Anleitung Panasonic, modell HQ2052UH

Hersteller: Panasonic
Dateigröße: 1.66 mb
Dateiname: HQ2052UH.PDF
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


10. b. While steadying the air conditioner, carefully bring the window sash down behind the upper guide of the air conditioner, as shown in Fig. 11. TYPE A TYPE AFig. 6 SEAL STRIP (TYPE D) Fig. 7 ROOM SIDE CENTER LINE INNER SILL INNER SILL Fig. 8 CENTER LINE Fig. 10 OUTSIDE INSIDE L BRACKET OUTER SILL TYPE A 8" 8" CENTER LINE Fig. 9 SEAL WINDOW FRAME BOTTOM GUIDE ABOUT 1/4" L BRACKET UPPER GUIDE Fig. 11 10 4. SECURE THE GUIDE PANELS Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Fig. 12. 5. INSTALL THE SASH SEAL AND SASH LOCK a. Cut the sash seal (TYPE E) to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room, as shown in Fig. 12. b. Fasten the L bracket using a screw (TYPE A), as showninFig.12. 6. a. Remove the screws that secure the cabinet and base pan in the right side. b. Fasten the support bracket (TYPE G) using a removed screw. Attach the support bracket (TYPE G) in the inner window sill with a screw (TYPE B), as shown Fig. 13. 7. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. C. HOW TO SECURE THE DRAIN PIPE In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. (Fig. 14) Press the drain pipe into the hole by pushing down and away from the fins to avoid injury. REMOVAL FROM WINDOW L BRACKET TYPE B SASH SEAL (TYPE E) TYPE A DRAIN PIPE DRAIN CAP TYPE B Support Bracket (TYPE G) Fig. 12 Fig. 13 Hang Push Fig. 14 Turn the air conditioner off, disconnect the power cord, remove the Support Bracket, L bracket and the screws installed through the top and bottom of the guide panels, and save for reinstallation later. Close the guide panels. Keeping a firm grip on the air conditioner, raise the sash, and carefully tilt the air conditioner backward, draining any condensate. Lift the air conditioner from the window and remove the sash seal from between the windows. Electrical Data Features and Installation Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut or remove the grounding prong from the plug. Power supply cord with 3-prong grounding plug Standard 125V, 3-wire grounding receptacle rated 15A, 125V AC Use 15 AMP, time delay fuse or circuit breaker. USE OF EXTENSION CORDS Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V. 11 Before you call for service... Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the relay click when the compressor cycles on and off. • Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit. • The fan may run even when the compressor does not. Abnormal Operation Problem Possible Causes What To Do Air conditioner does not start The air conditioner is unplugged. Thefuseisblown/circuit breaker is tripped. Power failure. • Make sure the air conditioner plug is pushed completely into the outlet. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. • When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. Air conditioner does not cool as it should Airflow is restricted. TEMP Control set to a higher number. The air filter is dirty. The room may have been hot. Cold air is escaping. Cooling coils have iced up. • Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner. • Set the TEMP Control to a lower number. • Clean the filter at least every 2 weeks. See the operating instructions section. • When the air conditioner is first turned on youneedtoallowtimefor theroomtocooldown. • Check for open furnace floor registers and cold air returns. • Set the air conditioner's vent to the closed position. • See Air Conditioner Freezing Up below. Air conditioner freezing up Ice blocks the air flow and stops the air conditioner from cooling the room. • Set the mode control at High Fan or High Cool with thehightemperature. Before you call for service... 12 Memo 13 Instrucciones de FuncionamientoRequerimientos de la VentanaAntes de avisar al Servicio TecnicoPrecauciones Importantes de seguridadInstrucciones de FuncionamientoRequerimientos de la VentanaAntes de avisar al Servicio TecnicoPrecauciones Importantes de seguridad PARA SU INFORMACION Escriba aqui los numeros...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien