Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Frigidaire, modell 220201d052

Hersteller: Frigidaire
Dateigröße: 1.4 mb
Dateiname: c6736ee0-4c28-426b-92ad-c67f154815cc.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. • Never use harsh cleaners, wax or polish on the cabinet front. • Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. • Plug in air conditioner. Winter Storage If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton. • Do not block air flow inside with blinds, curtains or furniture; or outside with shrubs, Energy Saving Ideas enclosures, or other buildings. • The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation. • Install the room air conditioner on the shady side of your home. A window that faces north is best because it is shaded most of the day. • Close the fireplace damper, floor and wall registers so cool air does not escape up the chimney and into the duct work. • Keep blinds and drapes in other windows closed during the sunniest part of the day. • Clean the air filter as recommended in the section “Care and Cleaning.” • Proper insulation and water stripping in your home will help keep warm air out and cool air in. • External house shading with trees, plants or awnings will help reduce the air conditioner’s work load. • Operate heat producing appliances such as ranges, washers, dryers and dishwashers during the coolest part of the day. 11 SZ000705(En)-YaoKong 11 09/2/2005, 2:20 PM Before calling for service, review this list. It may save you time and expense. This list Avoid Service Checklist includes common occurrences that are not the result of defective workman-ship or materials in this appliance. OCCURRENCE SOLUTION Air conditioner will not operate. Wall plug disconnected. Push plug firmly into wall outlet. Plug Current Device Tripped. Press the RESET button. House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Control is OFF. Turn Control ON and set to desired setting. Air from unit does not feel cold Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 60°F (16°C). enough. Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil. Reset to a Lower temperature. Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode. Air conditioner cooling, but room is Outdoor temperature below 60°F (18°C). To defrost the coil, set FAN ONLY Mode. too warm - ice forming on cooling Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY Mode. coil behind decorative front. Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN ONLY Mode. Then, set Temperature to a Higher setting. Air conditioner cooling, but room is Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section. too warm - NO ice forming on Temperature is set too High. Set temperature to a Lower setting. cooling coil behind decorative front. Air directional louvers positioned improperly. Position louvers for better air distribution. Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit. Doors, windows, registers, etc. open - cold air escapes. Close doors, windows, registers, etc. Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and furniture. Air conditioner turns on and off Dirty air filter - air restricted. Clean air filter. rapidly. Outside temperature extremely hot. Set FAN speed to a faster setting to bring air past cooling coils more frequently. Noise when unit is cooling. Air movement sound. This is normal. If too loud, set to a slower FAN setting. Window vibration - poor installation. Refer to installation instructions or check with installer. Water dripping INSIDE when unit is Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation cooling. instructions - check with installer. Water dripping OUTSIDE when unit Unit removing large quantity of moisture from humid room. This is normal during excessively humid days. is cooling. Remote Sensing Deactivating • Remote control not located within range. Place remote control within 20 feet & 180°, radius of the front of thePrematurely (Some Models). unit. • Remote control signal obstructed. Remove obstruction. Room Too Cold. • Set temperature too low. Increase set temperature. • Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote control or deactivate remote sensing. If These Solutions...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien