Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Hisense Group, modell KFR 28GWE

Hersteller: Hisense Group
Dateigröße: 211.31 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Some radio equipment may cause maIfunction of the unit. If the troubIe happens, disconnect power and restart the air conditioner after a few minutes. REMOTE CONTROL receiver This section picks up infrared signals from the remote control unit (transmitter) POWER lamp This lamp lights when the air conditioner is in the operation mode.(But the compressor may not run at this time.) TIMER lamp This lamp lights when the system is being controlled by the timer. OPERATING lamp This lamp lights when the outdoor unit is electrified. HIPOWER lamp This lamp lights when the air conditioner run efficiently. ON/OFF button This button is set for emergent state.Please use the remote control unit to operate the air conditioner in the common state. If you have lost the remote control unit or it has trouble, use this button to turn on/off you air conditioner.(See operation without the remote control unit.) 4 • 3.Introduction of Display Displayed when one-hour-OFF timer is enable Displayed when setting timer (AUTffl SET TEMP jiHOURO HOUR ONO loffo Displayed when setting temperature Displayed when transmitting data Displayed when temperature is shown Displayed when temperature setting is at the upper or lower allowable limits Displayed when Night Setback is running Displayed when main unit sensor is in use Symbols (1) Operation mode AUTO............... COOL............... HEAT............... MILD DRY FAN ................. (2) Fan speed Automatic operation HIGH...................... MEDIUM LOW [AUTO LE run r*n CMD (3) Set temperature ' ' 16-30C When set to 28C Current temperature indication................ (4) Timer 12-hour ON Timer...... 12-hour OFF Timer 1-hour OFF Timer....... (5) NIGHT SETBACK (6) Confirmation of transmission (7) Flap angle indication (8) Sweep indication........ (9) Indoor unit sensor....... EB ID [ÍOFF011 1H0UR© © vr\ C 5 • 4.Introduction of the Remote control Unit SENSOR- Transmitter 1 HR. TIMER button HIGH POWER button FLAP buttonTIMER ON/OFF button TIMER SET/CANCEL - button A/C SENSOR button- AI A, SET TEMP 'Ä c ù#-H I QiR _I immi 1HOUR§) , _. HOUR .—I [ÔN©] ' [OI 1HR 0 TEMP ON/OFF fA] © - Display -TEMP.setting button - ON/OFF button ■ MODE selector button FAN SPEED selector button NIGHT SETBACK button ACL button © o (Cover closed) HIGH POWER Battery compartment (pull off the cover to expose the batteries.) NOTE The illustration above pictures the remote control unit after the cover has been lowered and removed. Transmitter When you press the buttons on the remote control unit,the ^ mark appears in the display to transmit the setting changes to the receiver in the air conditioner. SENSOR A temperature sensor inside the remote control unit senses the room temperature. Display Information on the operating conditions is displayed while the remote control unit is switched on. If the unit is turned off, only the mode that was set previously is still displayed. SLEEP button For details, see "Night Setback Mode” . When you press this button, in the HEAT, DRY or COOL mode, the (^) mark appears in the display, the remote control unit will automatically adjust the set temperature to save energy. TEMP. Setting buttons Press the A button to increase the set temperature. Press the v button to reduce the set temperature. ON/OFF operation button This button is for turning the air conditioner on and off. 6 • Remote Control Unit(continued) TIMER ON button 1 on Q | :The air conditioner starts at the set time. TIMER OFF button (off©) :The air conditioner stops at the set time. TIMER SET/CANCEL button This button is used to set/cancel the time at which you wish the air conditioner to go on or off. MODE selector button (AUTO) (HEAT) (DRY) (COOL) (FAN) Use this button to select AUTO, HEAT DRY or COOL mode. (AutO) :When this setting is selected, the air conditioner calculates the difference between the set thermostat and the room temperature and automatically switches to the "COOL" or "HEATI" mode appropriately. :The air conditioner makes the room warm. d :The air conditioner reduces the humidity in the room. ^ :The air conditioner makes the room cool. H :The air conditioner makes the room's temperature suitable. FLAP button Press this button either to select to set the airflow direction to one of the six possible positions manually, or to select the sweep function, which moves the flap up and down automatically. ||', :The airflow direction can be set manually.(six positions) (^ :The flap moves up and down automatically. (gT}l :Press the FLAP button and set the airflow directions as desired. (refer to Adjust the Airflow Direction). FAN SPEED selector button ® :The air conditioner automatically decides the fan speeds. )) : High fan speed. ) :Medium fan speed. :Low fan speed. 1 HR TIMER button (1-HOUR OFF TIMER) K&) :When you press this button, regardless of whether the unit is operating or stopping, the unit operates for ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - KFR 2101GWE (211.31 kb)
Splitgeräte - KFR 3201GWE (211.31 kb)
Splitgeräte - KFR 33GWE (211.31 kb)
Splitgeräte - KFR 25GWE (211.31 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien