Anleitung Frigidaire, modell 220250d396
Hersteller: Frigidaire Dateigröße: 673.05 kb Dateiname: 74daebdd-0179-4b29-ba58-8423d701997f.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Just follow the instructions above in the order that you require. When programmed, you will see both timer indicators lit. TEMPERATURE DISPLAY: The display can be changed to read either Fahrenheit (oF), or Celsius (oC). To do this simply hold the “ ” Temp buttons for three seconds. Note: the remote can only display the temperature in Fahrenheit (oF). 8 SZ000373(En)-YaoKong(p6-11) 8 2004.11.8, 4:02 PM Air Conditioner Features (continued) ADDITIONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with. • The “Cool” circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time. • The control will maintain the set temperature within 2oF, between 60oF and 90oF (16oC and 32oC). • The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other and back, press and hold the “TEMP” Up ( ) and Down ( ) buttons together for 3 seconds. CARE & CLEANING Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. • Pull open the filter cover by grasping the handle at the bottom. • Remove the filter. •Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. •Or, instead of washing you may vacuum the filter clean. Cabinet Cleaning • Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. • Never use harsh cleaners, wax or polish on the cabinet front. • Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. • Plug in air conditioner. Winter Storage If you plan to store the appliance during the winter, cover it with plastic or return it to its carton. 10 SZ000373(En)-YaoKong(p6-11) 10 2004.11.8, 4:02 PM Before calling for service, review this list. It may save you time and expense. This list Avoid Service Checklist includes common occurrences that are not the result of defective workmanship or materials in this appliance. OCCURRENCE SOLUTION Air conditioner will not operate. Wall plug disconnected. Push plug firmly into wall outlet. Plug Current Device Tripped. Press the RESET button. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Control is OFF. Turn Control ON and set to desired setting. Bucket Full. Drain water as described in Drainage Section. Shut off in Heat mode. When the air outlet exceeds 158°F (70°C), the automatic heat protection engages. Romove any blockages and let appliance cool down. Room Temperature lower than the set temperature (Cool Mode). Reset the temperature. Room Temperature higher than the set temperature (Heat Mode). Reset the temperature. Air from unit does not feel cold Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 60°F (16°C). enough. Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil. Reset to a Lower temperature. Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode. Air conditioner cooling, but room is too warm - ice forming on cooling coil behind rear cover. Outdoor temperature below 60°F (18°C). To defrost the coil, set FAN ONLY Mode. Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY Mode. Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN ONLY Mode. Then, set Temperature to a Higher setting. Exhaust duct not connected or blocked. See EXHAUSTING HOT AIR Section. Air conditioner cooling, but room is too warm - NO ice forming on cooling coil behind decorative front. Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section. Temperature is set too high. Set temperature to a lower setting. Air directional louvers positioned improperly. Position louvers for better air distribution. Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit. Doors, windows, registers, etc. open - cold air escapes. Close doors, windows, registers, etc. Unit recently turned on in hot room...