Anleitung York, modell CHAMPION PLUS DNP048

Hersteller: York
Dateigröße: 896.82 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


UNIT FACTORY WIRED FOR 230 VOLT OPERATION. FOR 208 VOLT OPERATION 208 208V R/RED /BLKHEAT MOTORID FAN 54321S5 S4ID MOTOR CONTROLLER YELY1/ /BLUCOOL BRNC2/ WHTW1/ BRNC1/ 1514131211109 87654321 16 MOTOR "SPEED" CONNECTIONSTB2 TERMINAL BLOCK, 24V, ID BATB2 ID MOTOR CONTROLLER S5/P5 SOCKET/PLUG CONNECTION, 230V, 5 PIN ON ID MOTOR CONTROL * BLACK SQUARE INDICATES SWITCH POSITION SETTINGFACTORY 180 SEC120 SEC 90 SEC60 SEC INDOOR BLOWER HEAT OFF DELAY: (SEE RIGHT)*INDOOR BLOWER HEAT ON DELAY: 30 SECINDOOR BLOWER COOL OFF DELAY: 30 SEC INDOOR BLOWER COOL ON DELAY: 3 SEC CONTROL BOARD SETTINGS:COMBUSTION BLOWER POSTPURGE: 5 SEC S4/P4 SOCKET/PLUG CONNECTION, 24V, 16 PIN ON ID MOTOR CONTROLS3/P3 SOCKET/PLUG CONNECTION, 24V, 4 PIN ON GAS VALVES2/P2 SOCKET/PLUG CONNECTION, 24V, 4 PIN ON GAS VALVECN1/P1 SOCKET/PLUG CONNECTION, 24V, 6 PIN ON CONTROL BOARDBATB2 FOR COOLING AIRFLOWBLOWER CONNECTIONSTABLE 1"SPEED" CONNECTIONSFOR COOLING BLOWERSEE TABLE 1 BLKPRP 543 240V/BLK240V/PRP GRN ROOM THERMOSTAT 24V CONNECTIONSTB1 ON CONTROL BOARDFIELD WIRINGOPTIONAL WIRING AND DEVICESFACTORY WIRING AND DEVICES OUTDOORFANMOTORBLK BRN PRP 230-1-60MOTORDRAFT1 230-1-601MOTORID FAN L2L1 T2T1 M2-2M2-1 M2 ON CONTROL BOARD, 24-1-60, 18VA MAXEAC ELECTRONIC AIR CLEANER RELAY OUTPUTBOARD, 24-1-60, 18VA MAXHUM HUMIDIFIER RELAY OUTPUT ON CONTROL NNEACHUM NNEACHUM GRN VALVEGAS P3 4321 P2 1342 230-1-60230-3-60 GAS VALVE207/Y211/PR210/BL209/BK CLEARBLUBLU S34321 S24321 AFTER SERVICING.CLEARLY RENUMBERED FOR IDENTIFICATION. VERIFY PROPER OPERATIONIT MUST BE REPLACED WITH TYPE 105 DEGREE C, 600V WIRE OR EQUIVALENTIF ANY OF THE WIRE AS SUPPLIED WITH THIS UNIT MUST BE REMOVED,CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. 2. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING 220/O221/BR 110/BK240V/BLK110/BK100/BK BA T2T1 L2L1 M2 110/BK M2 CONTACTOR, DRAFT INDUCER MOTOR 107/PR100/BK 108/PR 203/BR(SEE NOTE 5)202/Y 107/PR108/PR 100/BK107/PR 201/BR200/R BRNPRP105/BL 212/R200/R 121/BKBK123/BL105/BL126/Y 211/PR208/PR206/R205/R204/O213/R CLEARBLUBLUBLK PRP 126/Y 123/BL121/BK 206/R210/BL209/BK 208/PR 207/Y 204/O 212/R201/BRC1/BRN214/BR221/BR220/O213/R W1/WHTY1/YEL 203/BR202/Y HEATCOOL HSP GAS HEAT SECTION PSLSRS MOTORDRAFT L3 L2L1 CONTROL BOX T1 CONTROL BOARD CB 12 S DILEADSMOTORUNUSED4321CXXFMR CN16 5 4 3 2 1 OFF DELAY TB1YCRWYGC SEC C230 RC2LUGGND T3T2T1 L3L2L1 BA M1 LUGGND NOTES:4. SEE UNIT NAMEPLATE FOR MAXIMUM FUSE SIZE AND MINIMUM CIRCUIT AMPACITY. 3. MOTORS ARE INHERENTLY PROTECTED.CODES IN EFFECT AT TIME OF INSTALLATION OF THIS UNIT. 1. ALL FIELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY, LOCAL AND/OR NATIONAL3.2 AMP LEGEND: M1 CONTACTOR, COMPR & OD FAN T1 TRANSFORMER, 24V, 75 VARC2 OUTDOOR FAN RUN CAPACITOR CB CIRCUIT BREAKERCOMPR COMPRESSOR HSP HOT SURFACE TO PILOT LS LIMIT SWITCH.193 IWC NOM (.33 IWC MAX) PS PRESSURE SWITCH - MAKES @ RS ROLLOUT SWITCHIDENTIFIED TERMINAL ON CAPACITOR 035-18845D000 REV.CBEFORE SERVICING THIS UNITCAUTION - OPEN ALL DISCONNECTSLKJHGFEDCBA CONNECTION DIAGRAM ELEMENTARY DIAGRAMCOOLING UNIT WITH GAS HEAT RC2 202/Y203/BR 208/230-3-60POWER SUPPLY 126/Y123/BL121/BK L3 L2 L1 COMPR3 105/BL PRPBRNBLK T3T2T1 L3L2L1 M1-3M1-2M1-1 1MOTOROD FAN 230V PRI T1C CB 75 VASEC 24V 200/R 201/BR212/R BLUBLU HSP S3S2 211/PRPS 207/Y208/PR209/BK210/BL206/R 204/O RS BOARDCONTROL YC 12S DILEADSMOTORUNUSED NEUTRAL 4321XFMRXC HEATCOOLP1CN1 653214 ALS 205/R213/R ALS AUXILARY LIMIT SWITCH LS 213/R ALS 205/R M1 FSHP LP ASCT 3 1 2 7 2 802/BK 803/BK 804/BK 807/BL 800/YLR 801/BL (SEE NOTE 5) (SEE NOTE 5)805/BL BLRA 806/BR(OPTIONAL ACCESSORIES - SEE NOTE 5) ACCESSORY) OPENS @ 380 PSIGHP HIGH PRESSURE SWITCH (OPTIONALOPEN @ 26 DEGREE FFS FREEZESTAT SWITCH (OPTIONAL ACCESSORY)OPEN @ 7 PSIGLP LOW PRESSURE SWITCH (OPTIONAL ACCESSORY) LR LOCK OUT RELAY (OPTIONAL ACCESSORY)(OPTIONAL ACCESSORY) ASCT ANTI-SHORT CYCLE TIMER PRESENT, WIRE 202/Y IS CONNECTED TO M1 COIL.ONLY IS PRESENT WIRE 202/Y IS CONNECTED TO ASCT-3. IF NEITHER LR OR ASCT AREIF LR ONLY IS PRESENT, WIRE 801/BL AND 805/BL ARE CONNECTED TO M1 COIL. IF ASCT5. IF BOTH LR AND ASCT ARE PRESENT, WIRE 801/BL AND 805/BL ARE CONNECTED TO ASCT-3. COMPR 2A 7B 800/Y801/BL (SEE NOTE 5)LR 802/BK800/Y202/Y FS 803/BK804/BK LP 805/BL804/BK HP 803/BK802/BK 321807/BL(SEE NOTE 5)ASCT 801/BL805/BL806/BR 100/BK 107/PR 201/BR OFF ON DELAY 13121110987654321 THERMOSTATROOMR G Y W HEATCOOLOFFONAUTO TB1CGYWR W1/WHTR/REDY1/YELC1/BRNC2/BRNCOOL/BLUHEAT/BLK 316122P4/S4115 COOL/BLU TO:WIRECONNECT (CFM)AIRFLOWFOR COOLING1400 (ARI RATING) TB2-A 1350 TB2-B 1200 (ARI RATING) TB2-A 1600 TB2-B UNIT SIZE-036-036-048-048 1250 TB2-B 1000 (ARI RATING) TB2-A-030-030 1500 TB2-B 1350 (ARI RATING) TB2-A-042-042 --- --- --- --- 1212160270 ALSRS 0364 TUBE LS 160 1306 9--- --- --- --- 1212160270 ALSRSLS 160 1306 9--- --- --- --- 1212160200 ALSRS 0362 TUBE LS 140 1106 9+/- CLOSE+/- OPENCONTROL SETPOINT (DEG F) UNIT SIZE DEVICETEMPERATURE CONTROLS --- --- --- --- 1212160270 ALSRS 0485 TUBE LS 160 1306 9--- --- --- --- 121...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - CHAMPION PLUS DNP024 (896.82 kb)
Splitgeräte - CHAMPION PLUS DNP030 (896.82 kb)
Splitgeräte - CHAMPION PLUS DNP036 (896.82 kb)
Splitgeräte - CHAMPION PLUS DNP042 (896.82 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien