Login:
Stimmen - 3, Durchschnittliche Bewertung: 3 ( )

Anleitung Panasonic, modell CWXC55HU

Hersteller: Panasonic
Dateigröße: 2.16 mb
Dateiname: CWXC55HU.PDF
Unterrichtssprache:eneset
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The upper and lower sash must open sufficiently to allow a clear vertical opening of 13" from the bottom of the sash to the window stool. 2.If a storm window presents interference, fasten a 2" wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. See Fig. 5-2. The top of the wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside. 3. Install a second wood strip (approximately 18" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown in Fig. 5-2. 4. The thickness of the second wood strip may not be the same as the first wood strip. The thickness of the second wood strip must be defined to keep the 3/4 inch distance between the inner sill or the top of the first wood strip and the outer sill. INNER WOOD STRIP MOUNTED 1" SILL ON TOP OF INNER SILL STORM WINDOW INNER FRAME SILL WOOD STRIP FOR L BRACKET OUTER OUTER SILL SILL INDOORS OUTDOORS INDOORS OUTDOORS 3/4" CLEARANCE Fig. 5-1 Fig. 5-2 Installation HARDWARE TYPE A: Qty:11 (SHORT SCREW) TYPE B: Qty:5 (WOOD SCREW) TYPE C: Qty:3 (L BRACKET) DRAIN PIPE Qty:1 25/64"(10mm)5/8"(16mm) TYPE D: Qty:1 (SEAL STRIP) TYPE E: Qty:1 (SASH SEAL) TYPE F: Qty:2 (GUIDE PANEL) TYPE G: Qty:1 (SUPPORT BRACKET) (Adhesive backed) (Not adhesive backed) Features and Installation 9 Features and Installation Features and Installation A. BEFORE INSTALLATION 1. Insert the guide panels into the guides of the air conditioner. Fasten the curtains to the unit with screws (TYPE A), as shown Fig. 6. 2. Cut the adhesive-backed seal strip (TYPE D) to the window width. Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window. (Fig. 7) B. NOW START INSTALLATION 1. LOCATING UNIT IN A WINDOW Open the window and mark center line on the center of the inner sill, as shown in Fig. 8. 2. ATTACH L BRACKET a. Install the L brackets behind the inner window sill, with short side of bracket as shown. Use the 2 screws (TYPE A) provided. b. The bracket helps to hold the unit securely in place. Be sure to place bracket edge flush against back of inner sill. See Fig. 9. During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from window. CAUTION 3. INSTALL THE AIR CONDITIONER IN THE WINDOW a. Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the L bracket. See Fig. 9. IMPORTANT : When the air conditioner drops into the L bracket, the air conditioner will be centered in window opening as shown in Fig. 10. b. While steadying the air conditioner, carefully bring the window sash down behind the upper guide of the air conditioner, as shown in Fig. 11. TYPE A TYPE AFig. 6 SEAL STRIP (TYPE D) Fig. 7 ROOM SIDE CENTER LINE INNER SILL CENTER LINE OUTSIDE INSIDE L BRACKET OUTER SILL INNER SILL TYPE A 8" 8" CENTER LINE Fig. 8 Fig. 9 Fig. 10 SEAL WINDOW FRAME BOTTOM GUIDE ABOUT 1/4" L BRACKET UPPER GUIDE Fig. 11 10 4. SECURE THE GUIDE PANELS L BRACKET TYPE B SASH SEAL (TYPE E) TYPE A DRAIN PIPE DRAIN CAP TYPE B Support Bracket (TYPE G) Fig. 12 Fig. 13 Fig. 14 Hang Push Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Fig. 12. 5. INSTALL THE SASH SEAL AND SASH LOCK a. Cut the sash seal (TYPE E) to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room, as shown in Fig. 12. b. Fasten the L bracket using a screw (TYPE A), as shown in Fig. 12. 6. a. Remove the screws that secure the cabinet and base pan in the right side. b. Fasten the support bracket (TYPE G) using a removed screw. Attach the support bracket (TYPE G) in the inner window sill with a screw (TYPE B), as shown Fig. 13. 7. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electrical outlet. C. HOW TO SECURE THE DRAIN PIPE In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. (Fig. 14) Press the drain pipe into the hole by pushing down and away from the fins to avoid injury. REMOVAL FROM WINDOW Turn the air conditioner off, disconnect the power cord, remove the Support Bracket, L bracket and the screws installed through the top and bottom of the guide panels, and save for reinstallation later. Close the guide panels. Keeping a firm grip on the air conditioner, raise the sash, and carefully tilt the air cond...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien