Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Carrier, modell 38APD025-130

Hersteller: Carrier
Dateigröße: 2.33 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


**Field supplied. See base unti installation instructions for refrigerant specialties part numbers. NOTES: 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System Design Manual for details. 2. All wiring must comply with the applicable local and national codes. 3. Wiring and piping shown are general points-of-connection guides only and are not intended for, or to include all details for, a specific installation. 4. Install field-supplied disconnect switch in accordance with all local and national electrical codes. 5. Liquid line solenoid valves (solenoid drop control) are not required but are recommended to prevent refrigerant migration to the compressor. 6. Factory-supplied accumulator not shown. 7. Dual-circuit piping shown. Single-circuit piping is similar but would only have one suction line and one liquid line. 8. A field-supplied (min. 5% up to 15%) bleed port TXV is required for every application. 9. Sight glass, LLSV, and filter drier are field supplied. 10. Long line length check valves are required for liquid line installation on all linear line length applications of more than 100 ft (30.5 m). For any 025-030 size dual-circuit unit application where evaporator is located higher than the condensing unit, check valves are required for linear line length above 55 ft (16.8 m). Fig. 2 — Accessory Location — 38AP Unit Rooftop Installation 3 a38-7099_gsNOTES: LEGENDa38-7099_gsNOTES: LEGEND LLSV — Liquid Line Solenoid Valve NEC — National Electrical Code TXV — Thermostatic Expansion Valve Piping *Field supplied. †Field supplied. See base unit installation instructions for refrigerant specialties part numbers. 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier SystemDesign Manual for details. 2. All wiring must comply with the applicable local and national codes. 3. Wiring and piping shown are general points-of-connection guides only and are notintended for, or to include all details for, a specific installation. 4. Install field-supplied disconnect switch in accordance with all local and national electricalcodes. 5. Liquid line solenoid valves (solenoid drop control) are not required but are recommended to prevent refrigerant migration to the compressor. 6. Factory-supplied accumulator not shown. 7. Dual-circuit piping shown. Single-circuit piping is similar but would only have one suctionline and one liquid line. 8. A field-supplied (min. 5% up to 15%) bleed port TXV is required for every application. 9. Sight glass, LLSV, and filter drier are field supplied. 10.Long line length check valves are required for liquid line installation on all linear linelength applications of more than 100 ft (30.5 m). For any 025-030 size dual-circuit unit application where evaporator is located higher than the condensing unit, check valvesare required for linear line length above 55 ft (16.8 m). Fig. 3 — Accessory Location — 38AP Unit Ground Level Installation Copyright 2010 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53380009-01 Printed in U.S.A. Form 38AP-5SI Pg 4 5-10 Replaces: New ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - 38APS025-065 (2.33 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien