Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Kenmore, modell 78079

Hersteller: Kenmore
Dateigröße: 1.07 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


See Figure 30. Under normal conditions, unit can evaporate water as fast as it is removed from indoor air. In very humid conditions, however, excess water may drip off chassis, To avoid dripping, install condensate drain cup (included with unit). Insert condensate drain cup through %" hole recessed in flange on right side of outer case bottom. Then place ." diameter hose or tube on bottom spout of drain cup. Rgure 30. Condensate Drain Cup Installation 1. Outer case 2. Condensate drain cup 3. Y2"diameter hose 13. See Figure 30A. With additional help, slide chassis into outer case. Attach base pan retaining clip to chassis with ." screw. Reinstall front frame, air filter, and front grille. Because window sash helps keep unit in window, make sure sash contacts case before reinstalling chassis. 14. To be sure air conditioner installation is correct, review all steps and ensure all parts are securely fastened, as outlined in instructions. If final inspection shows installation is solid and complete, airconditioner can be operated safely. To begin operation, plug unit into electrical outlet. Figure 30A. Attaching Chassis To Outer Case 1. Frontframe 2. Base pan clip 3. Base pan handle 4. Chassis 2 Through-the-Wall Installation_12000, and 18000 Btu Units (Models 70129, and 78189) Kenmore Room Air Conditioners with slide-out chassis cases (models 70129, and 78189) are designed to be installed ina window or through a wall. Following are instructionsare for wall installation. NOTE: Kenmore Room Air Conditioner Models 78079 and 70089 (7000 and 9000 Btu) are designed for window installationonly. See instructions beginning on page 7. Typical Cabinet Dimensions Figure 31. Slide-Out Chassis Outer Case Dimensions 12000 Btu 18000 Btu 1. 9 inches 14. inches 2. 16. inches 19. inches 3. 233A inches 25318inches 4. 231/16inches 28. inches 3 Installation General Instructions See Figure 32. Dimensions of finished opening (required) in wall are: • 24." wide by 16_" high (12000 Btu model). • 19%" high by 257/8"wide (18000 Btu model) Lower left inside comer of opening must be within 6' of appropriate electrical outlet. For proper condensate drainage when installed, back of case should be %" lower than front of case. Inside edge of case must extend 3,4,beyond inside wall to properly seat air conditioner front cover. After installation, caulk completely around outside of unit to ensure proper seal. Depending upon wall construction and opening location, a lintel (not provided) may be required. I CAUTION I To reinstall chassis and reattach front cover, outer case must be square and level from side to side. Use wood shims between sides of case and finished opening_especially where case is secured to opening--to prevent warping or distorting case. Check installation with carpenters' square. To improve appearance, framing inside opening with decorative molding (not provided) may be desired. If molding is used, mount case in opening so inside edge of case extends _" beyond molding. When installing unit through thick walls (12000 Btu unit in walls thicker than 9"; t 8000 Btu unit in walls thicker than 14."), be sure air flows freely through side louvers on outer case. See Installation in Walls Exceeding Outer "_aseDimensions. Figure 32. Typical Wall Opening = 16sA inches 19_inches _ 12000 Btu 18000 Btu = 241/4inches 257/8inches 1. See Installation in Walls Exceeding Outer Case Dimensions. 2. Appropriate electrical outlet must be within 6' of this point. /J Brick Veneer or Frame Wall Construction See Figure 33. A framed, finished opening of proper dimensions should be cut out or built into wall. Frame opening with 2" x 4" lumber. Figure 33. Brick Veneer Wall Opening 1. 2" x 4" framing lumber 12000 Btu 18000 Btu A = 163,4inches 193Ainches B = 24. inches 25718inches A To install outer case in opening: 1. See Step I under Window Installation--12000, and 18000 Btu Units to remove air conditionerchassis from outer case. 2. See Figure 34. Place outer case in wall opening. Adjust case so front extends into room 3A"and case has a %" back slope (lay carpenters' level inside case and adjust case to . bubble on level). NOTE: If air conditioner will be framed by decorative molding, extend case into room 3A"beyond molding. 3. Pre-drill holes in each side of case at approximate locations shown in Figure 34. Use wood shims to fill gaps between case and finished opening, especially where case will be secured to wall. DO NOT WARP or distort case when installing shims. When pmpedy positioned, secure case in opening with four #10 x 1" (25mm) wood screws (not provided). 4. Caulk all four sides of case to seal case in place. Installation Figure 34. Secudng Outer Case inWall Opening 1. Linteland flashing (if required) 2. Provide %" slope to outside for condensate drainage 3. Attach outer case to framing intwo places on each side of case 4. Completely caulk or seal all four sides of outer case 5. Outer case extends into room _" i % % 5 Masonry Construction See Figure...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 70089 (1.07 mb)
Splitgeräte - 70129 (1.07 mb)
Splitgeräte - 78189 (1.07 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien