Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Danby, modell DPAC10010

Hersteller: Danby
Dateigröße: 213.23 kb
Dateiname: 4fec99e0-9233-4b13-8c43-8e7d4dbf2e2e.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


NOTE: The time is adjustable between 1-24 hours. TEMPERATURE Adjust: • Used for adjusting the thermostat. • The default display is room temperature. • In cooling mode, when button is pressed, the set temperature is displayed and may be adjusted. After 15 seconds the display will revert back to room temperature. Temperature is only adjustable in cool mode. NOTE: By pressing both buttons at the same time for more than 3 seconds, the display will toggle between Celsius and Fahrenheit. Warning Light Condensed water may accumulate in the unit. If theinternal tank becomes full, the Warning signal in theLCD Display will light up and the unit will not operate until it has been drained. LCD Display Cooling Mode Dehumidify Mode Fan Only Mode High Fan Speed Medium Fan Speed Low Fan Speed Display Set Temperature Display Timer Setting of Auto Switch ON / OFF Warning Light (the machine will stop running) 5 OPERATION (cont’d) AIR CONDITIONING NOTE: The exhaust hose must be properly vented outdoors during airconditioning mode. 1) Press the POWER SWITCH key (Fig. A) to switch on the unit, and the previous set temperature will be shown in the temperature display area of thecontrol panel. 2) Press the MODE key (Fig. B) until the COOL indicator light illuminates on thecontrol panel (Fig.C). Each depression of the MODE key will advance to adifferent mode setting (Cool- Dehumidifier-Fan) 3) Press the appropriate increase or decrease buttons (Fig. D1 & D2) toselect a suitable operating temperature setting. Temperature settings areadjustable between 16°C (61°F) to 32°C (89°F). 4) Press the FAN key (Fig. E) to select the desired fan speed setting (Auto-High- Med.-Low). Your selection will appear on the control panel (each depression ofthe fan key will advance to a different setting). • Cooling stops automatically when the set temperature is achieved. Coolingresumes when the room temp. rises above the “set” temperature level. DEHUMIDIFIER: NOTE: The exhaust hose does NOT have to be vented outdoors during dehumidifier mode. 1) Press the ON/OFF key pad to switch the unit on (Fig. A) 2) Press the MODE key (Fig. B) until the DRY indicator illuminates on the control panel (Fig. G).Each press of the MODE key will advance to a differentmode setting (Cool-Dehumidifier-Fan). 3) If room temperature is 25°C (77°F), fan speed can be adjusted. Press the Fankey (Fig. E) to select the desired FAN SPEED setting. Your selection willappear on the contol panel. Each depression of the fan key will advance to adifferent fan speed (High- Med.- Low) as shown in Fig. F. Otherwise, fanspeed is fixed to “low”. Note: THE WARM AIR EXCHANGE HOSES MUST VENT INSIDE THE ROOM WHEN USING DEHUMIDIFY MODE, NOT OUTSIDE AS IT DOES WHEN COOLING. FAN: NOTE: During Fan Mode, the exhaust hose does NOT have to be vented outdoors. 1) Press the POWER SWITCH key pad to switch the unit on (Fig. A). 2) Press the MODE key (Fig. B) until the FAN indicator illuminates on the control panel (Fig. C). Each press of the MODE key will advance to a differentmode setting (Cool-Dehumidifier-Fan). Fig. A Fig. B Fig. C Fig. E Fig. F Fig. D1 Fig. D2 IMPORTANT: The drain hose must be installed during dehumidifier mode. Drain Hose (79” / 200cm) Fig. G 3) Press the FAN Key (Fig. E) to select the desired FAN SPEED setting. Your selection will appear on the control panel. Each press of the fan key will advance to a different fan speed (High- Med-Low) as shown in Fig. F. 6 OPERATION (cont’d) AUTO-TIMER The AUTO-TIMER feature offers a unique selection of multiple choice, fully automatic on and/or off (start/stop) programs between 1-24 hours under any one mode of your Home Comfort unit. The programs are as follows:turn the unit ON / OFF automatically at specified a) Auto-Off: Pre-select a time that will turn off the times (between 1-12hrs). unit automatically (between 1-12hrs). Note: These functions must be performed daily, asb) Auto-On: Pre-select a time that will turn on the the program is automatically canceled/erased after theunit automatically (between 1-12hrs). program has ended. c) Auto-On & Auto Off: Pre-select a time that will REMOTE CONTROL FEATURES Control Buttons: 1) Power Switch 2) Mode 3) Fan Speed 4) On / Off Timer 5) Time / Temperature Set • Used for adjusting the timer and temperature. • The default display on control panel is room temperature. • When or key is pressed in cool mode, the set temperature is displayed and may be adjusted. After 10 seconds, the display will revert back to room temperature. • Timer setting is available from 1-24 hours by pressing or keys. To operate the hand held remote control you will require two “AAA” Alkaline batteries (included). Batteries should be replaced when: a) No signal (beep) is heard when attempting to program the main unit. b) The main unit does not respond to a command issued by the remote control. Battery replacement: 1) Slide the rear cover on the remote in the direction of the arrow. Continue pulling (gently) until the cover separates co...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien