Anleitung Freecom Technologies, modell RCS-M2000U

Hersteller: Freecom Technologies
Dateigröße: 94.47 kb
Dateiname: a446e265-f491-451f-bbe5-4b62c52172a6.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Place unit in its upright position for a minimum of three hours before operating for the first time. 1. 2. 3. 4. Place unit on a solid, level surface. Operating this unit on uneven or soft surfaces may cause vibration, noise, and possible water leakage from the condensate tank. Place unit at least 20" from any walls, draperies, or other obstructions. Carefully push the unit on its caster wheels to desired location. CAUTION: Do not operate unit without condensate water tank and air filters properly in place. Check that condensate water tank is properly installed. When properly installed, the door of the condensate water tank will be flush with the exterior of the unit. Check that air filter is clean and properly installed. OPERATION CAUTION: To avoid damage and voiding your warranty, place unit in its upright position for a minimum of two hours before operating. DO NOT operate unit without condensate water tank and air filter properly in place. Cooling This unit is intended to cool a 200-400 square foot area. The unit’s cooling capacity will vary according to room temperature and humidity. Consult your Freecom dealer for specific application and suitability. 1. Plug power cord into a standard household outlet. Use this product only with the proper electrical voltage. See “SPECIFICATIONS” on previous page. WARNING: Do not plug this appliance into an outlet that is being used by other appliances or electrical devices. When installing the electrical plug into the outlet, never touch or bend the metal prongs and always push plug into outlet by using the molded plug. Never use the electrical plug to start or stop the unit and avoid pulling, folding, or stretching the electrical cord. 2. Press “POWER ON/OFF” button on control panel. The unit will power up and air will begin blowing from the front louvers. NOTE: This unit is equipped with a special safety time delay feature. The compressor (cooling mechanism) may be delayed for up to five minutes. This safety feature prevents damage to the compressor. The "COMP. ON" light will turn on while the compressor is running. 3. Press “MODE” button on control panel to choose "FAN," "HI," "ME," or "LO." The FAN setting is for air circulation only and does not provide any cooling. To change from a cooling mode to fan mode, press "POWER ON/OFF" button to turn unit off. Press "POWER ON/OFF" button again and immediately press "MODE" button to FAN setting. 4. Press either "THERMO CONTROL" button to control a colder or cooler setting. The default temperature is 75.F. Press left button (COLD) to desired colder setting; right button (COOL) to desired cooler setting. Each press of the button will adjust the temperature approximately 3.5.F. CAUTION: To avoid injury or damage and voiding the warranty, DO NOT manually adjust the vertical louvers. 5. Adjust horizontal louvers (up or down) as desired by moving the louver handles up or down. The top louver handle controls the top half of the horizontal louvers; the lower louver handle controls the bottom half of the horizontal louvers. DO NOT adjust horizontal louvers while vertical louvers are operating. OPERATION (contd.) 6. Press “AUTO SWING” button on control panel to begin oscillating vertical louvers. The vertical louvers will move slowly from left to right and back again for optimum air distribution. Press button again to maintain a desired “fixed” position to distribute more cooling air to one side of the room. DO NOT adjust vertical louvers manually. 7. If desired, press “TIMER-SET” button on control panel to program the air conditioning unit to turn off in 1, 2, 3, 4, 5, 6, 7, 8, or 9 hours. To cancel timer setting, press "TIMER-RESET" button. ACCESSORY INSTALLATION Exhaust Duct Kit The Exhaust Duct Kit is an accessory which, when used with the RCS-M2000 series air conditioning units, will increase cooling efficiency by directing warm air exhaust out of the room. The Exhaust Duct Kit can be used with other Freecom accessories, such as the Window Panel Vent Kit (included), Sliding Door Vent Kit, Ceiling Vent Kit, or Through-the- Wall Kit for maximum cooling efficiency. WARNING: The Freecom Exhaust Duct Kit has been specially designed for use with the RCS-M2000 series air conditioning units. Using other duct materials, components, or extensions will decrease cooling efficiency or cause damage to the product, and void your warranty. 1. Press “POWER ON/OFF” button to stop unit if it is operating. Unplug power cord from outlet. 2. Slide square end of bent exhaust duct kit over exhaust on rear of unit. Push nozzle onto round connector end of vent duct pipe. 3. Install outlet nozzle in an open window, through a wall or false ceiling. ACCESSORY INSTALLATION Window Panel Kit (Optional Accessory) The Window Panel Kit is an accessory which, when used with the Exhaust Duct Kit, will increase cooling efficiency by directing warm air exhaust out a window and preventing outside air from getting into the room. 1. Extend panels to fit in window o...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - RCS-M2000T (94.47 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien