes. Dirty or clogged filters block the airflow and reduce efficiency. Very dirty filters can damage the air-conditioner itself. Intake grille removal 1Pull the catch on the intake grille in the direction indicated by the arrow and it should open. 2Unhook the hinges to remove the intake grille from the grille. Filter removal 1Open the intake grille. 2Release the catch on the center edge of the intake grille and pull the filter forward to remove the filter. A Catch B Grille C Intake grille D Filter 3.1. Cleaning the filters and the indoor unit Cleaning the filter • Clean the filter using a vacuum cleaner. If you do not have a vacuum cleaner, tap the filter against a solid object to knock off dirt and dust. • If the filter is especially dirty, wash it in lukewarm water. Take care to rinse off any detergent thoroughly and allow the filter to dry completely before putting it back into the unit. Caution: • Do not dry the filter in direct sunlight or by using a heat source, such as an electric heater: this may warp it. • Do not wash the filter in hot water (above 50°C), as this may warp them. • Make sure that the air filter is always installed. Operating the unit without air filter can cause malfunction. Cleaning the indoor unit • Wipe the outside of the unit with a clean, dry, soft cloth. • Clean off any oil stains or finger marks using a neutral household detergent (such as dishwashing liquid or laundry detergent). Caution: Never use gasoline, benzene, thinner, scouring powder or any type of non-neutral detergent, as these substances may damage the unit’s case. 2. Operation 4. Troubleshooting Before you call out a repair man, check the following table to see whether there is a simple solution to your problem. Problem Solution Problem Solution Unit does not cool or heat very well. Clean the filter. The operation lamp of the wireless remote controller’s receiver is flashing. A self-diagnostic function is being performed to preserve the air conditioner. * Do not attempt to make repairs yourself. Turn the main switch off and contact the dealer from whom you bought the air conditioner. Provide him or her with the name of the unit and the number of times the operation lamp of the wireless remote controller’s receiver flashes. The airflow direction suddenly changes. After one hour of cooling mode or drying mode operation with the airflow in a downward direction, the unit will automatically change to the “Horizontal airflow” mode. When the unit is in the heating or defrosting mode, it will automatically change to the “Horizontal airflow” mode. A white mist is expelled from the indoor unit. This may occur just after the unit is turned on when a high level of humidity is present in the room. Unit operates even if ON/OFF button has not been pressed. It occurs for the AUTO RESTART FUNCTION mode. Press the ON/OFF button to stop operation. The air conditioner cannot be operated for about 3 minutes when restarted. This protects the air conditioner according to instructions from the microprocessor. Please wait. No indication of wireless remote controller, indication is dim, or signal transmission cannot reach remote controller sensor. The batteries have run out. Replace the batteries with new ones (size AAA), and then press the reset button. Though both alkaline batteries and manganese batteries can be used, alkaline batteries are recommended because their service life is lo...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - A12 (334.72 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien