Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Frigidaire, modell 220201d011

Hersteller: Frigidaire
Dateigröße: 2.27 mb
Dateiname: da7f60c4-f0b1-41f1-bca5-f28da4369f86.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Exchange air from the room and draws fresh air into the room - Vent and Exhaust Open (see Fig. 3) Figure 1 (VENT CLOSED) Figure 2 (VENT OPEN) Figure 3 (VENT & EXHAUST OPEN) 10 SZ000302(En)-YaoKong(1018) 10 10/25/2004, 2:33 PM Air Conditioner Features (continued) (8-WAY) AUGER WHEELS Air Directional Louvers Air directional louvers control air flow direction. Your air conditioner has the louver type described below. Auger Type The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed. Rotate the Auger Wheels until the desired Left/Right direction is obtained. Pivot horizontal louvers until the desired Up/Down direction is obtained. Care and Cleaning Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. • Push the vent handle to the Vent Closed position (where applicable). • Open the front panel. • Grasp the filter by the center and pull up and out. • Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry before replacing. • Or, instead of washing you may vacuum the filter clean. Cabinet Cleaning • Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. • Never use harsh cleaners, wax or polish on the cabinet front. • Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. • Plug in air conditioner. Winter Storage If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton. 11 SZ000302(En)-YaoKong(1018) 11 10/25/2004, 2:33 PM Before calling for service, review this list. It may save you time and expense. This list Avoid Service Checklist includes common occurrences that are not the result of defective workman-ship or materials in this appliance. OCCURRENCE SOLUTION Air conditioner will not operate. Wall plug disconnected. Push plug firmly into wall outlet. Plug Current Device Tripped. Press the RESET button. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Control is OFF. Turn Control ON and set to desired setting. Air from unit does not feel cold Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 60°F (16°C). enough. Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil. Reset to a Lower temperature. Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode. Air conditioner cooling, but room is Outdoor temperature below 60°F (18°C). To defrost the coil, set FAN ONLY Mode. too warm - ice forming on cooling Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY Mode. coil behind decorative front. Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN ONLY Mode. Then, set Temperature to a Higher setting. Air conditioner cooling, but room is Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section. too warm - NO ice forming on Temperature is set too High. Set temperature to a Lower setting. cooling coil behind decorative front. Air directional louvers positioned improperly. Position louvers for better air distribution. Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit. Doors, windows, registers, etc. open - cold air escapes. Close doors, windows, registers, etc. Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and furniture. Air conditioner turns on and off Dirty air filter - air restricted. Clean air filter. rapidly. Outside temperature extremely hot. Set FAN speed to a faster setting to bring air past cooling coils more frequently. Noise when unit is cooling. Air movement sound. This is normal. If too loud, set to a slower FAN setting. Window vibration - poor installation. Refer to installation instructions or check with installer. Water dripping INSIDE when unit is Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation cooling. instructions - check with installer. Water dripping OUTSIDE when unit Unit removing la...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien