Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Broan, modell ERV90HCT

Hersteller: Broan
Dateigröße: 4.29 mb
Dateiname:
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Check if all wires are correctly inserted in their corresponding holes in the terminal block. (A wire is correctly inserted when its orange receptacle is lower than another one without wire. On picture beside, wire A is correctly inserted, but not wire B.) A B VE0106 - 17 4. CONTROLS (CONT’D) 4.2 ELECTRICAL CONNECTION TO OPTIONAL WALL CONTROLS (CONT’D) 4.2.1 ELECTRICAL CONNECTION TO VT4W MAIN WALL CONTROL NO C NC I OC OL Y R G B BGOCG BY VE0100A MAIN WALL CONTROL VT4W REAR VIEW 4.2.2 ELECTRICAL CONNECTION TO OPTIONAL AUXILIARY WALL CONTROLS NOTE: If an optional auxiliary wall control is activated and then, the Humidity Control is being activated, the Humidity Control will override the auxiliary wall control commands. NO C NC I OC OL Y R G B 20-MINUTED LIGHTED PUSH BUTTON (5 MAXIMUM) 60-MINUTE CRANK TIMER HUMIDITY CONTROL VE0110A COMFOTZONEOFF%RELATIVEHUMIDITY70% 60% 50%40% 30% 25% 20% HUMIDITYCONTROL Once the wall control(s) connections have been made, insert the terminal connector in the bottom of the unit, on the electrical compartment front face. WARNING Risk of electric shock. Before performingany maintenance or servicing, alwaysdisconnect the unit from its power source. AVERTISSEMENT Danger d’electrocution. Debranchez toujours l’appareil avant d’entreprendre des travaux d’entretien ou de reparation. CAUTION Unscrew both screws to open the electrical compartment. To completely remove, detach from its retention wire inside. ATTENTION Devisser les deux vis pour ouvrir le compartiment electrique. Pour retirer completement, le detacher de son fil de retention interieur. No light OFF or remote controled Amber light LOW speed Green ligh HIGH speed Blinking light See User Manual Sans lumiere Arrete ou controle par controle mural Lumiere ambre Basse vitesse Lumiere verte Haute vitesse Clignotant Voir guide d’utilisation VD0182 TERMINAL CONNECTOR 4.3 VT4W OPTIONAL MAIN WALL CONTROL OPERATION COLOR MODE SUGGESTED USE GREEN INTERMITTENT SELECT THIS MODE WHEN YOU ARE AWAY FROM THE HOUSE FOR A FEW DAYS. ALSO, WHEN YOU DEEM THE INSIDE AIR IS TOO DRY IN HEATING SEASON, OR TOO HUMID DURING COOLING SEASON. IN THIS MODE, THE UNIT IS OFF FOR 40 MINUTES PER HOUR AND VENTILATES AT MINIMUM SPEED THE REMAINING 20 MINUTES OF THE HOUR. YELLOW MIN SPEED VENTILATION FOR NORMAL DAILY OPERATION. RED MAX SPEED VENTILATION FOR EXCESS POLLUTANTS AND HUMIDITY (PARTIES, ODORS, SMOKE, ETC.). INTERMITTENT MAX MIN VT4W VC0070 - 18 4. CONTROLS (CONT’D) 4.4 OPTIONAL AUXILIARY WALL CONTROLS OPERATION 4.4.1 20-MINUTE LIGHTED PUSH-BUTTON TIMER Set the push-button timer to ON. The fan motors will then operate at high speed for 20 minutes and the indicator will light up. To stop activation, push one time; the unit will then get back to previous selection. 4.4.2 60-MINUTE CRANK TIMER ON VC0084 OFF102030405060TURNPAST20 This control makes the system operate at high speed for periods varying from 10 to 60 minutes. VC0017 4.4.3 HUMIDITY CONTROL Setting during the fall, winter and spring months: Adjust knob to the desired maximum humidity level. Setting during summer: Adjust knob to the OFF positon. CAUTION Do not select a humidity level below 30%. This could lead to excessive dryness in the air causing discomfort for the occupants. COMFORTZONEOFF%RELATIVEHUMIDITY70% 60% 50%40% 30% 25% 20% HUMIDITY CONTROL VC0085 5. ELECTRICAL CONNECTION TO THE FURNACE WARNING Never connect a 120-volt AC circuit to the terminals of the furnace interlock (standard wiring). Only use the low voltage class 2 circuit of the furnace blower control. 0 ! For a furnace connected to a cooling system: On some older thermostats, energizing the “R” and “G” terminals at the furnace has the effect of energizing “Y” at the thermostat and thereby turning on the cooling system. If you identify this type of thermostat, you must use the alternate furnace interlock wiring. Standard furnace interlock wiring Alternate furnace interlock wiring W R G Y W R G C Y UNIT TERMINAL CONNECTOR THERMOSTAT TERMINALSFOUR WIRESTWO WIRESheating only FURNACE 24-VOLT TERMINAL BLOCK NO C NC I OC OL Y R G B W R G Y W R G Y C THERMO wiring 4 WIRES2 WIRESheating only nu UNIT TERMINAL CONNECTOR NO C NC I OC OL Y R G B FURNACE 24-VOLT TERMINAL BLOCK 2 WIRES TWO WIRES VE0108A - 19 COOLING SYSTEM COOLING SYSTEM WIRING DIAGRAM Field wiringremote control( see notes3 & 4) 120 V, 60 Hz W1 J5J7J6J4 ELECTRONICASSEMBLY 12312121231234 1 2 1 2 3 4 5 J9 J11 J10 12 J12 J13J1410987654321 B 24 Vclass 2 9.5 Vclass 2 Line voltage factory wiring Class 2 low voltage factory wiring Class 2 low voltage field wiring See note 1 120 V90 V68 V neutral Door interlock switch (magnetically actuated Exhaust fan motor 12345 12 1 2 J3J2 J1 t° Damper motorBK Furnace blower interlockJ14-1 : NOJ14-2 : COMJ14- 3 : nc (optional; see notes3, 5) DAMPERELECTRONIC ASSEMBLY Defrosttemperature sensor ICP BK YRG FAN MOTORSSPEED SELECTION SETTING FAN SPEEDSFactory shipped Low - High Low-Med select Low- Med JU1 123JU1 123W W BKWBLR G BK BL BNBN BKBKBKBKBK B...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - HRV90HT (4.29 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien